Monitoring pH and dissolved oxygen in mammalian cell culture using optical sensors
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Here, we have studied two parameters critical to process control in mammalian cell culture; dissolved oxygen (dO(2)) and pH, measured with fluorescent sensors thus allowing the study of the metabolic state of cells in culture without removing or damaging cells during cultivation. Two cell lines, namely, NS0 and CHO were batch-grown in 24-well plates at different serum concentrations with the sensors implemented in the bottom of each well. The data showed a good relationship between the dO(2) and pH data obtained from fluorescent probes and the growth and death characteristics of cells. The method has provided a high throughput on-line multi-parametric analysis of mammalian cell cellular activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While this phenomenon has so far not been reported in spheroid systems prior to this study, the hypothesis is supported by other studies that noted a similar trend of increase in dissolved oxygen level in monolayer cultures which were correlated with an increase in cell death attributed to lack of nutrients [53], but the precise mechanism as yet remains unclear.”
From Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry (2016) · cites this paper as [53]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, W. M., Blanch, H. W., & Wilke, C. R. (1988) · Biotechnology and Bioengineering · doi:10.1002/bit.260320803 · Cited by 476
Choi, J.-I., & Lee, S. Y. (1999) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19990305)62:5<501::aid-bit1>3.0.co;2-y · Cited by 219
Harms, P. D., Kostov, Y. V., & Rao, G. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00295-1 · Cited by 198
In‐situ near infrared spectroscopy to monitor key analytes in mammalian cell cultivation
Arnold, S. A., Crowley, J., Woods, N., Harvey, L. M., & McNeil, B. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10738 · Cited by 149
Prevention of hybridoma cell death by bcl2 during suboptimal culture conditions
Simpson, N. H., Milner, A. E., & Al‐Rubeai, M. (1997) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19970405)54:1<58::aid-bit7>3.0.co;2-x · Cited by 132
Prevention of hybridoma cell death bybcl-2 during suboptimal culture conditions
Simpson, N. H., Milner, A. E., & Al-Rubeai, M. (1997) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19970405)54:1<1::aid-bit1>3.0.co;2-k · Cited by 132
Self-citationIn-situ microscopy: Online process monitoring of mammalian cell cultures
Joeris, K., Frerichs, J.-G., Konstantinov, K., & Scheper, T. H. (2002) · Cytotechnology · doi:10.1023/a:1021170502775 · Cited by 125
Validation of an optical sensor-based high-throughput bioreactor system for mammalian cell culture
Ge, X., Hanson, M., Shen, H., Kostov, Y. V., Brorson, K., Frey, D. D., Moreira, A. R., & Rao, G. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.12.009 · Cited by 108
Ozturk, S. S., & Palsson, B. Ø. (1990) · Biotechnology Progress · doi:10.1021/bp00006a006 · Cited by 108
Hanson, M. A., Ge, X., Kostov, Y., Brorson, K. A., Moreira, A. R., & Rao, G. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21320 · Cited by 106
Cited by
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Antoine, E. E., Vlachos, P. P., & Rylander, M. N. (2014) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0086 · Cited by 611
“4, as cell viability suffers outside this range.(80,81) Achilli and Mantovani bypassed this restriction by first polymerizing hydrogels at pH = 10 and subsequently rinsing with buffer to return the pH to 7.”
Place, T. L., Domann, F. E., & Case, A. J. (2017) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2017.10.003 · Cited by 434
Astashkina, A., Mann, B., & Grainger, D. W. (2012) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2012.01.001 · Cited by 424
“Media oxygenation, oxygen depletion gradients, and cell metabolism are linked as well to media protein content (Naciri et al., 2008); cell metabolic capacities also change with protein content (vida infra), also impacting oxygen utilization.”
BackgroundMicrosensor systems for cell metabolism – from 2D culture to organ-on-chip
Kieninger, J., Weltin, A., Flamm, H., & Urban, G. A. (2018) · Lab on a Chip · doi:10.1039/c7lc00942a · Cited by 198
PDMS-Based Microfluidic Devices for Cell Culture
Torino, S., Corrado, B., Iodice, M., & Coppola, G. (2018) · Inventions · doi:10.3390/inventions3030065 · Cited by 157
Oxidative Stress Under Ambient and Physiological Oxygen Tension in Tissue Culture
Jagannathan, L., Cuddapah, S., & Costa, M. (2016) · Current Pharmacology Reports · doi:10.1007/s40495-016-0050-5 · Cited by 150
“Moreover, the actual oxygen level the cell is exposed to in a culture dish is much lower than the surrounding atmospheric levels and the O2 levels further decrease when the cells proliferate [96].”
