Abstract

A cross-linking reagent is required to improve mechanical strength and degradation properties of biopolymers for tissue engineering. To find the optimal preparative method, we prepared diverse genipin-cross-linked chitosan/collagen scaffolds using different genipin concentrations and various cross-linking temperatures and cross-linking times. The compressive strength increased with the increasing of genipin concentration from 0.1 to 1.0%, but when concentration exceeded 1.0%, the compressive strength decreased. Similarly, the compressive strength increased with the increasing of temperature from 4 to 20°C, but when temperature reached 37°C, the compressive strength decreased. Showing a different trend from the above two factors, the effect of cross-linking time on the compressive strength had a single increasing tendency. The other results also demonstrated that the pore size, degradation rate and swelling ratio changed significantly with different cross-linking conditions. Based on our study, 1.0% genipin concentration, 20°C cross-linking temperature and longer cross-linking time are recommended.

Integrity signals

Registry

Crossref · 10.1007/s10856-010-4177-3

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Bi, L., Cao, Z., Hu, Y., Song, Y., Yu, L., Yang, B., Mu, J., Huang, Z., & Han, Y.
Affiliations
  • Xijing Hospital (CN)
  • First Affiliated Hospital of Chinese PLA General Hospital (CN)
Corresponding author
Han, Yisheng
Venue
Journal of Materials Science: Materials in Medicine
Published
2010-11-05
Volume
22
Issue
1
Pages
51-62
ISSN
  • 0957-4530 (ISSN-L)
  • 1573-4838
OpenAlex
W2073027474
Cited by
215
References
44
Citations by year
2026: 6 · 2025: 15 · 2024: 10 · 2023: 16 · 2022: 18 · 2021: 16 · 2020: 26 · 2019: 22 · 2018: 17 · 2017: 10 · 2016: 10 · 2015: 13 · 2014: 9 · 2013: 9 · 2012: 14
FWCI
3.56
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Materials Science Materials in Medicine (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Science Foundation
Topics
  • Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
Keywords
genipin, chitosan, collagen, cartilage tissue engineering, compressive strength, crosslinking temperature, crosslinking time, pore size, degradation rate, swelling ratio
MeSH terms
Animals, Biocompatible Materials, Biomechanical Phenomena, Cartilage, Cells, Cultured, Collagen, Cross-Linking Reagents, Dose-Response Relationship, Drug, Female, Materials Testing, Rabbits, Temperature, Time Factors, Porosity, Compressive Strength, Tissue Engineering, Iridoids, Chitosan, Tissue Scaffolds, Iridoid Glycosides

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review