Which Reference Should We Use for EEG and ERP practice?
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
Which reference is appropriate for the scalp ERP and EEG studies? This unsettled problem still inspires unceasing debate. The ideal reference should be the one with zero or constant potential but unfortunately it is well known that no point on the body fulfills this condition. Consequently, more than ten references are used in the present EEG-ERP studies. This diversity seriously undermines the reproducibility and comparability of results across laboratories. A comprehensive review accompanied by a brief communication with rigorous derivations and notable properties (Hu et al. Brain Topogr, 2019. https://doi.org/10.1007/s10548-019-00706-y ) is thus necessary to provide application-oriented principled recommendations. In this paper current popular references are classified into two categories: (1) unipolar references that construct a neutral reference, including both online unipolar references and offline re-references. Examples of unipolar references are the reference electrode standardization technique (REST), average reference (AR), and linked-mastoids/ears reference (LM); (2) non-unipolar references that include the bipolar reference and the Laplacian reference. We show that each reference is derived with a different assumption and serves different aims. We also note from (Hu et al. 2019) that there is a general form for the reference problem, the 'no memory' property of the unipolar references, and a unified estimator for the potentials at infinity termed as the regularized REST (rREST) which has more advantageous statistical evidence than AR. A thorough discussion of the advantages and limitations of references is provided with recommendations in the hope to clarify the role of each reference in the ERP and EEG practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Cited by 5,977
Über das Elektrenkephalogramm des Menschen
Berger, H. (1929) · Archiv für Psychiatrie und Nervenkrankheiten · doi:10.1007/bf01797193 · Cited by 4,235 · cited 2×
“Since the first report of the human EEG in 1929 (Berger 1929; Gloor 1969), the reference issue has long been debated and Berger had called attention to the reference issue at the very beginning.”
BackgroundElectroencephalography—Basic principles, clinical applications and related fields
(1982) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(82)90067-4 · Cited by 3,427
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Spherical splines for scalp potential and current density mapping
Perrin, F., Pernier, J., Bertrand, O., & Echallier, J. F. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90180-6 · Cited by 2,706
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
An on-line transformation of EEG scalp potentials into orthogonal source derivations
Hjorth, B. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90056-5 · Cited by 1,012 · cited 10×
“(1), SL is an estimate of the current source density (CSD) (Hjorth 1975; Yao 2002a).”
BackgroundMethodInfluentialInformation Criteria and Statistical Modeling
Konishi, S., & Kitagawa, G. (2008) · Springer Series in Statistics · doi:10.1007/978-0-387-71887-3 · Cited by 959
Robert, C. P. (1994) · Springer Texts in Statistics · doi:10.1007/978-1-4757-4314-2 · Cited by 744
Considerations of quasi-stationarity in electrophysiological systems
Plonsey, R., & Heppner, D. B. (1967) · The Bulletin of Mathematical Biophysics · doi:10.1007/bf02476917 · Cited by 619
A method to standardize a reference of scalp EEG recordings to a point at infinity
Yao, D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/305 · Cited by 576 · cited 6×
“It is clear that any solution to the EEG reference problem must be based on volume conduction thus transforming it into a physically spatial inference problem (Yao 2001; Hu et al.”
