The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Suprachoroidal Drug Delivery to the Back of the Eye Using Hollow Microneedles
Open accessAbstract
Purpose In this work, we tested the hypothesis that microneedles provide a minimally invasive method to inject particles into the suprachoroidal space for drug delivery to the back of the eye.Methods A single, hollow microneedle was inserted into the sclera, and infused nanoparticle and microparticle suspensions into the suprachoroidal space. Experiments were performed on whole rabbit, pig, and human eyes ex vivo. Particle delivery was imaged using brightfield and fluorescence microscopy as well as microcomputed tomography.Results Microneedles were shown to deliver sulforhodamine B as well as nanoparticle and microparticle suspensions into the suprachoroidal space of rabbit, pig, and human eyes. Volumes up to 35 μL were administered consistently. Optimization of the delivery device parameters showed that microneedle length, pressure, and particle size played an important role in determining successful delivery into the suprachoroidal space. Needle lengths of 800-1,000 μm and applied pressures of 250-300 kPa provided most reliable delivery.Conclusions Microneedles were shown for the first time to deliver nanoparticle and microparticle suspensions into the suprachoroidal space of rabbit, pig and human eyes. This shows that microneedles may provide a minimally invasive method for controlled drug delivery to the back of the eye.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This method has been successful in large-animal models and was demonstrated to be a safer approach in a phase 3 clinical trial to treat uveitis with macular edema [20,21].”
From The Ocular Gene Delivery Landscape (2021) · cites this paper as [20]
In the citing paper
“Its structural continuity and small volume are important for understanding the potential of the suprachoroidal space as a drug delivery route, which allows for rapid dissemination of a small amount of agent around most of the eye [305].”
From Bruch’s Membrane: A Key Consideration with Complement-Based Therapies for Age-Related Macular Degeneration (2023) · cites this paper as [305]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,479
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Self-citationIntraocular pressure in an American community. The Beaver Dam Eye Study.
Klein, R., Klein, R., & Linton, K. L. P. (1992) · PubMed · Cited by 429
Current and future ophthalmic drug delivery systems
del Amo, E. M., & Urtti, A. O. (2008) · Drug Discovery Today · doi:10.1016/j.drudis.2007.11.002 · Cited by 424
Silicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Hollow Metal Microneedles for Insulin Delivery to Diabetic Rats
Davis, S. P., Martanto, W., Allen, M. G., & Prausnitz, M. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845240 · Cited by 407
Self-citationDamme, P. V., Kafeja, F., der Wielen, M. V., Almagor, Y., Sharon, O., & Levin, Y. (2008) · Vaccine · doi:10.1016/j.vaccine.2008.10.077 · Cited by 331
Microinfusion Using Hollow Microneedles
Martanto, W., Moore, J. S., Kashlan, O. N., Kamath, R., Wang, P. M., O'Neal, J. M., & Prausnitz, M. R. (2005) · Pharmaceutical Research · doi:10.1007/s11095-005-8498-8 · Cited by 262
Self-citationINTRAVITREAL INJECTION OF THERAPEUTIC AGENTS
PEYMAN, G. A., LAD, E. M., & MOSHFEGHI, D. M. (2009) · Retina · doi:10.1097/iae.0b013e3181a94f01 · Cited by 255
Corneal and scleral collagens—a microscopist’s perspective
Meek, K. M., & Fullwood, N. J. (2001) · Micron · doi:10.1016/s0968-4328(00)00041-x · Cited by 247
Cited by
Sorted by citations
Items 301–330 of 330
Development of Microneedle Devices for Drug Delivery
HOWELLS, O. (2021) · doi:10.23889/suthesis.58289
An Update on Suprachoroidal Corticosteroid Injections in the Management of Macular Edema
Ismail, O. M., & Henry, C. R. (2022) · Current Ophthalmology Reports · doi:10.1007/s40135-022-00291-7
New Avenues of Delivery (Subretinal Gene Therapy, Port Delivery, Suprachoroidal)
Nair, A. A., Chaili, S., & Law, J. C. (2023) · Current practices in ophthalmology · doi:10.1007/978-981-99-1661-0_19
Can Microneedles Revolutionize Ocular Drug Delivery?
