The DOI matches its Crossref record; 220 of the 227 references it cites were found in a registry or an index.
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Abstract
Electrodes serve as the first critical interface to the biological organ system. In neuroprosthetic applications, for example, electrodes interface to the tissue for either signal recording or tissue stimulation. In this review, we consider electrodes for recording neural activity. Recording electrodes serve as wiretaps into the neural tissues, providing readouts of electrical activity. These signals give us valuable insights into the organization and functioning of the nervous system. The recording interfaces have also shown promise in aiding treatment of motor and sensory disabilities caused by neurological disorders. Recent advances in fabrication technology have generated wide interest in creating tiny, high-density electrode interfaces for neural tissues. An ideal electrode should be small enough and be able to achieve reliable and conformal integration with the structures of the nervous system. As a result, the existing electrode designs are being shrunk and packed to form small form factor interfaces to tissue. Here, an overview of the historic and state-of-the-art electrode technologies for recording neural activity is presented first with a focus on their development road map. The fact that the dimensions of recording electrode sites are being scaled down from micron to submicron scale to enable dense interfaces is appreciated. The current trends in recording electrode technologies are then reviewed. Current and future considerations in electrode design, including the use of inorganic nanostructures and biologically inspired or biocomapatible materials are discussed, along with an overview of the applications of flexible materials and transistor transduction schemes. Finally, we detail the major technical challenges facing chronic use of reliable recording electrode technology.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Novel approaches were demonstrated previously, and recently one of the research trends of the neural interface is to combine with neural tissue or biodegradable materials for long-term use or removing additional surgery.21,111,112”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [112]
Citations
Cites
Items 201–220 of 220
Mathews, K. S., Wark, H. A. C., & Normann, R. A. (2014) · Muscle & Nerve · doi:10.1002/mus.24171 · Cited by 26
An Implantable Microactuated Intrafascicular Electrode for Peripheral Nerves
Bossi, S., Kammer, S., DÖrge, T., Menciassi, A., Hoffmann, K. P., & Micera, S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2031169 · Cited by 26
Extracellular Wire Tetrode Recording in Brain of Freely Walking Insects
Guo, P., Pollack, A. J., Varga, A. G., Martin, J. P., & Ritzmann, R. E. (2014) · Journal of Visualized Experiments · doi:10.3791/51337 · Cited by 25
Electrode Failure: Tissue, Electrical, and Material Responses
Streit, W. J., Xue, Q., Prasad, A., Sankar, V., Knott, E. P., Dyer, A. L., Reynolds, J. R., Nishida, T., Shaw, G. P., & Sanchez, J. C. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2175632 · Cited by 25
Time to address the problems at the neural interface
Durand, D. M., Ghovanloo, M., & Krames, E. S. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/020201 · Cited by 24
Zheng, X., Zhang, J., Chen, T., & Chen, Z. (2003) · Microsurgery · doi:10.1002/micr.10116 · Cited by 23
Greenwald, E., Masters, M. R., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1452-6 · Cited by 23
Self-citationPresident Obama Announces the BRAIN Initiative
Weiss, P. S. (2013) · ACS Nano · doi:10.1021/nn401796f · Cited by 19
Bifurcating microchannels as a scaffold to induce separation of regenerating neurites
Wieringa, P. A., Wiertz, R. W. F., de Weerd, E. L., & Rutten, W. L. C. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/1/016001 · Cited by 18
Stoyanova, I. I., van Wezel, R. J. A., & Rutten, W. L. C. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066018 · Cited by 18
Hoshino, T., Ozasa, A., Kometani, R., Suzuki, T., Matsui, S., & Mabuchi, K. (2006) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.2359730 · Cited by 15
Spontaneous unit-activity in the superficial cortical layers.