BackgroundLee-Montiel, F. T., George, S. M., Gough, A. H., Sharma, A. D., Wu, J., DeBiasio, R., Vernetti, L. A., & Taylor, D. L. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217703978 · Cited by 141
“Media flowing into the MPS was considered to have been equilibrated with atmospheric oxygen and therefore containing 18% dissolved oxygen.(29,36,37) The simulations in all cases were run using a coarse mesh to model 18 h of flow at 1-h intervals.”
MethodTunable Collagen I Hydrogels for Engineered Physiological Tissue Micro-Environments
Antoine, E. E., Vlachos, P. P., & Rylander, M. N. (2015) · PLOS ONE · doi:10.1371/journal.pone.0122500 · Cited by 125
“4 was selected because this range supports cell viability [18,19] and several previous studies have suggested that pH can be a valuable tool for controlling hydrogel material properties [7,10,12].”
MethodMeasuring bacterial growth by refractive index tapered fiber optic biosensor
Zibaii, M. I., Kazemi, A., Latifi, H., Azar, M., Hosseini, S. M., & Ghezelayagh, M. H. (2010) · Journal of Photochemistry and Photobiology B Biology · doi:10.1016/j.jphotobiol.2010.07.017 · Cited by 128
“The results will require interpretation, and are not as clear-cut as direct measurement [5,6]”
BackgroundMethodTechnological progresses in monoclonal antibody production systems
Rodrigues, M. E., Costa, A. R., Henriques, M., Azeredo, J., & Oliveira, R. (2009) · Biotechnology Progress · doi:10.1002/btpr.348 · Cited by 146
Langan, L. M., Dodd, N. J. F., Owen, S. F., Purcell, W. M., Jackson, S. K., & Jha, A. N. (2016) · PLOS ONE · doi:10.1371/journal.pone.0149492 · Cited by 104
Oxygen levels in thermoplastic microfluidic devices during cell culture
Ochs, C. J., Kasuya, J., Pavesi, A., & Kamm, R. D. (2014) · Lab Chip · doi:10.1039/c3lc51160j · Cited by 96
Abel, S., & Baird, S. K. (2017) · Food Chemistry · doi:10.1016/j.foodchem.2017.08.083 · Cited by 98
Bioengineering Outlook on Cultivated Meat Production
Pajčin, I., Knežić, T., Azoulay, I. S., Vlajkov, V., Djisalov, M., Janjušević, L., Grahovac, J. A., & Gadjanski, I. (2022) · Micromachines · doi:10.3390/mi13030402 · Cited by 99
Fliefel, R. M., Popov, C., Troeltzsch, M., Kühnisch, J., Ehrenfeld, M., & Otto, S. (2016) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2016.03.003 · Cited by 67
“, 2010) and in cultures with high cell numbers but limited nutrients (Naciri et al., 2008); pH 7.”
BackgroundMihaila, S. M., Popa, E. G., Reis, R. L., Marques, A. P., & Gomes, M. E. (2014) · Biomacromolecules · doi:10.1021/bm500036a · Cited by 59
Bioactive polydimethylsiloxane surface for optimal human mesenchymal stem cell sheet culture
Qian, Z., Ross, D., Jia, W., Xing, Q., & Zhao, F. (2018) · Bioactive Materials · doi:10.1016/j.bioactmat.2018.01.005 · Cited by 62
Tian, Y., Shumway, B. R., Gao, W., Youngbull, C., Holl, M. R., Johnson, R. H., & Meldrum, D. R. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.08.036 · Cited by 50
Electrical Impedance Measurements of Biological Cells in Response to External Stimuli
Mansoorifar, A., Koklu, A., Ma, S., Raj, G. V., & Beşkök, A. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05392 · Cited by 52
Hwang, H. J., Lynn, S. G., Vengellur, A., Saini, Y., Grier, E. A., Ferguson-Miller, S. M., & LaPres, J. J. (2015) · Biochemistry · doi:10.1021/bi5012892 · Cited by 47
Demuth, C., Varonier, J., Jossen, V., Eibl, R., & Eibl, D. (2016) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-016-7412-0 · Cited by 52
“It is evident that single-use cultivation systems, which have been increasingly implemented in the past 15 years, have strongly influenced pH and DO sensor techniques (Hanson et al. 2007; Naciri et al. 2008; Lam and Kostov 2009; Lindner et al. 2011; Paldus and Selker 2011).”
