Probabilistic modeling of selective stimulation of the human sciatic nerve with a flat interface nerve electrode
Open accessThe DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
Ankle control is critical to both standing balance and efficient walking. The hypothesis presented in this paper is that a Flat Interface Nerve Electrode (FINE) placed around the sciatic nerve with a fixed number of contacts at predetermined locations and without a priori knowledge of the nerve's underlying neuroanatomy can selectively control each ankle motion. Models of the human sciatic nerve surrounded by a FINE of varying size were created and used to calculate the probability of selective activation of axons within any arbitrarily designated, contiguous group of fascicles. Simulations support the hypothesis and suggest that currently available implantable technology cannot selectively recruit each target plantar flexor individually but can restore plantar flexion or dorsiflexion from a site on the sciatic nerve without spillover to antagonists. Successful activation of individual ankle muscles in 90% of the population can be achieved by utilizing bipolar stimulation and/or by using a cuff with at least 20 contacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Nerve electrodes activate populations of axons on the basis of size and location relative to the stimulating contact (23).”
From A neural interface provides long-term stable natural touch perception (2014) · cites this paper as [23]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Biomechanics and Motor Control of Human Movement
Winter, D. A. (2009) · Wiley eBooks · doi:10.1002/9780470549148 · Cited by 6,066
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933
Electroencephalography and clinical neurophysiology
(1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90118-x · Cited by 1,759
The Journal of Rehabilitation Research and Development
(2025) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.0000.00.0000 · Cited by 1,566
(2013) · Experimental Brain Research · doi:10.1007/221.1432-1106 · Cited by 1,096
McIntyre, C. C., Richardson, A. G., & Grill, W. M. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00353.2001 · Cited by 761
Are Current Measurements of Lower Extremity Muscle Architecture Accurate?
Ward, S. R., Eng, C. M., Smallwood, L. H., & Lieber, R. L. (2009) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-008-0594-8 · Cited by 693
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 1×
“Similar results have been found with intrafascicular electrodes (Badia et al. 2011; Boretius et al. 2010; Nannini and Horch 1991; Yoshida and Horch 1993).”
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 1×
“Other animal experiments have shown that the FINE can selectively restore individual functions controlled by the SN (Leventhal and Durand 2003; Tarler and Mortimer 2003; Tyler and Durand 2002).”
Self-citationMotor unit physiology: Some unresolved issues
Enoka, R. M., & Fuglevand, A. J. (2001) · Muscle & Nerve · doi:10.1002/1097-4598(200101)24:1<4::aid-mus13>3.0.co;2-f · Cited by 390
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 1×
“…spiral nerve cuff electrodes placed around (Grill and Mortimer 1996; Sweeney et al. 1990; Tarler and Mortimer 2003, 2004, 2007; Veraart et al. 1993) or a penetrating electrode array placed in the SN (Branner and Normann 2000; Branner et al. 2004; Branner et al. 2001; McDonnall et al. 2004a, b).”
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320 · cited 1×
“…been reported with spiral nerve cuff electrodes placed around (Grill and Mortimer 1996; Sweeney et al. 1990; Tarler and Mortimer 2003, 2004, 2007; Veraart et al. 1993) or a penetrating electrode array placed in the SN (Branner and Normann 2000; Branner et al. 2004; Branner et al. 2001; McDonnall…”
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · cited 1×
“…spiral nerve cuff electrodes placed around (Grill and Mortimer 1996; Sweeney et al. 1990; Tarler and Mortimer 2003, 2004, 2007; Veraart et al. 1993) or a penetrating electrode array placed in the SN (Branner and Normann 2000; Branner et al. 2004; Branner et al. 2001; McDonnall et al. 2004a, b).”
Recent demographic and injury trends in people served by the model spinal cord injury care systems
Nobunaga, A. I., Go, B. K., & Karunas, R. B. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90247-2 · Cited by 280
Clinical use of the odstock dropped foot stimulator: Its effect on the speed and effort of walking
Taylor, P. N., Burridge, J. H., Dunkerley, A. L., Wood, D. E., Norton, J. A., Singleton, C., & Swain, I. D. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90333-7 · Cited by 275 · cited 1×
“Surface electrodes can restore dorsiflexion by activating the tibialis anterior, but frequently recruit the peroneus longus , which everts and plantar flexes the foot (O'Keeffe and Lyons 2002; Taylor et al. 1999).”
