Cited by 81Medical Imaging Techniques and ApplicationsNeurotransmitter Receptor Influence on BehaviorRadiopharmaceutical Chemistry and Applications

Translational neuroimaging: positron emission tomography studies of monoamine oxidase

Fowler, Joanna S., Logan, Jean, Volkow, Nora D., Wang, Gene-Jack·2005·Molecular Imaging and Biology

Abstract

Positron emission tomography (PET) using radiotracers with high molecular specificity is an important scientific tool in studies of monoamine oxidase (MAO), an important enzyme in the regulation of the neurotransmitters dopamine, norepinephrine, and serotonin as well as the dietary amine, tyramine. MAO occurs in two different subtypes, MAO A and MAO B, which have different substrate and inhibitor specificity and which are different gene products. The highly variable subtype distribution with different species makes human studies of special value. MAO A and B can be imaged in the human brain and certain peripheral organs using PET and carbon-11 (half-life 20.4 minutes) labeled mechanism-based irreversible inhibitors, clorgyline and L -deprenyl, respectively. In this article we introduce MAO and describe the development of these radiotracers and their translation from preclinical studies to the investigation of variables affecting MAO in the human brain and peripheral organs.

Integrity signals

Registry

Crossref · 10.1007/s11307-005-0016-1

Cites

0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Fowler, J. S., Logan, J., Volkow, N. D., & Wang, G.-J.
Affiliations
  • Brookhaven National Laboratory (US)
  • National Institutes of Health (US)
Corresponding author
Fowler, Joanna S.
Venue
Molecular Imaging and Biology
Published
2005-11
Volume
7
Issue
6
Pages
377-387
ISSN
  • 1536-1632 (ISSN-L)
  • 1860-2002
OpenAlex
W2025109436
Cited by
81
References
0
Citations by year
2026: 2 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 7 · 2019: 1 · 2018: 7 · 2017: 7 · 2016: 4 · 2015: 4 · 2014: 8 · 2013: 7 · 2012: 7
FWCI
0.30
Type
journal article
Language
en
Open access
closed
Locations
  • Molecular Imaging and Biology (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institute on Drug Abuse (K05DA020001)
  • National Institute of Biomedical Imaging and Bioengineering (R01EB002630, EB2630)
  • National Center for Research Resources (#M01RR10710, M01RR010710)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neurotransmitter Receptor Influence on Behavior
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
Keywords
monoamine oxidase, monoamine oxidase A, monoamine oxidase B, positron emission tomography, radioactive tracers, clorgyline, selegiline, carbon-11, human brain imaging, peripheral organs, neurotransmitter modulation, tyramine
MeSH terms
Aging, Animals, Humans, Monoamine Oxidase, Monoamine Oxidase Inhibitors, Neurons, Parkinson Disease, Positron-Emission Tomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review