BackgroundWalimbe, T., & Panitch, A. (2020) · Bioengineering · doi:10.3390/bioengineering7040156 · Cited by 54
A Prevalent Neglect of Environmental Control in Mammalian Cell Culture Calls for Best Practices
Klein, S. G., Alsolami, S. M., Steckbauer, A., Arossa, S., Parry, A. J., Ramos Mandujano, G., Alsayegh, K., Izpisua Belmonte, J. C., Li, M., & Duarte, C. M. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00775-0 · Cited by 41
Biosensors to Monitor Cell Activity in 3D Hydrogel-Based Tissue Models
Fedi, A., Vitale, C., Giannoni, P., Caluori, G., & Marrella, A. (2022) · Sensors · doi:10.3390/s22041517 · Cited by 48
“Many fluorescent sensors have been recently developed to allow the analysis of pH alterations at a cell-size scale [102,103], as they represent a minimally invasive sensing technology, devoid of cell-damaging effects [104].”
BackgroundBhattacharya, S., Calar, K., Evans, C. M., Petrasko, M., & de la Puente, P. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.01040 · Cited by 43
Klein, S. G., Alsolami, S. M., Arossa, S., Ramos‐Mandujano, G., Parry, A. J., Steckbauer, A., Duarte, C. M., & Li, M. (2022) · Communications Biology · doi:10.1038/s42003-022-03065-w · Cited by 40
Rizzo, R., Onesto, V., Forciniti, S., Chandra, A., Prasad, S., Iuele, H., Colella, F., Gigli, G., & del Mercato, L. L. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114401 · Cited by 40
Advances in numerical approaches for microfluidic cell analysis platforms
Sheidaei, Z., Akbarzadeh, P., & Kashaninejad, N. (2020) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2020.07.008 · Cited by 45
Influence of living cells (L929) on the biodegradation of magnesium–calcium alloy
Kannan, M. B., Yamamoto, A., & Khakbaz, H. (2015) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2015.01.015 · Cited by 33
Lorenzo‐Moldero, I., Chandra, A., Cavo, M., Mota, C., Kapsokalyvas, D., Gigli, G., Moroni, L., & del Mercato, L. L. (2020) · Small · doi:10.1002/smll.202002258 · Cited by 36
Meier, R. J., Simbürger, J. M. B., Soukka, T., & Schäferling, M. (2015) · Chemical Communications · doi:10.1039/c5cc00144g · Cited by 31
Kuystermans, D., Avesh, M., & Al‐Rubeai, M. (2014) · Cytotechnology · doi:10.1007/s10616-014-9791-3 · Cited by 29
Adaptation to inflammatory acidity through neutrophil-derived adenosine regulation of SLC26A3
Cartwright, I. M., Curtis, V. F., Lanis, J. M., Alexeev, E. E., Welch, N., Goldberg, M. S., Schaefer, R. E. M., Gao, R. Y., Chun, C. L., Fennimore, B. P., et al. (2019) · Mucosal Immunology · doi:10.1038/s41385-019-0237-2 · Cited by 30
Transient Lentiviral Vector Production Using a Packed-Bed Bioreactor System
McCarron, A., Donnelley, M., McIntyre, C., & Parsons, D. (2019) · Human Gene Therapy Methods · doi:10.1089/hgtb.2019.038 · Cited by 29
“As oxygen availability is critical for cell growth and high-titer yields, 25,26 the gassing parameters were altered with each subsequent run to improve maintenance of the 50% DO setpoint.”
InfluentialSUGIYAMA, Y., Hagiya, Y., Nakajima, M., Ishizuka, M., Tanaka, T., & Ogura, S. (2013) · Oncology Reports · doi:10.3892/or.2013.2945 · Cited by 33
“Dissolved oxygen concentrations in cultured medium were determined using a 24-channel SDR SensorDish® Reader (PreSens Precision Sensing GmbH, Regensburg, Germany), with some modifications (12).”
