Pulse oximetry-derived respiratory rate in general care floor patients
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Respiratory rate is recognized as a clinically important parameter for monitoring respiratory status on the general care floor (GCF). Currently, intermittent manual assessment of respiratory rate is the standard of care on the GCF. This technique has several clinically-relevant shortcomings, including the following: (1) it is not a continuous measurement, (2) it is prone to observer error, and (3) it is inefficient for the clinical staff. We report here on an algorithm designed to meet clinical needs by providing respiratory rate through a standard pulse oximeter. Finger photoplethysmograms were collected from a cohort of 63 GCF patients monitored during free breathing over a 25-min period. These were processed using a novel in-house algorithm based on continuous wavelet-transform technology within an infrastructure incorporating confidence-based averaging and logical decision-making processes. The computed oximeter respiratory rates (RRoxi) were compared to an end-tidal CO2 reference rate (RRETCO2). RRETCO2 ranged from a lowest recorded value of 4.7 breaths per minute (brpm) to a highest value of 32.0 brpm. The mean respiratory rate was 16.3 brpm with standard deviation of 4.7 brpm. Excellent agreement was found between RRoxi and RRETCO2, with a mean difference of -0.48 brpm and standard deviation of 1.77 brpm. These data demonstrate that our novel respiratory rate algorithm is a potentially viable method of monitoring respiratory rate in GCF patients. This technology provides the means to facilitate continuous monitoring of respiratory rate, coupled with arterial oxygen saturation and pulse rate, using a single non-invasive sensor in low acuity settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Incidence, reversal, and prevention of opioid-induced respiratory depression
Dahan, A., Aarts, L., & Smith, T. W. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181c38c25 · Cited by 634
Photoplethysmographic derivation of respiratory rate: A review of relevant physiology
Meredith, D. J., Clifton, D., Charlton, P., Brooks, J., Pugh, C. W., & Tarassenko, L. (2012) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2011.638965 · Cited by 226
Addison, P. S., Watson, J. N., Mestek, M. L., & Mecca, R. S. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9332-y · Cited by 97
Self-citationAllen, J., Frame, J. R., & Murray, A. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/2/312 · Cited by 86
Nilsson, L., Johansson, A., & Kalman, S. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/4/009 · Cited by 55
Cited by
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“Beside these three primary methods, other technologies are being used to get respiratory waveform: accelerometers [30]; extracted from the ECG signal [31]; derived from pulse oximetry [32] polymer-based transducers sensors [33]; optical fibers [34]; etc.”
MethodBreathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
“Validation studies assess BR algorithms to determine whether they are suitable for a particular application [43].”
BackgroundCharlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
Flexible graphene photodetectors for wearable fitness monitoring
Polat, E. O., Mercier, G., Nikitskiy, I., Puma, E., Galan, T., Gupta, S., Montagut, M., Piqueras, J. J., Bouwens, M., Durduran, T., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw7846 · Cited by 298
Recent development of respiratory rate measurement technologies
Liu, H., Allen, J., Zheng, D., & Chen, F. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab299e · Cited by 266
Metadata
- Authors
- Addison, P. S., Watson, J. N., Mestek, M. L., Ochs, J. P., Uribe, A. A., & Bergese, S. D.
- Venue
- Journal of Clinical Monitoring and Computing
- Published
- 2014-05-06
- Volume
- 29
- Issue
- 1
- Pages
- 113-120
- ISSN
- 1387-1307 (ISSN-L)
- 1573-2614
- OpenAlex
- W2057211515
- Cited by
- 69
- References
- 5
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.