Woldring, S., & Dirken, M. N. J. (1950) · PubMed · Cited by 15
PERIPHERAL NERVE RECORDING ELECTRODES AND TECHNIQUES
Yoshida, K., & Riso, R. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0021 · Cited by 15
State-of-the-Art Microwire Array Design for Chronic Neural Recordings in Behaving Animals
Nicolelis, M. A. L., & Lehew, G. (2007) · Frontiers in neuroscience · doi:10.1201/9781420006414.ch1 · Cited by 15
Regenerative microchannel electrode array for peripheral nerve interfacing
Srinivasan, A., Guo, L., & Bellamkonda, R. V. (2011) · 2011 5th International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910535 · Cited by 12
Gierthmuehlen, M., Freiman, T. M., Haastert‐Talini, K., Mueller, A., Kaminsky, J., Stieglitz, T., & Plachta, D. T. T. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066191 · Cited by 8
Multi-unit recording with iridium oxide modified stereotrodes in Drosophila melanogaster
Zhong, C., Zhang, Y., He, W. J., Wei, P., Lu, Y., Zhu, Y., Liu, L., & Wang, L. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.11.013 · Cited by 7
The Role Of Materials In Designing Nerve Guidance Channels And Chronic Neural Interfaces
Valentini, R. F., & Aebischer, P. (1993) · Springer eBooks · doi:10.1007/978-3-642-58069-7_34 · Cited by 5
Elastomer-based microcable electrodes for electrophysiological applications
McClain, M. A. (2010) · SMARTech Repository (Georgia Institute of Technology) · Cited by 1
New Paradigms for Organic Catalysts: The First Organocatalytic Living Polymerization
Nederberg, F., Connor, E. F., Möller, M., Glauser, T., & Hedrick, J. L. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20010716)40:14
Flagged first, then by citations
7 of the 227 references couldn’t be matched to a known paper.
Research works printed but not linked: 4
- Marks A (1969) Bullfrog nerve regeneration into porous implants. Anatom Rec 163:226
- Schmidt E, McIntosh J, Durelli L, Bak M (1978) Fine control of operantly conditioned firing patterns of cortical neurons. Exp Neurol 61(2):349–369 · DOI
- Ward MP, Rajdev P, Ellison C, Irazoqui PP (2009) Toward a comparison of microelectrodes for acute and chronic recordings. Brain Res 1282:183–200 · DOI
- Wilks SJ, Richardson-Burns SM, Hendricks JL, Martin DC, Otto KJ (2009) Poly (3, 4-ethylenedioxythiophene) as a micro-neural interface material for electrostimulation. Front Neuroeng 2(7):1–8
Cited by
Sorted by citations
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Seizure prediction – ready for a new era
Kuhlmann, L., Lehnertz, K., Richardson, M. P., Schelter, B., & Zaveri, H. P. (2018) · Nature Reviews Neurology · doi:10.1038/s41582-018-0055-2 · Cited by 450
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Biocompatibility of Polyimides: A Mini-Review
Constantin, C.-P., Aflori, M., Damian, R. F., & Rusu, R. (2019) · Materials · doi:10.3390/ma12193166 · Cited by 203
Lee, S., Shi, Q., & Lee, C. (2019) · APL Materials · doi:10.1063/1.5063498 · Cited by 164
Metadata
- Authors
- Patil, A. C., & Thakor, N. V.
- Affiliations
- National University of Singapore (SG)
- Johns Hopkins University (US)
- Corresponding author
- Patil, Anoop C.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2016-01
- Volume
- 54
- Issue
- 1
- Pages
- 23-44
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2249190983
- Cited by
- 175
- References
- 227
- Citations by year
- 2026: 2 · 2025: 37 · 2024: 12 · 2023: 15 · 2022: 17 · 2021: 14 · 2020: 14 · 2019: 26 · 2018: 17 · 2017: 11 · 2016: 9
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National University of Singapore
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- neural recording electrodes, microelectrodes, nanoelectrodes, neuroprosthetics, biomaterials, biomimetic materials, inorganic nanostructures, flexible materials
- MeSH terms
- Animals, Brain, Humans, Man-Machine Systems, Microelectrodes, Prostheses and Implants, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review