BackgroundMethodInfluentialSelf-citationTHE ELECTRO-ENCEPHALOGRAM IN EPILEPSY AND IN CONDITIONS OF IMPAIRED CONSCIOUSNESS
GIBBS, F. A. (1935) · Archives of Neurology And Psychiatry · doi:10.1001/archneurpsyc.1935.02250240002001 · Cited by 571
A theoretical justification of the average reference in topographic evoked potential studies
Bertrand, O., Perrin, F., & Pernier, J. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90058-9 · Cited by 416
Common reference coherence data are confounded by power and phase effects
Fein, G., Raz, J., Brown, F. F., & Merrin, E. L. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90171-x · Cited by 287
Electroencephalography, Basic Principles, Clinical Applications and Related Fields
Walker, A. E. (1982) · The Journal of Nervous and Mental Disease · doi:10.1097/00005053-198211000-00020 · Cited by 271
MATLAB Toolboxes for Reference Electrode Standardization Technique (REST) of Scalp EEG
Dong, L., Li, F., Liu, Q., Wen, X., Lai, Y., Xu, P., & Yao, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00601 · Cited by 228
Self-citationBioelectricity and biomagnetism
Gulrajani, R. M. (1998) · Cited by 217
Qin, Y., Xu, P., & Yao, D. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.03.056 · Cited by 209
Self-citationFinite-element model of the human head: scalp potentials due to dipole sources
Yan, Y., Nunez, P. L., & Hart, R. T. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442317 · Cited by 208
MEG Signatures of a Perceived Match or Mismatch between Individual and Group Opinions
Zubarev, I., Klucharev, V., Ossadtchi, A., Moiseeva, V., & Shestakova, A. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00010 · Cited by 181
Tenke, C. E., & Kayser, J. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.08.007 · Cited by 176
The FieldTrip-SimBio pipeline for EEG forward solutions
Vorwerk, J., Oostenveld, R., Piastra, M. C., Magyari, L., & Wolters, C. H. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0463-y · Cited by 172
Yao, D., Wang, L., Oostenveld, R., Nielsen, K. D., Arendt-Nielsen, L., & Chen, A. C. N. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/3/003 · Cited by 172
Self-citationBabiloni, F., Cincotti, F., Carducci, F., Rossini, P. M., & Babiloni, C. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00494-1 · Cited by 164
Correlation and coherence analysis of the EEG: A selective tutorial review
Shaw, J. C. (1984) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90045-x · Cited by 162 · cited 1×
“1988), confounding the interpretation of results (Shaw 1984; Travis 1994).”
BackgroundSuzuki, J. (1986) · Springer eBooks · doi:10.1007/978-3-642-95483-2_5 · Cited by 155
The EEG as potential mapping: The value of the average monopolar reference
Offner, F. F. (1950) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(50)90040-x · Cited by 147 · cited 2×
“In contrast, inspired from the Wilson common terminal reference in EKG, AR was reported in (Goldman 1950; Offner 1950); and there was a theoretical proof confirming the surface potential integral of a layered spherical sphere being zero (Bertrand et al.”
BackgroundMethodImpact of the reference choice on scalp EEG connectivity estimation
Chella, F., Pizzella, V., Zappasodi, F., & Marzetti, L. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036016 · Cited by 140
Stone, J. L., & Hughes, J. R. (2013) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31827edb2d · Cited by 129
The Time-Varying Networks in P300: A Task-Evoked EEG Study
Li, F., Chen, B., Li, H., Zhang, T., Wang, F., Jiang, Y., Li, P., Ma, T., Zhang, R., Tian, Y., et al. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2523678 · Cited by 124
Self-citationLiu, Q., Balsters, J. H., Bächinger, M., van der Groen, O., Wenderoth, N., & Mantini, D. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056012 · Cited by 119
Epilepsy Surgery: Historical Highlights 1909–2009
Feindel, W., Leblanc, R., & de Almeida, A. N. (2009) · Epilepsia · doi:10.1111/j.1528-1167.2009.02043.x · Cited by 114
How do reference montage and electrodes setup affect the measured scalp EEG potentials?
Hu, S., Lai, Y., Valdes-Sosa, P. A., Bringas-Vega, M. L., & Yao, D. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa13f · Cited by 109
Self-citationThe use of standardized infinity reference in EEG coherency studies
Marzetti, L., Nolte, G., Perrucci, M. G., Romani, G. L., & Gratta, C. D. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.034 · Cited by 91
REST: A good idea but not the gold standard
Nunez, P. L. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.04.029 · Cited by 80 · cited 4×
“Whether the electrode density is high enough to approximate the theoretical integral (Nunez 2010)?”
BackgroundResultInfluentialHans Berger on Electroencephalography
GLOOR, P. (1969) · American Journal of EEG Technology · doi:10.1080/00029238.1969.11080728 · Cited by 71 · cited 1×
“Since the first report of the human EEG in 1929 (Berger 1929; Gloor 1969), the reference issue has long been debated and Berger had called attention to the reference issue at the very beginning.”