MethodMkilima, T. (2025) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.15352 · Cited by 35
Miedel, M. T., Gavlock, D. C., Jia, S., Gough, A., Taylor, D. L., & Stern, A. M. (2019) · Scientific Reports · doi:10.1038/s41598-019-44756-5 · Cited by 26
Toward Best Practices for Controlling Mammalian Cell Culture Environments
Klein, S. G., Steckbauer, A., Alsolami, S. M., Arossa, S., Parry, A. J., Li, M., & Duarte, C. M. (2022) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2022.788808 · Cited by 23
Current and future technologies for monitoring cultured meat: A review
Pawar, D., Presti, D. L., Silvestri, S., Schena, E., & Massaroni, C. (2023) · Food Research International · doi:10.1016/j.foodres.2023.113464 · Cited by 27
Controlled deposition of sol–gel sensor material using hemiwicking
Mikkelsen, M. B., Marie, R., Hansen, J. H., Wencel, D., McDonagh, C. M., Nielsen, H. O., & Kristensen, A. S. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/11/115008 · Cited by 21
A versatile quinoxaline derivative serves as a colorimetric sensor for strongly acidic pH
Bag, R., Sikdar, Y., Sahu, S., Maiti, D. K., Frontera, A., Bauzá, A., Drew, M. G. B., & Goswami, S. (2018) · Dalton Transactions · doi:10.1039/c8dt02449a · Cited by 20
Vallejos, J. R., Brorson, K. A., Moreira, A. R., & Rao, G. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22649 · Cited by 21
Luminescence-Based Sensors for Bioprocess Applications
Urriza-Arsuaga, I., Ielasi, G., Bedoya, M., & Orellana, G. (2019) · Springer series on fluorescence · doi:10.1007/4243_2019_10 · Cited by 22
Ihling, N., Munkler, L. P., Berg, C., Reichenbächer, B., Wirth, J., Lang, D., Wagner, R., & Büchs, J. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.725498 · Cited by 20
Construction of mini‐chemostats for high‐throughput strain characterization
Bergenholm, D., Liu, G., Hansson, D., & Nielsen, J. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.26931 · Cited by 22
Multidomain-Based Responsive Materials with Dual-Mode Optical Readouts
You, Y., Biswas, A., Nagaraja, A. T., Hwang, J., Coté, G. L., & McShane, M. J. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b21861 · Cited by 18
Optical non-contact pH measurement in cell culture with sterilizable, modular parts
Rajan, D. K., Patrikoski, M., Verho, J. A., Sivula, J., Ihalainen, H., Miettinen, S., & Lekkala, J. O. (2016) · Talanta · doi:10.1016/j.talanta.2016.09.021 · Cited by 18
Zhou, H., Purdie, J., Wang, T., & Ouyang, A. (2009) · Biotechnology Progress · doi:10.1002/btpr.369 · Cited by 19
Influence of SaOS-2 cells on corrosion behavior of cast Mg-2.0Zn0.98Mn magnesium alloy
Witecka, A., Yamamoto, A., & Święszkowski, W. (2016) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2016.10.041 · Cited by 18
The Technique of Thyroid Cartilage Scaffold Support Formation for Extrusion-Based Bioprinting
Arguchinskaya, N. V., Beketov, E. E., Kisel, A. A., Isaeva, E. V., Osidak, E. O., Domogatsky, S. P., Mikhailovsky, N. V., Sevryukov, F. Е., Silantyeva, N. K., Agababyan, T. A., et al. (2021) · International Journal of Bioprinting · doi:10.18063/ijb.v7i2.348 · Cited by 18
Cotter, J. J., O’Gara, J. P., Stewart, P. S., Pitts, B., & Casey, E. (2010) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2010.04842.x · Cited by 20
Optical Fiber pH and Dissolved Oxygen Sensors for Bioreactor Monitoring: A Review
Cui, G., Wu, R., Cao, L., Abedin, S., Goel, K., Yoon, S., & Wang, X. (2025) · Sensors · doi:10.3390/s26010010 · Cited by 20
“Consequently, DO setpoints and control strategies are now routinely included in QbD studies and risk assessments for biophar-maceutical processes, alongside other critical parameters such as pH, temperature, and nutrient concentrations [79].”