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234 · cited 1×
“…spiral nerve cuff electrodes placed around (Grill and Mortimer 1996; Sweeney et al. 1990; Tarler and Mortimer 2003, 2004, 2007; Veraart et al. 1993) or a penetrating electrode array placed in the SN (Branner and Normann 2000; Branner et al. 2004; Branner et al. 2001; McDonnall et al. 2004a, b).”
Prevalence of Stroke—United States, 2006–2010
(2012) · JAMA · doi:10.1001/jama.308.3.228 · Cited by 232
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227
Feiereisen, P., Duchateau, J., & Hainaut, K. (1997) · Experimental Brain Research · doi:10.1007/pl00005610 · Cited by 217
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208 · cited 1×
“Similar results have been found with intrafascicular electrodes (Badia et al. 2011; Boretius et al. 2010; Nannini and Horch 1991; Yoshida and Horch 1993).”
A nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196 · cited 1×
“In cat studies, selective and graded muscle contractions have been reported with spiral nerve cuff electrodes placed around (Grill and Mortimer 1996; Sweeney et al. 1990; Tarler and Mortimer 2003, 2004, 2007; Veraart et al. 1993) or a penetrating electrode array placed in the SN (Branner and…”
The specific impedance of the dorsal columns of cat: An anisotropic medium
Ranck Jr., J. B., & BeMent, S. L. (1965) · Experimental Neurology · doi:10.1016/0014-4886(65)90059-2 · Cited by 185
Modelling the effects of electric fields on nerve fibres: Influence of the myelin sheath
Richardson, A. G., McIntyre, C. C., & Grill, W. M. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345014 · Cited by 179
Kobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155 · cited 1×
“Intramuscular electrodes can also produce reciprocal, but energetically inefficient stepping in individuals paralyzed by spinal cord injury (Kobetic et al. 1999; Sharma et al. 1998).”
Self-citationSchiefer, M. A., Triolo, R. J., & Tyler, D. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918425 · Cited by 148 · cited 8×
“Simulated platinum stimulating surfaces were 0.5×0.5 mm and spaced 1.0 mm on-center (Schiefer et al. 2008; Tyler and Durand 2003).”
InfluentialSelf-citationFascicular perineurium thickness, size, and position affect model predictions of neural excitation
Grinberg, Y., Schiefer, M. A., Tyler, D. J., & Gustafson, K. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010348 · Cited by 145 · cited 4×
“Models have shown that decreased perineurial conductance increases axonal thresholds, but that population recruitment trends remain unaffected (Grinberg et al. 2008).”
InfluentialSelf-citationChronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144 · cited 2×
“Simulated platinum stimulating surfaces were 0.5×0.5 mm and spaced 1.0 mm on-center (Schiefer et al. 2008; Tyler and Durand 2003).”
InfluentialSelf-citationMacefield, V. G., Fuglevand, A. J., & Bigland-Ritchie, B. (1996) · Journal of Neurophysiology · doi:10.1152/jn.1996.75.6.2509 · Cited by 143
Fatone, S., Gard, S. A., & Malas, B. S. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.11.012 · Cited by 140
Neural signals for command control and feedback in functional neuromuscular stimulation: a review.
Hoffer, J. A., Rb, S., Haugland, M. K., Sinkjær, T., Durfee, W. K., Schwartz, A., Loeb, G. E., & Kantor, C. (1996) · PubMed · Cited by 139
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136 · cited 1×
“In cat studies, selective and graded muscle contractions have been reported with spiral nerve cuff electrodes placed around (Grill and Mortimer 1996; Sweeney et al. 1990; Tarler and Mortimer 2003, 2004, 2007; Veraart et al. 1993) or a penetrating electrode array placed in the SN (Branner and…”
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130 · cited 3×
“This design was found to be optimal in computer simulations of the femoral nerve (Schiefer et al. 2008) and shown to be effective during intraoperative cuff evaluations (Schiefer et al. 2010).”
Self-citationSelectivity of multiple-contact nerve cuff electrodes: a simulation analysis
Choi, A. Q., Cavanaugh, J. K., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909637 · Cited by 121 · cited 5×
“The conductivity of the perineurium , epineurium, and saline were isotropic and set at 2, 83, and 2000 mS/m, respectively, whereas the conductivity of the endoneurium was set at 83 mS/m in the transverse directions and 571 mS/m along the extruded direction (Choi et al. 2001).”