BackgroundYao, D. (2017) · Brain Topography · doi:10.1007/s10548-016-0543-x · Cited by 71
Self-citationFaux, S. F., Shenton, M. E., McCarley, R. W., Nestor, P. G., Marcy, B., & Ludwig, A. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90083-v · Cited by 69
Why do we need to use a zero reference? Reference influences on the ERPs of audiovisual effects
Tian, Y., & Yao, D. (2013) · Psychophysiology · doi:10.1111/psyp.12130 · Cited by 67
Self-citationPascual-Marqui, R. D., & Lehamann, D. (1993) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(93)90043-o · Cited by 66
Electric potential produced by a dipole in a homogeneous conducting sphere
Yao, D. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846691 · Cited by 66 · cited 5×
“One may take a closed distributed dipole layer with all actual sources inside as the equivalent sources (Yao 2000b; Yao and He 2003).”
BackgroundMethodInfluentialSelf-citationXu, P., Xiong, X., Xue, Q., Tian, Y., Peng, Y., Zhang, R., Li, P. Y., Wang, Y., & Yao, D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/1279 · Cited by 56
Self-citationMultimodal Quantitative Neuroimaging Databases and Methods: The Cuban Human Brain Mapping Project
Hernández-González, G., Bringas-Vega, M. L., Galán‐Garcia, L., Bosch‐Bayard, J., Lorenzo, Y., Melie‐García, L., Valdés-Urrutia, L., Ruíz, M. C., Valdes-Sosa, P. A., & Cuban Human Brain Mapping Project (CHBMP) (2011) · Clinical EEG and Neuroscience · doi:10.1177/155005941104200303 · Cited by 52
Self-citationHigh-resolution EEG mappings: a spherical harmonic spectra theory and simulation results
Dezhong, Y. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00205-9 · Cited by 52
The History of EEG Hans Berger
Vaque, T. J. L. (1999) · Journal of Neurotherapy · doi:10.1300/j184v03n02_01 · Cited by 50
The Statistics of EEG Unipolar References: Derivations and Properties
Hu, S., Yao, D., Bringas-Vega, M. L., Qin, Y. F., & Valdes-Sosa, P. A. (2019) · Brain Topography · doi:10.1007/s10548-019-00706-y · Cited by 47
Self-citationBonfiglio, L., Olcese, U., Rossi, B., Frisoli, A., Arrighi, P., Greco, G., Carozzo, S., André, P., Bergamasco, M., & Carboncini, M. C. (2012) · Human Brain Mapping · doi:10.1002/hbm.22056 · Cited by 46
Kugiumtzis, D., & Kimiskidis, V. Κ. (2015) · International Journal of Neural Systems · doi:10.1142/s0129065715500069 · Cited by 44
Non-linear Analysis of Scalp EEG by Using Bispectra: The Effect of the Reference Choice
Chella, F., D’Andrea, A., Basti, A., Pizzella, V., & Marzetti, L. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00262 · Cited by 39
Hu, S., Yao, D., & Valdes-Sosa, P. A. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00297 · Cited by 37
Self-citationHow Different EEG References Influence Sensor Level Functional Connectivity Graphs
Huang, Y., Zhang, J., Cui, Y., Yang, G., He, L., Liu, Q., & Yin, G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00368 · Cited by 36
High-resolution EEG mapping: a radial-basis function based approach to the scalp Laplacian estimate
Yao, D. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00053-6 · Cited by 27 · cited 6×
“…if the scalp layer of human head model as a cubic element, (17) ixy = 2 (n,m) r x2 + 2 (n,m) r y2 ∝ ( (n+1,m) r + (n−1,m) r + (n,m+1) r + (n,m−1) r − 4 (n,m) r ) 1 3 SL will be an estimate of local current density/flux (CD) through the skull into the scalp (Yao 2002a; Nunez and Srinivasan 2006).”
