CoChat

Diagnosis of sleep apnea in patients with stable chronic heart failure using a portable sleep test diagnostic device

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

Purpose ApneaLink is a portable device for the screening of sleep apnea, a prevalent and underdiagnosed comorbidity in heart failure patients. A prospective cross-sectional study in patients with chronic heart failure was carried out to assess the sensitivity and specificity of apnea-hypopnea index (AHI) measurements using ApneaLink against the standard polysomnography test. Methods Adult patients with a prior hospitalization in an acute heart failure hospital unit were recruited for the study. All participants were tested for sleep apnea using ApneaLink and polysomnography simultaneously during an overnight stay at a sleep laboratory. Global sleep apnea was evaluated according to the AHI, which was analyzed and compared. Subpopulation comparison based on ejection fraction was not realized due to population size. Results Thirty-five patients with stable chronic heart failure completed the study (mean age 70.9 ± 10.5 years and body mass index 30.0 ± 4.7 kg/m 2 ). Two patients were excluded due to insufficient study duration. ApneaLink had a sensitivity greater than 80% for all AHI measurements, and a specificity greater than 80% for all AHI measurements, except for AHI ≥ 5 events/h (61.5%). The results showed higher sensitivities and specificities at AHI values of ≥ 10 events/h (sensitivity 81.3% and specificity 84.2%) and ≥ 15 events/h (sensitivity 83.3% and specificity 91.3%). Correlation analysis showed that AHI measurements using ApneaLink and polysomnography had a strong…

Overview

Integrity signals

Registry

Crossref · 10.1007/s11325-017-1607-1

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 18

Metadata

Authors
Araújo, I., Marques, F., André, S., Araújo, M., Marques, S., Ferreira, R., Moniz, P., Proença, M., Borrego, P., & Fonseca, C.
Affiliations
  • Hospital de Egas Moniz (PT)
  • University of Lisbon (PT)
Corresponding author
Araújo, Inês
Venue
Sleep and Breathing
Published
2018-01-17
Volume
22
Issue
3
Pages
749-755
ISSN
  • 1520-9512 (ISSN-L)
  • 1522-1709
OpenAlex
W2784734657
Cited by
18
References
39
Citations by year
2025: 2 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 5 · 2020: 2 · 2019: 2 · 2018: 1
FWCI
1.71
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Sleep And Breathing (publishedVersion)
  • PubMed (publishedVersion)
Funders
European Society of Cardiology
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
sleep apnea, chronic heart failure, ApneaLink, home sleep monitoring, apnea-hypopnea index, polysomnography, sensitivity and specificity, heart failure comorbidity
MeSH terms
Aged, Chronic Disease, Cross-Sectional Studies, Female, Heart Failure, Humans, Male, Prospective Studies, Sleep Apnea Syndromes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.