InfluentialTarler, M. D., & Mortimer, J. T. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828415 · Cited by 110
Gustafson, K. J., Pinault, G. C. J., Neville, J. J., Syed, I., Jr, J. A. D., Jean-Claude, J., & Triolo, R. J. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.08.0097 · Cited by 107
Self-citationMicroanatomical structure of the human sciatic nerve
Ugrenović, S., Ivan, J., & Stefanović, B. D. (2008) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-008-0386-6 · Cited by 106
Topographical distribution of motor fascicles in the sciatic‐tibial nerve of the rat
Badia, J., Pascual‐Font, A., Vivó, M., Udina, E., & Navarro, X. (2010) · Muscle & Nerve · doi:10.1002/mus.21652 · Cited by 98 · cited 1×
“For example, the rat SN contains less than 5 fascicles and the cat SN contains 5 to 10 fascicles whereas the human SN contains 25 to 70, depending on the location along the nerve (Badia et al. 2010; Gustafson et al. 2011; Sladjana et al. 2008).”
McDonnall, D., Clark, G. A., & Normann, R. A. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828425 · Cited by 98 · cited 1×
“…spiral nerve cuff electrodes placed around (Grill and Mortimer 1996; Sweeney et al. 1990; Tarler and Mortimer 2003, 2004, 2007; Veraart et al. 1993) or a penetrating electrode array placed in the SN (Branner and Normann 2000; Branner et al. 2004; Branner et al. 2001; McDonnall et al. 2004a, b).”
A modeling study of nerve fascicle stimulation
Veltink, P. H., van Veen, B. K., Struijk, J. J., Holsheimer, J., & Boom, H. B. K. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32100 · Cited by 95 · cited 2×
“The conductance value used falls within the rage reported in literature: 0.6–10 mS/m (Choi et al. 2001; Deurloo et al. 2001, 2003; Koole et al. 1997; Perez-Orive and Durand 2000; Veltink et al. 1989).”
InfluentialMuscle recruitment with intrafascicular electrodes
Nannini, N., & Horch, K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83589 · Cited by 94
Kernell, D., Eerbeek, O., & Verhey, B. A. (1983) · Experimental Brain Research · doi:10.1007/bf00239185 · Cited by 87
Subfascicle stimulation selectivity with the flat interface nerve electrode
Leventhal, D. K., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569266 · Cited by 81 · cited 2×
“Other animal experiments have shown that the FINE can selectively restore individual functions controlled by the SN (Leventhal and Durand 2003; Tarler and Mortimer 2003; Tyler and Durand 2002).”
Coupling of antagonistic ankle muscles during co-contraction in humans
Hansen, S., Hansen, N. L., Christensen, L. O. D., Petersen, N., & Nielsen, J. B. (2002) · Experimental Brain Research · doi:10.1007/s00221-002-1152-3 · Cited by 80
AC impedance of the perineurium of the frog sciatic nerve
Weerasuriya, A., Spangler, R. A., Рапопорт, С. И., & Taylor, R. E. (1984) · Biophysical Journal · doi:10.1016/s0006-3495(84)84009-6 · Cited by 80
Localization and Recovery of Peripheral Neural Sources With Beamforming Algorithms
Wodlinger, B., & Durand, D. M. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2034072 · Cited by 73 · cited 1×
“Similar techniques have been used in other studies (Butson et al. 2011; Deurloo et al. 1998; Grinberg et al. 2008; Lertmanorat et al. 2006; Leventhal and Durand 2003; Schiefer et al. 2008; Veltink et al. 1989; Wodlinger and Durand 2009).”