BackgroundInfluentialSelf-citationThe Scalp Time-Varying Networks of N170: Reference, Latency, and Information Flow
Tian, Y., Xu, W. L., Zhang, H., Tam, K. Y., Zhang, H., Li, Y., Li, Z., & Pang, Y. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00250 · Cited by 21
A Comparative Study on the Dynamic EEG Center of Mass with Different References
Qin, Y. F., Xin, X., Zhu, H., Li, F., Xiong, H., Zhang, T., & Lai, Y. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00509 · Cited by 18
Self-citationHuang, X., Long, Z., & Lei, X. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.09.017 · Cited by 17
Yao, D. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/12/312 · Cited by 16 · cited 6×
“…if the scalp layer of human head model as a cubic element, (17) ixy = 2 (n,m) r x2 + 2 (n,m) r y2 ∝ ( (n+1,m) r + (n−1,m) r + (n,m+1) r + (n,m−1) r − 4 (n,m) r ) 1 3 SL will be an estimate of local current density/flux (CD) through the skull into the scalp (Yao 2002a; Nunez and Srinivasan 2006).”
BackgroundInfluentialSelf-citationScalp Current Density Mapping in the Analysis of Mismatch Negativity Paradigms
Giard, M., Besle, J., Aguera, P., Gomot, M., & Bertrand, O. (2013) · Brain Topography · doi:10.1007/s10548-013-0324-8 · Cited by 16
A Comparative Study of Different EEG Reference Choices for Diagnosing Unipolar Depression
Mumtaz, W., & Malik, A. S. (2018) · Brain Topography · doi:10.1007/s10548-018-0651-x · Cited by 15
A Second Linked-Reference Issue: Possible Biasing of Power and Coherence Spectra
Travis, F. T. (1994) · International Journal of Neuroscience · doi:10.3109/00207459408986294 · Cited by 13 · cited 1×
“1988), confounding the interpretation of results (Shaw 1984; Travis 1994).”
BackgroundRestate the reference for EEG microstate analysisPreprint
Hu, S., Karahan, E., & Valdes-Sosa, P. A. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1802.02701 · Cited by 11 · cited 24×
“The reference operator in (3) for unipolar references (Hu et al. 2018b) is commonly as, where 1 is a vector of ones; N c is an identity matrix; r ∈ R N c × 1 consists of the linear combination weights of all the electrodes.”
BackgroundMethodInfluentialSelf-citation
Cited by
Summary of over Fifty Years with Brain-Computer Interfaces—A Review
Kawala-Sterniuk, A., Browarska, N., Al-Bakri, A., Pelc, M., Zygarlicki, J., Sidikova, M., Martinek, R., & Gorzelanczyk, E. J. (2021) · Brain Sciences · doi:10.3390/brainsci11010043 · Cited by 292
Connectivity Analysis in EEG Data: A Tutorial Review of the State of the Art and Emerging Trends
Chiarion, G., Sparacino, L., Antonacci, Y., Faes, L., & Mesin, L. (2023) · Bioengineering · doi:10.3390/bioengineering10030372 · Cited by 195
“This type of recordings acts as a high-pass filter, making it more affected by random noise and less sensitive to signals from deep neural sources but more stable to common-mode interference and selective of focal activities [299].”
BackgroundVoetterl, H., van Wingen, G., Michelini, G., Griffiths, K. R., Gordon, E., DeBeus, R., Korgaonkar, M. S., Loo, S. K., Palmer, D., Breteler, R., et al. (2023) · Biological Psychiatry: Cognitive Neuroscience and Neuroimaging · doi:10.1016/j.bpsc.2022.02.007 · Cited by 35
Shao, C., Li, D., Zhang, X., Xiang, F., Zhang, X., & Wang, X. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2023.1326841 · Cited by 5
Metadata
- Authors
- Yao, D., Qin, Y., Hu, S., Dong, L., Bringas Vega, M. L., & Valdés Sosa, P. A.
- Venue
- Brain Topography
- Published
- 2019-04-29
- Volume
- 32
- Issue
- 4
- Pages
- 530-549
- ISSN
- 0896-0267 (ISSN-L)
- 1573-6792
- OpenAlex
- W2942905092
- Cited by
- 191
- References
- 62
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.