Empirical mode decomposition: a novel technique for the study of tremor time series
The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.
Abstract
Tremor is a clinical feature characterized by oscillations of a part of the body. The detection and study of tremor is an important step in investigations seeking to explain underlying control strategies of the central nervous system under natural (or physiological) and pathological conditions. It is well established that tremorous activity is composed of deterministic and stochastic components. For this reason, the use of digital signal processing techniques (DSP) which take into account the nonlinearity and nonstationarity of such signals may bring new information into the signal analysis which is often obscured by traditional linear techniques (e.g. Fourier analysis). In this context, this paper introduces the application of the empirical mode decomposition (EMD) and Hilbert spectrum (HS), which are relatively new DSP techniques for the analysis of nonlinear and nonstationary time-series, for the study of tremor. Our results, obtained from the analysis of experimental signals collected from 31 patients with different neurological conditions, showed that the EMD could automatically decompose acquired signals into basic components, called intrinsic mode functions (IMFs), representing tremorous and voluntary activity. The identification of a physical meaning for IMFs in the context of tremor analysis suggests an alternative and new way of detecting tremorous activity. These results may be relevant for those applications requiring automatic detection of tremor. Furthermore, th…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“On the contrary, solid state gyroscopes provide a direct measurement of a rotational movement, uninfluenced by gravity [24], but affected by a characteristic low frequency bias.”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [24]
In the citing paper
“On the contrary, solid state gyroscopes provide a direct measurement of a rotational movement, uninfluenced by gravity [24], but affected by a characteristic low frequency bias.”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [24]
In the citing paper
“voluntary [24,25] or artificially elicited [26] muscle contractions affect the severity of the tremor, by generating forces on the musculoskeletal system.”
From A neuroprosthesis for tremor management through the control of muscle co-contraction (2013) · cites this paper as [25]
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Parkinson’s Disease and Movement Disorders
(2005) · Jaypee Brothers Medical Publishers (P) Ltd. eBooks · doi:10.5005/jp/books/10587 · Cited by 798
Computing the discrete-time "analytic" signal via FFT
Marple, L. (1999) · IEEE Transactions on Signal Processing · doi:10.1109/78.782222 · Cited by 753
Deuschl, G., Raethjen, J., Lindemann, M., & Krack, P. (2001) · Muscle & Nerve · doi:10.1002/mus.1063 · Cited by 508
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460 · cited 1×
“The gyroscopes could therefore be attached to a convenient position in order to avoid areas of skin and muscle movement [30].”
BackgroundIntroduction to Hilbert spaces with applications
(1991) · Choice Reviews Online · doi:10.5860/choice.28-2767 · Cited by 373
Parkinson's Disease and Movement Disorders
Goetz, C. G. (1998) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.280.20.1796-a · Cited by 315
Movement disorders : neurologic principles and practice
Watts, R. L., & Koller, W. C. (1997) · McGraw-Hill, Health Professions Division eBooks · Cited by 255
Movement Disorders: Neurologic Principles and Practice
O'Suilleabhain, P. E. (1997) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(11)63690-2 · Cited by 226
Characteristics of physiologic tremor in young and elderly adults
Elble, R. J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00006-3 · Cited by 163
Huang, N. E. (2004) · Bulletin of the Seismological Society of America · doi:10.1785/0120000735 · Cited by 162
20 - Biomedical Signal Processing
Chang, H., & Moura, J. M. F. (2005) · IEEE Statistical Signal Processing Workshop (SSP) · doi:10.1109/ssp.2005.1628735 · Cited by 157
Tremor disorders. Diagnosis and management.
Anouti, A., & Koller, W. C. (1995) · PubMed Central · Cited by 139
Pathological tremors: deterministic chaos or nonlinear stochastic oscillators?
Timmer, J., Häussler, S., Lauk, M., & Lücking, C.-H. (2000) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166494 · Cited by 130
Cross-spectral analysis of physiological tremor and muscle activity
Timmer, J., Lauk, M., Pfleger, W., & Deuschl, G. (1998) · Biological Cybernetics · doi:10.1007/s004220050439 · Cited by 126
Characteristics of hand tremor time series
Timmer, J., Gantert, C., Deuschl, G., & Honerkamp, J. (1993) · Biological Cybernetics · doi:10.1007/bf00202568 · Cited by 112
Introduction to Hilbert Spaces with Applications
SRJ, Debnath, L., & Mikusiński, P. (1999) · Journal of the American Statistical Association · doi:10.2307/2669970 · Cited by 110
Pathological tremor management: modelling, compensatory technology and evaluation
Rocon, E., Belda-Lois, J. M., Sanchez-Lacuesta, J. J., & Pons, J. L. (2004) · Technology and Disability · doi:10.3233/tad-2004-16102 · Cited by 89 · cited 5×
“Although the most common types of tremor have been subject of numerous studies, their mechanisms and origins are still unknown [16, 19, 25].”