Predicting myelinated axon activation using spatial characteristics of the extracellular field
Peterson, E. J., Izad, O., & Tyler, D. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046030 · Cited by 64
Self-citationStructure and function of the ankle dorsiflexor muscles in young and moderately active men and women
Holmbäck, A. M., Porter, M. M., Downham, D. Y., Andersen, J. L., & Lexell, J. E. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00517.2002 · Cited by 63
Gustafson, K. J., Grinberg, Y., Joseph, S., & Triolo, R. J. (2012) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.10.0201 · Cited by 59
Self-citationSelective Stimulation of the Canine Hypoglossal Nerve Using a Multi-contact Cuff Electrode
Yoo, P. B., Şahin, M., & Durand, D. M. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000019170.74375.fb · Cited by 57
The Nerve Fibre Populations of the Nerves of the Leg in Chronic Occlusive Arterial Disease in Man
Garven, H. S. D., Gairns, F. W., & Smith, G. (1962) · Scottish Medical Journal · doi:10.1177/003693306200700602 · Cited by 57
Recruitment characteristics of nerve fascicles stimulated by a multigroove electrode
Koole, P., Holsheimer, J., Struijk, J. J., & Verloop, A. J. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559348 · Cited by 56 · cited 1×
“The conductance value used falls within the rage reported in literature: 0.6–10 mS/m (Choi et al. 2001; Deurloo et al. 2001, 2003; Koole et al. 1997; Perez-Orive and Durand 2000; Veltink et al. 1989).”
InfluentialModeling study of peripheral nerve recording selectivity
Perez-Perive, J., & Durund, D. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867874 · Cited by 55
Selective motor unit recruitment via intrafascicular multielectrode stimulation
McDonnall, D., Clark, G. A., & Normann, R. A. (2004) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y04-047 · Cited by 53 · cited 1×
“…spiral nerve cuff electrodes placed around (Grill and Mortimer 1996; Sweeney et al. 1990; Tarler and Mortimer 2003, 2004, 2007; Veraart et al. 1993) or a penetrating electrode array placed in the SN (Branner and Normann 2000; Branner et al. 2004; Branner et al. 2001; McDonnall et al. 2004a, b).”
Human Lower Limb Muscles: an Evaluation of Weight and Fiber Size
Ito, J., Moriyama, H., INOKUCHI, S., & Noboru, G. O. T. O. (2003) · Okajimas Folia Anatomica Japonica · doi:10.2535/ofaj.80.47 · Cited by 53
Powers, R. K., & Binder, M. D. (1991) · Journal of Neurophysiology · doi:10.1152/jn.1991.66.6.1838 · Cited by 49
Transverse tripolar stimulation of peripheral nerve: a modelling study of spatial selectivity
Deurloo, K. E. I., Holsheimer, J., & Boom, H. B. K. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522860 · Cited by 46
Lertmanorat, Z., Gustafson, K. J., & Durand, D. M. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9012-5 · Cited by 44
Ohira, Y., Yoshinaga, T., Nonaka, I., Ohara, M., Yoshioka, T., Yamashita-Goto, K., Izumi, R., Yasukawa, K., Sekiguchi, C., Shenkman, B. S., et al. (2000) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.50.41 · Cited by 43
Selective neural activation in a histologically derived model of peripheral nerve
Butson, C. R., Miller, I. O., Normann, R. A., & Clark, G. A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036009 · Cited by 42
Deurloo, K. E. I., Holsheimer, J., & Bergveld, P. (2001) · Biological Cybernetics · doi:10.1007/s004220100253 · Cited by 40
Implantation of a 16-Channel Functional Electrical Stimulation Walking System
Sharma, M., Marsolais, E. B., Polando, G., Triolo, R. J., Davis, J. A., Bhadra, N., & Uhlir, J. P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199802000-00029 · Cited by 37
Self-citationForce development and relaxation in single motor units of adult cats during a standard fatigue test.
Gordon, D. A., Enoka, R. M., Karst, G. M., & Stuart, D. G. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp017963 · Cited by 37
Comparison of joint torque evoked with monopolar and tripolar-cuff electrodes
Tarler, M. D., & Mortimer, J. T. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.816867 · Cited by 35
Intraoperative evaluation of the spiral nerve cuff electrode on the femoral nerve trunk
Polasek, K. H., Schiefer, M. A., Pinault, G. C. J., Triolo, R. J., & Tyler, D. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066005 · Cited by 33 · cited 1×
“This included splitting the cuff, the contact seen in the upper right corner of the cuff, all neural tissue, and the saline environment (not shown) of activated axons not innervating the target to no more than 10% (Choi et al. 2001; K. H. Polasek et al. 2009 ).”
