Efficacy and patient satisfaction with autoadjusting CPAP with variable expiratory pressure vs standard CPAP: a two-night randomized crossover trial
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Expiratory pressure relief (C-Flex) technology monitors the patient's airflow during expiration and reduces the pressure in response to the patient. Increased comfort levels associated with C-Flex therapy have potential to improve patient adherence to therapy. The purpose of this study was to assess the combination of autoadjusting CPAP (APAP) and C-Flex in terms of (1) treatment efficacy, and (2) patient preference when compared to standard CPAP. Fifteen patients who had previously undergone formal CPAP titration polysomnography were treated with either one night of the APAP with C-Flex or one night of conventional CPAP, in a crossover trial. Patient satisfaction levels were recorded using visual analog scales (VAS) on the morning after the study. Mean patient age was 50 +/- 12 years, body mass index (BMI) was 36 +/- 6 kg/m(2), baseline AHI was 53 +/- 31 events/h, and CPAP Pressure was 11 +/- 2 cm/H(2)O. APAP with C-Flex was as effective as CPAP, with no differences detected in sleep latency (17 +/- 5 vs 12.3 +/- 3 min, p = 0.4), or respiratory indices (AHI of 4.2 +/- 2 vs 2.4 +/- 0.7 events/h, p = 0.1). VAS scores (scale 0-10) indicated a trend towards increased patient satisfaction while using APAP with C-Flex (7.9 vs 7.2, p = 0.07). 10 patients expressed a preference for APAP with C-Flex (VAS, 0 to 10) over standard CPAP (total positive score of 68, mean score of 4.8 +/- 4.3). One patient expressed no preference. Four patients expressed a preference for CPAP (total positive score of 13, mean score of 0.9 +/- 1.9) (APAP with C-Flex vs standard CPAP, p < 0.01 paired t test). APAP with C-Flex eliminates sleep disordered breathing as effectively as standard CPAP. Patients indicated a preference for APAP with C-Flex suggesting a possible advantage in terms of patient adherence for this mode of treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
HOY, C. J., VENNELLE, M., KINGSHOTT, R. N., ENGLEMAN, H. M., & DOUGLAS, N. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9808008 · Cited by 379
Massie, C. A., Hart, R. W., Peralez, K., & Richards, G. N. (1999) · Chest · doi:10.1378/chest.116.2.403 · Cited by 308 · cited 1×
“heated humidification, and mask adjustments [6–11].”
Compliance With Nasal CPAP Can Be Improved by Simple Interventions
Chervin, R. D., Theut, S., Bassetti, C., & Aldrich, M. S. (1997) · Sleep · doi:10.1093/sleep/20.4.284 · Cited by 242 · cited 1×
“heated humidification, and mask adjustments [6–11].”
Comparison between Automatic and Fixed Positive Airway Pressure Therapy in the Home
Massie, C. A., McArdle, N., Hart, R. W., Schmidt-Nowara, W. W., Lankford, A., Hudgel, D. W., Gordon, N., & Douglas, N. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200201-022oc · Cited by 177 · cited 1×
“Although this metaanalysis did not demonstrate a significant improvement in compliance with APAP, other studies have suggested that APAP may be preferred by patients, especially if their baseline CPAP pressures are elevated [20].”
ResultComparison of nose and face mask CPAP therapy for sleep apnoea
Mortimore, I. L., Whittle, A. T., & Douglas, N. J. (1998) · Thorax · doi:10.1136/thx.53.4.290 · Cited by 149
Hassaballa, H. A., Tulaimat, A., Herdegen, J. J., & Mokhlesi, B. (2005) · Sleep And Breathing · doi:10.1007/s11325-005-0033-y · Cited by 142 · cited 1×
“CPAP is effective in reducing sleep fragmentation, resolving nocturnal desaturation, and improving daytime sleepiness [1]; moreover, CPAP is a costeffective use of healthcare resources, and may reduce risks of motor vehicle crashes and the development of cardiovascular morbidity [2–5].”
BackgroundHukins, C. (2004) · Sleep · doi:10.1093/sleep/27.8.1512 · Cited by 100
The role of telemedicine in CPAP compliance for patients with obstructive sleep apnea syndrome
Taylor, Y., Eliasson, A., Andrada, T., Kristo, D., & Howard, R. (2006) · Sleep and Breathing · doi:10.1007/s11325-006-0059-9 · Cited by 96
West, S. D. (2006) · Thorax · doi:10.1136/thx.2005.046300 · Cited by 93 · cited 1×
“Furthermore, APAP may be useful for ambulatory titration of CPAP pressure in patients in whom in-laboratory therapy titration is either delayed or impossible [13–15].”
Background
Cited by
Task Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749
Smith, I., & Lasserson, T. J. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub3 · Cited by 151
Positive Pressure Therapy: A Perspective on Evidence-based Outcomes and Methods of Application
Sanders, M. H., Montserrat, J. M., Farré, R., & Givelber, R. J. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200709-150mg · Cited by 75
Vennelle, M., White, S., Riha, R. L., Mackay, T. W., Engleman, H. M., & Douglas, N. J. (2010) · Sleep · doi:10.1093/sleep/33.2.267 · Cited by 74
Metadata
- Authors
- Mulgrew, A. T., Cheema, R., Fleetham, J., Ryan, C. F., & Ayas, N. T.
- Venue
- Sleep and Breathing
- Published
- 2006-10-20
- Volume
- 11
- Issue
- 1
- Pages
- 31-37
- ISSN
- 1520-9512 (ISSN-L)
- 1522-1709
- OpenAlex
- W2025164727
- Cited by
- 53
- References
- 10
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy and patient satisfaction with autoadjusting CPAP with variable expiratory pressure vs standard CPAP: a two-night randomized crossover trial. https://app.cochat.ai/papers/10.1007/s11325-006-0078-6
- The paper
- Mulgrew, A. T., Cheema, R., Fleetham, J., Ryan, C. F., & Ayas, N. T. (2007). Efficacy and patient satisfaction with autoadjusting CPAP with variable expiratory pressure vs standard CPAP: a two-night randomized crossover trial. Sleep and Breathing. https://doi.org/10.1007/s11325-006-0078-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.