Tang, P., Tan, Z., Ehamparanathan, V., Ren, T., Hoffman, L., Du, C., Song, Y., Tao, L., Lewandowski, A. T., Ghose, S., et al. (2020) · mAbs · doi:10.1080/19420862.2020.1829336 · Cited by 18
Bioreactors and Microfluidics for Osteochondral Interface Maturation
Canadas, R. F., Marques, A. P., Reis, R. L., & Oliveira, J. M. (2018) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-76735-2_18 · Cited by 17
Meier, R. J., Simbürger, J. M. B., Soukka, T., & Schäferling, M. (2015) · Chemical Communications · doi:10.1039/c5cc90142a · Cited by 16
Harrison, R. P., & Chauhan, V. M. (2017) · Biointerphases · doi:10.1116/1.5013335 · Cited by 16
Designing and validation of an automated ex-vivo bioreactor system for long term culture of bone
Dua, R., Jones, H. L., & Noble, P. C. (2021) · Bone Reports · doi:10.1016/j.bonr.2021.101074 · Cited by 13
“Acidification has been shown to be associated with the onset of the apoptosis of the cells in culture (Simpson et al., 1997; Perani et al., 1998; Naciri et al., 2008).”
BackgroundVersatile common instrumentation for optical detection of pH and dissolved oxygen
Sardesai, N., Rao, G., & Kostov, Y. V. (2015) · Review of Scientific Instruments · doi:10.1063/1.4926542 · Cited by 17
Zabadaj, M., Szuplewska, A., Kalinowska, D., Chudy, M., & Ciosek, P. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.05.137 · Cited by 14
Evaluation of bone formation on orthopedic implant surfaces using an ex-vivo bone bioreactor system
Dua, R., Jones, H. L., & Noble, P. C. (2021) · Scientific Reports · doi:10.1038/s41598-021-02070-z · Cited by 17
Valdiani, A., Hansen, O. K., Johannsen, V. K., & Nielsen, U. B. (2019) · International Journal of Environmental Science and Technology · doi:10.1007/s13762-019-02556-4 · Cited by 12
Li, J., Guo, Z., Sato, T., Yuan, B., Ma, Y., Qian, D., Zhong, J.-Y., Jin, M., Huang, P., Che, L., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0196617 · Cited by 11
Silva, A. C., Simão, D. F., Kueppers, C., Lucas, T., Sousa, M. F. Q., Cruz, P. E., Carrondo, M. J. T., Kochanek, S., & Alves, P. M. (2015) · Biotechnology Journal · doi:10.1002/biot.201400765 · Cited by 14
Cost-Effective Real-Time Metabolic Profiling of Cancer Cell Lines for Plate-Based Assays
Blaszczak, W., Tan, Z., & Swietach, P. (2021) · Chemosensors · doi:10.3390/chemosensors9060139 · Cited by 10
High-Throughput Dispensing of Viscous Solutions for Biomedical Applications
Revia, R. A., Wagner, B. M., James, M., & Zhang, M. (2022) · Micromachines · doi:10.3390/mi13101730 · Cited by 8
“Optical sensors used to measure pH and DO have been incorporated into the bottom of well plates in microplate readers to evaluate cell states in 2D, and a good correlation was found between proliferation and both pH and DO [63]; some minor modifications may be needed to apply to 3D models.”
BackgroundArguchinskaya, N. V., Beketov, E. E., Isaeva, E. V., Sergeeva, N. S., Шегай, П. В., Иванов, С. А., & Каприн, А. Д. (2021) · Russian Journal of Transplantology and Artificial Organs · doi:10.15825/1995-1191-2021-1-60-74 · Cited by 8
“Полимеризацию коллагена можно индуцировать и понижением pH раствора [109], однако это может негативно влиять на жизнеспособность клеток в сформированном скаффолде [108, 110].”
Rahmatnejad, V., Tolosa, M., Ge, X., & Rao, G. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.968294 · Cited by 12
A colorimetric sensor for pH utilizing a quinoline derivative
Wang, Q., Li, R., Qiu, S., Lin, Z., Chen, G., & Luo, L. (2014) · Analytical Methods · doi:10.1039/c4ay00899e · Cited by 8
Characterization of GPCR signaling in hypoxia
Chakraborty, R., Sikarwar, A. S., Hinton, M., Dakshinamurti, S., & Chelikani, P. (2017) · Methods in cell biology · doi:10.1016/bs.mcb.2017.07.005 · Cited by 6
Schwamb, S., Puskeiler, R., & Wiedemann, P. (2014) · Cell engineering · doi:10.1007/978-3-319-10320-4_7 · Cited by 9
Wu, M., Sapin‐Minet, A., Stefan, L., Perrin, J., Fries, I., & Gaucher, C. (2024) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2024.125126 · Cited by 6
Trzeciak, T. (2014) · Journal of Cell Science & Therapy · doi:10.4172/2157-7013.1000172 · Cited by 6
“The changing values of these two parameters indicate the beginning of apoptosis [26].”