Self-citationMechanical and electromyographic analysis of reciprocal inhibition at the human ankle joint
Sinkjær, T., Nielsen, J. B., & Toft, E. S. (1995) · Journal of Neurophysiology · doi:10.1152/jn.1995.74.2.849 · Cited by 27
Woock, J. P., Yoo, P. B., & Grill, W. M. (2010) · BMC Urology · doi:10.1186/1471-2490-10-11 · Cited by 21
Deurloo, K. E. I., Holsheimer, J., & Bergveld, P. (2003) · Neuromodulation: Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03034.x · Cited by 20 · cited 2×
“The conductance value used falls within the rage reported in literature: 0.6–10 mS/m (Choi et al. 2001; Deurloo et al. 2001, 2003; Koole et al. 1997; Perez-Orive and Durand 2000; Veltink et al. 1989).”
InfluentialA versatile drop foot stimulator for research applications
O'Keeffe, D. T., & Lyons, G. M. (2002) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00011-5 · Cited by 19
Linear Summation of Torque Produced by Selective Activation of Two Motor Fascicles
Tarler, M. D., & Mortimer, J. T. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891377 · Cited by 14
Maximum tension predicts relative endurance of fast-twitch motor units in the cat
Botterman, B. R., & Cope, T. C. (1988) · Journal of Neurophysiology · doi:10.1152/jn.1988.60.4.1215 · Cited by 12
Comparison of the histochemical and contractile properties of human triceps surae
Moss, C. L. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446791 · Cited by 8
The behaviour of isolated mammalian muscle spindles with intact innervation.
Boyd, I. A. (1968) · PubMed · Cited by 6
Td, R. (1968) · PubMed · Cited by 5
Comparison of the histochemical and contractile properties of human triceps surae
Rolfe, P. J., Rice, C. L., Cunningham, D. A., Taylor, A. W., Paterson, D. H., & Moss, C. L. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02524708 · Cited by 4
Research works printed but not linked: 4
- Acosta AM 2002 Dissertation on Musculoskeletal modeling of the shoulder and elbow in cervical spinal cord injury Case Western Reserve University Cleveland
- Boyd IA 1968 The structure and innervation of mammalian muscle spindles Electroencephalogr Clin Neurophysiol 25 4 406 4176596
- CDC 2007 Morbidity and Mortality Weekly Report 56 19 469 474 17510610
- Polasek K 2007 Clincial implementation of nerve cuff electrodes for an upper extremity neuroprosthesis Dissertation Case Western Reserve University Cleveland
Cited by
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Self-citationTan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026002 · Cited by 175
Self-citationA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Neural interfaces for somatosensory feedback: bringing life to a prosthesis
Tyler, D. J. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000266 · Cited by 105
Self-citationRaspopovic, S., Petrini, F. M., Zelechowski, M., & Valle, G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2600560 · Cited by 84
Metadata
- Authors
- Schiefer, M. A., Tyler, D. J., & Triolo, R. J.
- Affiliations
- Case Western Reserve University (US)
- Louis Stokes Cleveland VA Medical Center (US)
- Corresponding author
- Schiefer, Matthew A.
- Venue
- Journal of Computational Neuroscience
- Published
- 2012-01-06
- Volume
- 33
- Issue
- 1
- Pages
- 179-190
- ISSN
- 0929-5313 (ISSN-L)
- 1573-6873
- PMC
- PMC3357453
- OpenAlex
- W2008965098
- Cited by
- 53
- References
- 76
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 4 · 2023: 5 · 2022: 3 · 2021: 3 · 2020: 4 · 2019: 4 · 2018: 5 · 2017: 4 · 2016: 2 · 2015: 5 · 2014: 2 · 2013: 4
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Computational Neuroscience (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Veterans Affairs (I01-RX001039)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (T32AR007505)
- National Institute of Biomedical Imaging and Bioengineering (R01EB001889)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- sciatic nerve, selective nerve stimulation, ankle control, plantar flexion, dorsiflexion, nerve fascicles, bipolar stimulation, cuff electrodes, ankle prosthesis, neuromodulation, standing balance
- MeSH terms
- Ankle Joint, Axons, Biophysics, Electric Stimulation, Electrodes, Electrodes, Implanted, Humans, Models, Theoretical, Movement, Probability, Recruitment, Neurophysiological, Sciatic Nerve
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.