Neuroprostheses based on electrical stimulation are becoming a therapeutic reality, dramatically improving the life of disabled people. They are based on neural interfaces that are designed to create an intimate contact with neural cells. These devices speak the language of electron currents, while the human nervous system uses ionic currents to communicate. A deep understanding of the complex interplay between these currents, during the electrical stimulation, is essential for the development of optimized neuroprostheses. Neural electrodes can have different geometries, placement within the nervous system, and the stimulation protocols (paradigms of use). This high-dimensional problem is not tractable by an empiric, brute-force approach and should be tackled by exact computational models, making use of our accumulated knowledge. In pursuit of this goal, a hybrid finite element method-NEURON modeling-is used for a solution of electrical field generated by stimulation, within the different neural structures having anisotropic conductivity, and a corresponding neural response computation. In this work, an important correction of perineurium electrical conductivity is computed. Models of median and sciatic nerves, innervating the hand and foot areas, relevant to the development of bionic hands and legs with sensory feedback, are implemented. The obtained results have the potential to optimize the design of neural interfaces, in terms of shape and number of stimulating contacts. Guidelines for the neurosurgical planning are proposed, by indicating the optimal number of implants for a specific nerve to obtain the best efficacy with the lowest invasiveness. The interpretation is proposed for one of the basic problems of neural interfaces, consisting in the change of the stimulation threshold due to fibrotic reaction of tissue. We show that it is possible to use human microstimulation as an experimental setup for testing of afferent stimulation paradigms, which can be translated to further chronic implants. In the future, models will have a key role in the decision of the most appropriate design of customized neuroprostheses, their optimal modality of use, understanding the effects that occur during their use, and minimizing animal and human experimentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 2×
“This is due to the fact that neuroprostheses can stimulate by a range of different values for frequency, pulse width and amplitude, delivered through multiple active sites (ASs), located in various positions within the nervous system [11].”
BackgroundMethodRestoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 10×
“This situation corresponds to the one observed in [6] for the ulnar AS used for the prosthesis control.”
BackgroundMethodResultSelf-citationVisual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 2×
“At first, research efforts were oriented to understand the biocompatibility and basic functionality [8], [9] of the proposed devices, however, the need for an exhaustive understanding of the interaction between implanted electrodes and the response of the neural tissue became evident [10].”
BackgroundA neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · cited 15×
“, evocation of more natural sensations in amputees [7] and the combinations of several ASs [40]) should be extensively explored.”
BackgroundMethodResultInfluentialAngeli, C. A., Edgerton, V. R., Gerasimenko, Y. P., & Harkema, S. J. (2014) · Brain · doi:10.1093/brain/awu038 · Cited by 750 · cited 1×
“They have shown their beneficial effects in the treatment of Parkinson disease, by means of deep brain stimulation (DBS) [1], certain type of blindness by retinal implants [2], deafness by cochlear stimulation [3], walking rehabilitation in spinal cord injured (SCI) patients by epidural stimulation [4], pain suppressi…”
BackgroundAnalysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 5×
“A good tradeoff between the two previous solutions can be found in intraneural interfaces, such as the transverse intrafascicular multichannel electrode (TIME) [32], or SELINE electrodes [33], both consisting of a polyimide substrate with ASs on both sides.”
BackgroundInfluentialA Computational Model for Epidural Electrical Stimulation of Spinal Sensorimotor Circuits
Capogrosso, M., Wenger, N., Raspopovic, S., Musienko, P., Beauparlant, J., Bassi Luciani, L., Courtine, G., & Micera, S. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1688-13.2013 · Cited by 435 · cited 3×
“Indeed, computer simulations [23]–[25] provided evidence that EES primarily engages large myelinated fibers associated with proprioceptive and cutaneous feedback circuits during the SCI rehabilitation.”
BackgroundMethod
Cited by
Valle, G., Mazzoni, A., Iberite, F., D’Anna, E., Strauss, I., Granata, G., Controzzi, M., Clemente, F., Rognini, G., Cipriani, C., et al. (2018) · Neuron · doi:10.1016/j.neuron.2018.08.033 · Cited by 345
Self-citationSensory feedback restoration in leg amputees improves walking speed, metabolic cost and phantom pain
Petrini, F. M., Bumbasirevic, M., Valle, G., Ilic, V., Mijović, P., Čvančara, P., Barberi, F., Katic, N., Bortolotti, D., Andreu, D., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0567-3 · Cited by 269
Self-citationEnhancing functional abilities and cognitive integration of the lower limb prosthesis
Petrini, F. M., Valle, G., Bumbasirevic, M., Barberi, F., Bortolotti, D., Cvancara, P., Hiairrassary, A., Mijovic, P., Sverrisson, A. Ö., Pedrocchi, A., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav8939 · Cited by 265
Self-citationSix‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback
Petrini, F. M., Valle, G., Strauss, I., Granata, G., Di Iorio, R., D'Anna, E., Čvančara, P., Mueller, M., Carpaneto, J., Clemente, F., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25384 · Cited by 195
Self-citationVallone, F., Ottaviani, M. M., Dedola, F., Cutrone, A., Romeni, S., Panarese, A. M., Bernini, F., Cracchiolo, M., Strauss, I., Gabisonia, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0d42 · Cited by 35
Metadata
- Authors
- Raspopovic, S., Petrini, F. M., Zelechowski, M., & Valle, G.
- Venue
- Proceedings of the IEEE
- Published
- 2017-01
- Volume
- 105
- Issue
- 1
- Pages
- 34-49
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2519728469
- Cited by
- 84
- References
- 25
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Framework for the Development of Neuroprostheses: From Basic Understanding by Sciatic and Median Nerves Models to Bionic Legs and Hands. https://app.cochat.ai/papers/10.1109/jproc.2016.2600560
- The paper
- Raspopovic, S., Petrini, F. M., Zelechowski, M., & Valle, G. (2017). Framework for the Development of Neuroprostheses: From Basic Understanding by Sciatic and Median Nerves Models to Bionic Legs and Hands. Proceedings of the IEEE. https://doi.org/10.1109/jproc.2016.2600560
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.