Evaluating Riboglow-FLIM probes for RNA sensing
Sarfraz, N., Shafik, L. K., Stickelman, Z., Shankar, U., Moscoso, E., & Braselmann, E. (2024) · RSC Chemical Biology · doi:10.1039/d3cb00197k · Cited by 7
Dinter, R., Helwes, L., de Vries, S., Jegatheeswaran, K., Jibben, H., & Kockmann, N. (2024) · Journal of Flow Chemistry · doi:10.1007/s41981-024-00319-y · Cited by 6
Reyes, S., Pham, P. L., Durocher, Y., & Henry, O. (2024) · Biotechnology Progress · doi:10.1002/btpr.3507 · Cited by 8
Sheidaei, Z., Akbarzadeh, P., Nguyen, N., & Kashaninejad, N. (2022) · Biomedical Microdevices · doi:10.1007/s10544-022-00615-1 · Cited by 5
Robinson, K. J., Armstrong, H. C., Moss, S. E. W., Oller, L., Hall, A. J., & Bennett, K. A. (2021) · Methods in Ecology and Evolution · doi:10.1111/2041-210x.13710 · Cited by 5
“They have been used in cell culture (Ge et al., 2006) to measure viability over up to 168 hr (Deshpande et al., 2004; Naciri et al., 2008).”
MethodWang, C.-Y., Liao, H.-F., & Sheu, D. (2010) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2009.08.006 · Cited by 5
Chiu, K., & Du, D. (2024) · Biotechnology and Bioprocess Engineering · doi:10.1007/s12257-024-00141-2 · Cited by 12
“In addition, DO plays a critical role in cell respiration and maintaining cell activities [93].”
Nahid, D. S., Coffey, K. A., Bei, A. K., & Cordy, R. J. (2024) · PLoS Pathogens · doi:10.1371/journal.ppat.1012514 · Cited by 6
Completely noninvasive multi-analyte monitoring system for cell culture processes
Rahmatnejad, V., Tolosa, M., Ge, X.-D., & Rao, G. (2024) · Biotechnology Letters · doi:10.1007/s10529-024-03521-z · Cited by 4
Wong, J. F., Simmons, C. A., & Young, E. W. K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804595-4.00003-1 · Cited by 9
Three Dimensional In Vitro Tumor Platforms for Cancer Discovery
Gadde, M., Marrinan, D., Michna, R. J., & Rylander, M. N. (2017) · Cancer drug discovery and develogment/Cancer drug discovery and development · doi:10.1007/978-3-319-60511-1_5 · Cited by 5
Aiyer, A., Das, T., Whiteley, G. S., Glasbey, T. O., Kriel, F. H., Farrell, J., & Manos, J. (2022) · Biomedicines · doi:10.3390/biomedicines10112886 · Cited by 5
“One could rectify this by conducting optimisation using gas-permeable wells to regulate oxygen bioavailability to cells [25,45].”
BackgroundMicroplate spectrophotometry for high‐throughput screening of cytotoxic molecules
Tomelleri, C., Pellegrina, C. D., & Chignola, R. (2010) · Cell Proliferation · doi:10.1111/j.1365-2184.2009.00665.x · Cited by 5
A 3D‐Printed Microfluidic Sensor Platform for Online Bioprocess Monitoring
Heuer, C., Enders, A., Winkler, S., Klassen, M. D., Teutenberg, T., & Bahnemann, J. (2025) · Advanced Sensor Research · doi:10.1002/adsr.70001 · Cited by 3
Wiegmann, V., Gardner, R. A., Spencer, D. I. R., & Baganz, F. (2021) · Biotechnology Journal · doi:10.1002/biot.202100360 · Cited by 6
“Cultures in the 24 SRW were not pH controlled and were therefore subjected to a changing pH environment as illustrated by previous studies that employed pH monitoring in microwell cultivations of CHO cells.[33,34] An effect of the culture pH on the glycoprofile has been reported frequently in the literature but proved…”
MethodSedighikamal, H., Sattarzadeh, A., Mostofi, R. K., Dinarvand, B., & Nazarpour, M. (2023) · ACS Omega · doi:10.1021/acsomega.3c03007 · Cited by 4
Vos, W. H. D., Meesen, G., Szpirer, C., Scohy, S., Cherukuri, C., Evrard, O., Hutsebaut, X., & Beghuin, D. (2012) · Planetary and Space Science · doi:10.1016/j.pss.2012.07.015 · Cited by 4
“This is why there should be a continuous verification of cell culture condition, not only by monitoring physico-chemical parameters like oxygen consumption and medium pH (Harms et al., 2002; Hanson et al., 2007; Naciri et al., 2008) but also by gauging cellular parameters such as cell density and cell morphology.”