BackgroundMethodInfluentialSelf-citationUsing Time Domain Characteristics to Discriminate Physiologic and Parkinsonian Tremors
Edwards, R., & Beuter, A. (2000) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200001000-00009 · Cited by 74
Analyzing the dynamics of hand tremor time series
Gantert, C., Honerkamp, J., & Timmer, J. (1992) · Biological Cybernetics · doi:10.1007/bf00204112 · Cited by 74
Undar, A. (1994) · Control Engineering Practice · doi:10.1016/0967-0661(94)90562-2 · Cited by 74
Detection and Estimation Methods for Biomedical Signals
Akay, M. (1996) · Medical Entomology and Zoology · Cited by 67
Using Frequency Domain Characteristics to Discriminate Physiologic and Parkinsonian Tremors
Beuter, A., & Edwards, R. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199909000-00010 · Cited by 50
Learning and validation of human control strategies
Nechyba, M. C., & Xu, Y. (1998) · Cited by 36
Decomposition and Analysis of Electromyographic Signals
AdO, A. (2005) · OpenGrey (Institut de l'Information Scientifique et Technique) · doi:10.13140/rg.2.2.33350.06727 · Cited by 33
Pathological tremors as diffusional processes
Gao, J., & Tung, W. (2002) · Biological Cybernetics · doi:10.1007/s00422-001-0296-8 · Cited by 28
A novel spectral representation of electromyographic signals
Andrade, A. D. O., Kyberd, P., & Taffler, S. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280447 · Cited by 23
Self-citationPathological tremors: Deterministic chaos or nonlinear stochastic oscillators?
Timmer, J. (2000) · AIP conference proceedings · doi:10.1063/1.1302385 · Cited by 9
Research works printed but not linked: 5
- Ang WT (2004) Active Control compensation in Handheld Instrument for Microsurgery. PhD thesis, Johns Hopkins University
- Elble RJ, Koller WC (1990) Tremor. The Johns Hopkins University Press, Baltimore
- Riviere C (1981) Adaptive suppression of tremor for improved human–machine control. PhD thesis, Johns Hopkins University, Baltimore
- Rocon E, Ruiz AF, Pons JL (2005) On the use of rate gyroscopes for tremor sensing in the human upper limb. In: Proceedings of the international conference eurosensors XIX, p MP30
- Timmer J, Lauk M, Deuschl G (1998) Cross-spectral analysis of physiological tremor and muscle activity. I. Theory and application to unsynchronized electromyogram. Biol Cybern 78:349–357 · DOI · Paper page
Cited by
A Review on Techniques for Tremor Recording and Quantification
Mansur, P. H. G., Cury, L. K. P., Andrade, A. O., Pereira, A. A., Miotto, G. A. A., Soares, A. B., & Naves, E. L. M. (2007) · Critical Reviews™ in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v35.i5.10 · Cited by 100
Self-citationMenegoni, F., Milano, E., Trotti, C., Galli, M., Bigoni, M., Baudo, S., & Mauro, A. (2008) · European Journal of Neurology · doi:10.1111/j.1468-1331.2008.02396.x · Cited by 110
Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data
Gallego, J., Rocon, E., Roa, J. O., Moreno, J., & Pons, J. L. (2010) · Sensors · doi:10.3390/s100302129 · Cited by 107
Self-citationDecomposing time series into deterministic and stochastic influences: A survey
Duarte, F. S. L. G., Rios, R. A., Hruschka, E. R., & de Mello, R. F. (2019) · Digital Signal Processing · doi:10.1016/j.dsp.2019.102582 · Cited by 103
Transducer‐based evaluation of tremor
Haubenberger, D., Abbruzzese, G., Bain, P. G., Bajaj, N., Benito‐León, J., Bhatia, K. P., Deuschl, G., Forjaz, M. J., Hallett, M., Louis, E. D., et al. (2016) · Movement Disorders · doi:10.1002/mds.26671 · Cited by 87
Metadata
- Authors
- de Lima, E. R., Andrade, A. O., Pons, J. L., Kyberd, P., & Nasuto, S. J.
- Affiliations
- University of New Brunswick (CA)
- University of Reading (GB)
- Venue
- Medical and Biological Engineering and Computing
- Published
- 2006-06-20
- Volume
- 44
- Issue
- 7
- Pages
- 569-582
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W1971961039
- Cited by
- 93
- References
- 29
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 6 · 2022: 3 · 2021: 2 · 2020: 4 · 2019: 6 · 2018: 6 · 2017: 4 · 2016: 8 · 2015: 7 · 2014: 11 · 2013: 12 · 2012: 2
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- tremor, empirical mode decomposition, Hilbert spectrum, intrinsic mode functions, tremor detection, voluntary movement, neurological disorders, functional assessment
- MeSH terms
- Adult, Aged, Aged, 80 and over, Algorithms, Arm, Diagnosis, Computer-Assisted, Humans, Middle Aged, Movement, Signal Processing, Computer-Assisted, Tremor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.