Šahinović, M., Tucak, A., Muhamedagić, K., Hindija, L., Rahić, O., Hadžiabdić, J., Vranić, E., & Çekiç, A. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-49062-0_46
Microneedles deliver drugs to ophthalmic tissue
Nguyen, T. T., & Vo, G. V. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13881-2.00003-5
Rajendran, N. (2024) · doi:10.23889/suthesis.67185
Mano, F., LoBue, S., Tailor, P. D., & Olsen, T. W. (2024) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2024.08.002
Microneedle delivery of stem cell derived retinal pigment epithelial cellsPreprint
Ching, J., Ichikawa, H., Kitahata, S., Morrow, L. C., & Kadonosono, K. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.04.29.651158
Hollow-Microneedles-Based Injectable Delivery System
Abedi, M., Ghasemi, Y., & Ranjbar, S. (2025) · Series in bioengineering · doi:10.1007/978-981-96-3916-8_3
Microneedles in ophthalmology: minimally invasive alternative to traditional methods. Review
Hmaidi, E., Sementsov, K. O., Zernov, I. A., Dikinov, A. Z., Garaeva, D. A., Kholkina, K. A., Tikhanovich, E. D., Lovushkina, A. A., Gumerova, E. R., Lilikov, K. A., et al. (2025) · Ophthalmology Reports · doi:10.17816/ov677111
Emerging trends in ophthalmic products: Microneedles, hydrogels, and ocular inserts
Datta, D., Bandi, S. P., Ananya Prabha, H., Halagali, P., Tippavajhala, V. K., & Rathee, A. S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-33781-9.00013-7
Design and Development of a Suprachoroidal Spacer Implant and Injector System for Glaucoma Treatment
Jang, K., Ross, A. K. M., Onyekwere, O. G., Goldberg, J. L., Myung, D. J., & Chiang, B. (2026) · ACS Applied Bio Materials · doi:10.1021/acsabm.5c01876
Goyal, S., & Vanita, V. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-43986-5.00042-4
Huang, B., Xu, W., Qiu, X., Ye, B., Wan, Z., Luo, X., Feng, B., Xiang, S., Nan, K., & Lin, S. (2026) · Biomaterials · doi:10.1016/j.biomaterials.2026.124252 · Cited by 1
Navratil, E., & Mullins, R. F. (2026) · Handbook of clinical neurology · doi:10.1016/b978-0-443-22193-4.00003-2
Topotecan Microneedle Scleral Patch: A Transscleral Drug Delivery Study for Retinoblastoma
Raval, V., Arawindh, R., Naik, S., Jakati, S., & Venuganti, V. V. K. (2026) · Ophthalmology Science · doi:10.1016/j.xops.2026.101226
Nguyen, V. P., Zheng, M., Lee, Y., Park, S., Dang, C., Tran, K., Wei, Z., Yang, D., & Paulus, Y. M. (2026) · Experimental Eye Research · doi:10.1016/j.exer.2026.111060
Stem cell therapy in retinal disease
WANG, J., Felfeli, T., & Ballios, B. G. (2026) · Handbook of clinical neurology · doi:10.1016/b978-0-443-22212-2.00004-5
Mir, T. A., Scott, I. U., & Kim, S. J. (2026) · Handbook of clinical neurology · doi:10.1016/b978-0-443-22212-2.00014-8
Raj, D., Subramony, A., Sabitha, M., & Nair, S. C. (2026) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2026.108570
Mirando, A. C., Silva, R. L. E., Shen, J., Robinson, T. J., Green, J. J., Campochiaro, P. A., Popel, A. S., & Pandey, N. B. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.06.30.735614
Ahmadian, Z., & Kaji, H. (2026) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2026.119791
From drops to devices: microneedle-mediated ocular drug delivery for improved therapeutic outcomes
Kumar, D., Kumar, A., Mujtaba, M. A., Patil, D. R., Singh, T. G., Awasthi, A., & Kumar, M. (2026) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2026.127260
Local therapy in uveitis: Current concepts and emerging strategies
Jain, T., Goel, P., & Agarwal, M. (2026) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_2906_25
Hollow Microneedles in Ophthalmology: From Drug Delivery to Integrated Biosensing
Sun, F., Xiao, C., Wang, Z., Hu, W., Peng, Z., Wong, Z. J., Tan, Z., & Cui, B. (2026) · Small · doi:10.1002/smll.75520
Li, M., An, Q., Fang, T., Zhang, M., Wu, C., Zhou, Y., Zhao, F., Li, Y., Dong, X., Zhao, X., et al. (2026) · Journal of Analysis and Testing · doi:10.1007/s41664-026-00504-z
Suprachoroidal triamcinolone acetonide for macular edema: A systematic review of efficacy and safety
Hedhiri, M. H., Oueslati, Y., Lajmi, H., Laajimi, F., Mbarek, S., Mahmoud, A., & Messaoud, R. (2026) · Journal Français d Ophtalmologie · doi:10.1016/j.jfo.2026.105010
Recent advances and future prospects in nanotechnology-based ocular drug delivery systems
Mahirah, S., Yazhini, N., Harikrishnan, N., Saloniya, G., & Solomon, V. R. (2026) · Next research. · doi:10.1016/j.nexres.2026.102620
Metadata
- Authors
- Patel, S. R., Lin, A. S. P., Edelhauser, H. F., & Prausnitz, M. R.
- Affiliations
- Georgia Institute of Technology (US)
- Emory University (US)
- Corresponding author
- Edelhauser, Henry F.
- Prausnitz, Mark R.
- Venue
- Pharmaceutical Research
- Published
- 2010-09-21
- Volume
- 28
- Issue
- 1
- Pages
- 166-176
- ISSN
- 0724-8741 (ISSN-L)
- 1573-904X
- PMC
- PMC3038673
- OpenAlex
- W1977812165
- Cited by
- 330
- References
- 27
- Citations by year
- 2026: 21 · 2025: 26 · 2024: 30 · 2023: 24 · 2022: 17 · 2021: 31 · 2020: 26 · 2019: 18 · 2018: 19 · 2017: 22 · 2016: 25 · 2015: 19 · 2014: 14 · 2013: 13 · 2012: 16
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Pharmaceutical Research (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Eye Institute (R24EY017045)
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
- Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
- Keywords
- hollow microneedles, nanoparticle delivery, microparticle delivery, sclera, sulforhodamine B, injection pressure, needle length, particle size
- MeSH terms
- Animals, Choroid, Drug Carriers, Pharmaceutical Preparations, Humans, Intraocular Pressure, Microinjections, Microscopy, Fluorescence, Needles, Rabbits, Retina, Sclera, Swine, Drug Delivery Systems, Nanoparticles, Injections, Intraocular, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review