BackgroundMiniaturized Integrated Platform for Electrical and Optical Monitoring of Cell Cultures
Moldovan, C. A., Iosub, R., Codreanu, C., Fîrtat, B., Necula, D., Brașoveanu, C., & Stan, I. (2012) · Sensors · doi:10.3390/s120811372 · Cited by 3
“pH variations during the cells’ growth, maturity and death phases depends on the particular type of cell culture, media, air composition and temperature conditions [15,16].”
BackgroundReal-time characterization of mammalian cell culture bioprocesses by magnetic sector MS
Floris, P., Dorival–García, N., Lewis, G., Josland, G. D., Merriman, D., & Bones, J. (2020) · Analytical Methods · doi:10.1039/d0ay01563f · Cited by 5
A Novel Paper Based Point of Care Blood pH Sensor
Awasthi, P., & Das, S. (2018) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2018.8589927 · Cited by 2
“[1-3].”
Monitoring oxygen uptake in 3D tissue engineering scaffolds by phosphorescence quenching microscopy
Guaccio, A., & Netti, P. A. (2010) · Biotechnology Progress · doi:10.1002/btpr.438 · Cited by 2
PMF as a driver of persister sensitization by adenosinePreprint
Thompson, N. T., Kitzenberg, D., Dowdell, A. S., Roer, R. L., Lee, J. S., Worledge, C. S., Colgan, S. P., & Kao, D. J. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.05.28.655832 · Cited by 2
“Oxygen saturation was measured with a PreSens OxoDish at 37°C with agitation (14).”
Rajan, D. K. (2020) · Engineering Archive (engrXiv) · doi:10.31224/osf.io/3e7cd · Cited by 1
Arossa, S., Alsolami, S. M., Klein, S. G., Zhang, Y., Ramos‐Mandujano, G., Steckbauer, A., Parry, A. J., Izpisúa‐Belmonte, J. C., Duarte, C. M., & Li, M. (2022) · Life Medicine · doi:10.1093/lifemedi/lnac056 · Cited by 1
Ragupathy, V., Setty, M. K. H. G., Kostov, Y. V., Ge, X., Uplekar, S. D., HEWLETT, I. K., & Rao, G. (2015) · Sensors · doi:10.3390/s150714864 · Cited by 1
“A study published in 2008 [9] by directly measuring dissolved oxygen and pH provides a reliable approach to long-term online monitoring.”
BackgroundLee, N. D., Kondragunta, B., Uplekar, S. D., Vallejos, J. R., Moreira, A., & Rao, G. (2015) · PDA journal of pharmaceutical science and technology · doi:10.5731/pdajpst.2015.01035
Universal optical platform for monitoring of bioprocess variables
Sardesai, N., Rao, G., & Kostov, Y. V. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2179721 · Cited by 3
Metadata
- Authors
- Naciri, M., Kuystermans, D., & Al-Rubeai, M.
- Affiliations
- University College Dublin (IE)
- Corresponding author
- Naciri, Mariam
- ORCID
- Naciri, Mariam
- Venue
- Cytotechnology
- Published
- 2008-07
- Volume
- 57
- Issue
- 3
- Pages
- 245-250
- ISSN
- 0920-9069 (ISSN-L)
- 1573-0778
- PMC
- PMC2570003
- OpenAlex
- W2070187046
- Cited by
- 111
- References
- 17
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 7 · 2023: 2 · 2022: 10 · 2021: 10 · 2020: 8 · 2019: 7 · 2018: 9 · 2017: 9 · 2016: 7 · 2015: 11 · 2014: 6 · 2013: 3 · 2012: 4
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Cytotechnology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Science Foundation Ireland
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Viral Infectious Diseases and Gene Expression in Insects
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Keywords
- mammalian cell culture, dissolved oxygen, pH monitoring, fluorescent sensors, optical sensors, NS0 cells, CHO cells, batch culture, serum concentration, process control, online monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.