The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
A multilayered microfluidic blood vessel-like structure
Open accessAbstract
There is an immense need for tissue engineered blood vessels. However, current tissue engineering approaches still lack the ability to build native blood vessel-like perfusable structures with multi-layered vascular walls. This paper demonstrated a new method to fabricate tri-layer biomimetic blood vessel-like structures on a microfluidic platform using photocrosslinkable gelatin hydrogel. The presented method enables fabrication of physiological blood vessel-like structures with mono-, bi- or tri-layer vascular walls. The diameter of the vessels, the total thickness of the vessel wall and the thickness of each individual layer of the wall were independently controlled. The developed fabrication process is a simple and rapid method, allowing the physical fabrication of the vascular structure in minutes, and the formation of a vascular endothelial cell layer inside the vessels in 3-5 days. The fabricated vascular constructs can potentially be used in numerous applications including drug screening, development of in vitro models for cardiovascular diseases and/or cancer metastasis, and study of vascular biology and mechanobiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell-laden microengineered gelatin methacrylate hydrogels
Nichol, J. W., Koshy, S. T., Bae, H., Hwang, C. M., Yamanlar, S., & Khademhosseini, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.064 · Cited by 2,377
Self-citationRapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Structural and Rheological Properties of Methacrylamide Modified Gelatin Hydrogels
Van Den Bulcke, A. I., Bogdanov, B., De Rooze, N., Schacht, E. H., Cornelissen, M., & Berghmans, H. (2000) · Biomacromolecules · doi:10.1021/bm990017d · Cited by 1,536
Vascularization is the key challenge in tissue engineering
Novosel, E. C., Kleinhans, C., & Kluger, P. J. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.03.004 · Cited by 1,067
In vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
Functional Human Vascular Network Generated in Photocrosslinkable Gelatin Methacrylate Hydrogels
Chen, Y., Lin, R., Qi, H., Yang, Y., Bae, H., Melero‐Martin, J. M., & Khademhosseini, A. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201101662 · Cited by 802
Self-citationElectrospun scaffolds for tissue engineering of vascular grafts
Hasan, A., Memić, A., Annabi, N., Hossain, M., Paul, A., Dokmeci, M. R., Dehghani, F., & Khademhosseini, A. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.08.022 · Cited by 739
Self-citationFormation of perfused, functional microvascular tubes in vitro
Chrobak, K. M., Potter, D. R., & Tien, J. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.02.005 · Cited by 555
Paul, A., Hasan, A., Kindi, H. N. A., Gaharwar, A. K., Rao, V. T. S., Nikkhah, M., Shin, S. R., Krafft, D., Dokmeci, M. R., Shum‐Tim, D., et al. (2014) · ACS Nano · doi:10.1021/nn5020787 · Cited by 540
Self-citationCell migration into scaffolds under co-culture conditions in a microfluidic platform
Chung, S. H., Sudo, R., Mack, P. J., Wan, C.-R., Vickerman, V., & Kamm, R. D. (2008) · Lab on a Chip · doi:10.1039/b807585a · Cited by 530
Cited by
Sorted by citations
Park, S. E., Georgescu, A., & Huh, D. (2019) · Science · doi:10.1126/science.aaw7894 · Cited by 847
Nanoparticles in tissue engineering: applications, challenges and prospects
Hasan, A., Morshed, M., Memić, A., Hassan, S., Webster, T. J., & Marei, H. E. S. (2018) · International Journal of Nanomedicine · doi:10.2147/ijn.s153758 · Cited by 498
Self-citationHerland, A., van der Meer, A. D., Fitzgerald, E. A., Park, T., Sleeboom, J. J. F., & Ingber, D. E. (2016) · PLoS ONE · doi:10.1371/journal.pone.0150360 · Cited by 496
Precise Tuning of Facile One-Pot Gelatin Methacryloyl (GelMA) Synthesis
Shirahama, H., Lee, B. H., Tan, L. P., & Cho, N. (2016) · Scientific Reports · doi:10.1038/srep31036 · Cited by 477
Multiscale bioprinting of vascularized models
Miri, A. K., Khalilpour, A., Çeçen, B., Maharjan, S., Shin, S. R., & Khademhosseini, A. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.08.006 · Cited by 277
Self-citation
Metadata
- Authors
- Hasan, A., Paul, A., Memic, A., & Khademhosseini, A.
- Affiliations
- American University of Beirut (LB)
- Brigham and Women's Hospital (US)
- Corresponding author
- Hasan, Anwarul
- Khademhosseini, Ali
- Venue
- Biomedical Microdevices
- Published
- 2015-08-11
- Volume
- 17
- Issue
- 5
- Pages
- 88-88
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- PMC
- PMC4890640
- OpenAlex
- W1436031433
- Cited by
- 139
- References
- 41
- Citations by year
- 2026: 5 · 2025: 3 · 2024: 13 · 2023: 21 · 2022: 15 · 2021: 17 · 2020: 9 · 2019: 13 · 2018: 18 · 2017: 15 · 2016: 9
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
- KU ScholarWorks (The University of Kansas) (submittedVersion)
- Springer US
- Funders
- National Heart, Lung, and Blood Institute (HL-099073, R01HL099073)
- National Institute of General Medical Sciences (P20GM103638)
- National Institute of Allergy and Infectious Diseases (R56AI105024, AI105024)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR057837, R01AR057837, R56AR063745, AR063745)
- National Institute of Biomedical Imaging and Bioengineering (R01EB012597, EB012597)
- National Institute of Dental and Craniofacial Research (DE021468, R01DE021468)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Keywords
- tissue-engineered blood vessels, drug screening, cardiovascular disease models, mechanobiology
- MeSH terms
- Blood Vessel Prosthesis, Cells, Cultured, Equipment Design, Humans, Miniaturization, Equipment Failure Analysis, Tissue Engineering, Biomimetic Materials, Endothelial Cells, Microfluidics, Tissue Scaffolds, Printing, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review