In vitro degradation and cell attachment of a PLGA coated biodegradable Mg–6Zn based alloy
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
In vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,395
Mechanisms of polymer degradation and erosion
Göpferich, A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85755-3 · Cited by 1,781
The development of binary Mg–Ca alloys for use as biodegradable materials within bone
Li, Z., Gu, X., Lou, S., & Zheng, Y. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.021 · Cited by 1,593
Control of biodegradation of biocompatable magnesium alloys
Song, G. (2007) · Corrosion Science · doi:10.1016/j.corsci.2007.01.001 · Cited by 1,514
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
In vitro and in vivo corrosion measurements of magnesium alloys
Witte, F., Fischer, J., Nellesen, J., Crostack, H.-A., Kaese, V., Pisch, A., Beckmann, F., & Windhagen, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.037 · Cited by 1,386
Saris, N.-E. L., Mervaala, E., Karppanen, H., Khawaja, J. A., & Lewenstam, A. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(99)00258-2 · Cited by 1,366
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Research on an Mg–Zn alloy as a degradable biomaterial
Zhang, S., Zhang, X., Zhao, C., Li, J., Song, Y., Xie, C., Tao, H., Zhang, Y., He, Y., Jiang, Y., et al. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.06.028 · Cited by 1,336
Self-citation
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Biomedical coatings on magnesium alloys – A review
Hornberger, H., Virtanen, S., & Boccaccini, A. R. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.012 · Cited by 1,273
Agarwal, S., Curtin, J., Duffy, B., & Jaiswal, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.06.020 · Cited by 955
Zhao, D., Witte, F., Lu, F., Wang, J., Li, J., & Qin, L. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2016.10.017 · Cited by 945
Self-citationNovel Magnesium Alloys Developed for Biomedical Application: A Review
Li, N., & Zheng, Y. (2013) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2013.02.005 · Cited by 744
Bone biomaterials and interactions with stem cells
Gao, C., Peng, S., Feng, P., & Shuai, C. (2017) · Bone Research · doi:10.1038/boneres.2017.59 · Cited by 720
Advances in functionalized polymer coatings on biodegradable magnesium alloys–A review
Li, L.-Y., Cui, L.-Y., Zeng, R.-C., Li, S.-Q., Chen, X.-B., Zheng, Y., & Kannan, M. B. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.030 · Cited by 466
Li, X., Liu, X., Wu, S., Yeung, K. W. K., Zheng, Y., & Chu, P. K. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.09.005 · Cited by 428
Zhou, H., Liang, B., Jiang, H., Deng, Z., & Yu, K. (2021) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.03.004 · Cited by 377
Methods and materials for additive manufacturing: A critical review on advancements and challenges
Bhuvanesh Kumar, M., & Sathiya, P. (2021) · Thin-Walled Structures · doi:10.1016/j.tws.2020.107228 · Cited by 372
Surface design of biodegradable magnesium alloys — A review
Wu, G., Ibrahim, J. M., & Chu, P. K. (2013) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2012.10.009 · Cited by 358
Biodegradable metallic bone implants
Shuai, C., Li, S., Peng, S., Feng, P., Lai, Y., & Gao, C. (2019) · Materials Chemistry Frontiers · doi:10.1039/c8qm00507a · Cited by 275
Wang, J., Tang, J., Zhang, P., Li, Y., Wang, J., Lai, Y., & Qin, L. (2012) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.32707 · Cited by 234
Challenges and opportunities for biodegradable magnesium alloy implants
Kumar, K., Gill, R. S., & Batra, U. (2018) · Materials Technology · doi:10.1080/10667857.2017.1377973 · Cited by 182
Magnesium based degradable biomaterials: A review
Gu, X.-N., Li, S.-S., Li, X.-M., & Fan, Y.-B. (2014) · Frontiers of Materials Science · doi:10.1007/s11706-014-0253-9 · Cited by 176
“[117] have prepared a PLGA coating on Mg–6Zn alloy with the coating thickness of 33 and 72 μm determined by PLGA concentration.”
Method
Metadata
- Authors
- Li, J. N., Cao, P., Zhang, X. N., Zhang, S. X., & He, Y. H.
- Venue
- Journal of Materials Science
- Published
- 2010-06-15
- Volume
- 45
- Issue
- 22
- Pages
- 6038-6045
- ISSN
- 0022-2461 (ISSN-L)
- 1573-4803
- OpenAlex
- W2008446068
- Cited by
- 177
- References
- 25
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.