The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis
Open accessAbstract
The potential of inertial measurement units (IMUs) for ergonomics applications appears promising. However, previous IMUs validation studies have been incomplete regarding aspects of joints analysed, complexity of movements and duration of trials. The objective was to determine the technological error and biomechanical model differences between IMUs and an optoelectronic system and evaluate the effect of task complexity and duration. Whole-body kinematics from 12 participants was recorded simultaneously with a full-body Xsens system where an Optotrak cluster was fixed on every IMU. Short functional movements and long manual material handling tasks were performed and joint angles were compared between the two systems. The differences attributed to the biomechanical model showed significantly greater (P ≤ .001) RMSE than the technological error. RMSE was systematically higher (P ≤ .001) for the long complex task with a mean on all joints of 2.8° compared to 1.2° during short functional movements. Definition of local coordinate systems based on anatomical landmarks or single posture was the most influent difference between the two systems. Additionally, IMUs accuracy was affected by the complexity and duration of the tasks. Nevertheless, technological error remained under 5° RMSE during handling tasks, which shows potential to track workers during their daily labour.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“RMSE results varied between less than 1° and 9°, showing good joint measurement validity [33,34,37,40,41].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“RMSE and correlation coefficients varied respectively from 0.2 to 9.3° and 0.53 to 1.00, showing fair to excellent validity [5,30,37,41,42,46,53,54,55,56,57,58,59].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“Validity was similar across all movement planes and axes [34,36,37,38,41,46,47,48,49,50,51].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“RMSE and correlation coefficients varied respectively from 0.4 to 18.8° and 0.33 to 0.99 [29,37,41,43,53,54,55,57,59,62,63].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“RMSE and coefficient correlation varied respectively from 1 to 11.5° and 0.4 to 1.00 [5,30,37,41,43,48,50,53,54,55,57,58,59,60,61].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“Also, as demonstrated by Robert-Lachaine et al. [37], the choice of the biomechanical model used to convert M/IMU orientation data into anatomically meaningful information will also influence validity differently depending on the joint studied.”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“According to Robert-Lachaine et al., shoulder rotation is also more influenced by the biomechanical model than shoulder flexion–extension or abduction/adduction.”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“Their results showed that biomechanical models used for the upper limbs are more likely to add variability, leading to larger RMSE.”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917
Wu, G., van der Helm, F. C. T., Veeger, H. E. J., Makhsous, M., Roy, P. V., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K. J., Wang, X., et al. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,569
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., DʼLima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,249
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
(2009) · Cited by 701
(1998) · Choice Reviews Online · doi:10.5860/choice.35-6297 · Cited by 430
New least squares solutions for estimating the average centre of rotation and the axis of rotation
Gamage, S. S. H. U., & Lasenby, J. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00160-9 · Cited by 378
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369
Harrington, M., Zavatsky, A. B., LAWSON, S. E. M., Yuan, Z., & Theologis, T. N. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.003 · Cited by 367
Cited by
Sorted by citations
Items 201–300 of 334
Blanco-Coloma, L., García-González, L., Sinovas-Alonso, I., Torio-Álvarez, S., Martos-Hernández, P., González-Expósito, S., Gil-Agudo, A. M., & Herrera-Valenzuela, D. S. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1449698 · Cited by 6
A Novel Measurement Procedure for Error Correction in Single Camera Gait Analysis
Galasso, S., Carissimo, C., Cerro, G., Molinara, M., Ferrigno, L., Calabrò, R. S., & Nunzio, A. M. D. (2024) · IEEE Access · doi:10.1109/access.2024.3485204 · Cited by 6
A Comparative Analysis of IMUs and Optical Systems in Layup Shot Biomechanics
Alkhalaf, N., Pain, M. T. G., & Hiley, M. J. (2025) · Applied Sciences · doi:10.3390/app15073847 · Cited by 6
Kurpiers, N., Petrone, N., Supej, M., Wisser, A., Hansen, J., & Kersting, U. G. (2020) · Sensors · doi:10.3390/s20133805 · Cited by 6
Physical Activity and Ecological Means of Transport—Functional Assessment Methodology
Bęczkowska, S. A., Grabarek, I., Zysk, Z., & Gosek-Ferenc, K. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19159211 · Cited by 6
Neuromotor variability partially explains different endurance capacities of expert pianists
Goubault, É., Turner, C., Mailly, R., Begon, M., Maso, F. D., & Verdugo, F. (2023) · Scientific Reports · doi:10.1038/s41598-023-42408-3 · Cited by 6
Comparative evaluation of different spinal stability metrics
Eskandari, A. H., Ghezelbash, F., Shirazi-Adl, A., & Larivière, C. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111901 · Cited by 6
Towards User-Friendly Wearable Platforms for Monitoring Unconstrained Indoor and Outdoor Activities
Rezaei, A., Khoshnam, M., & Menon, C. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3004319 · Cited by 6
Characterization of a low-cost markerless system for 3D gait analysis
D’Antonio, E., Taborri, J., Palermo, E., Rossi, S., & Patanè, F. (2020) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea49120.2020.9137236 · Cited by 6
Simon, S., Meining, J., Laurendi, L., Berkefeld, T., Dully, J., Dindorf, C., & Fröhlich, M. (2025) · Bioengineering · doi:10.3390/bioengineering12040403 · Cited by 5
Cameron‐Whytock, H. A., Divall, H., Lewis, M., & Apps, C. (2025) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2025.112728 · Cited by 5
Clément, J., Croteau, F., Gagnon, M., & Cros, S. (2024) · Sports Biomechanics · doi:10.1080/14763141.2024.2331174 · Cited by 5
Bini, R. R., & Hume, P. A. (2020) · Human Movement · doi:10.5114/hm.2020.94197 · Cited by 6
Pressure-sensor-based Gait Analysis for Disabled People
Chen, Y., Wu, C.-M., Chen, P., See, A. R., & Chen, S.-C. (2022) · Sensors and Materials · doi:10.18494/sam3559 · Cited by 5
Kirking, B. (2022) · Gait & Posture · doi:10.1016/j.gaitpost.2022.11.020 · Cited by 5
Agreement between Inertia and Optical Based Motion Capture during the VU-Return-to-Play- Field-Test
Richter, C., Daniels, K., King, E. A., & Franklyn‐Miller, A. (2020) · Sensors · doi:10.3390/s20030831 · Cited by 5
Development of a Smart Hallway for Marker-Less Human Foot Tracking and Stride Analysis
Gutta, V., Fallavollita, P., Baddour, N., & Lemaire, E. D. (2021) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2021.3069353 · Cited by 5
Spallone, G., Mancini, L., Carnevale, A., Campi, S., Schena, E., d’Hooghe, P. P. R. N., Hirschmann, M. T., Papalia, R., & Longo, U. G. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1677244 · Cited by 4
IMU Calibration Effect on Lower Limbs Kinematics Against Optical Motion Capture in Post-Stroke Gait
Lallès, A. P., Moucheboeuf, G., Doat, E., Pillet, H., & Bonnet, X. (2024) · IRBM · doi:10.1016/j.irbm.2024.100873 · Cited by 4
Favata, A., Marzabal, A., Font-Llagunes, J. M., & Pàmies‐Vilà, R. (2025) · PLoS ONE · doi:10.1371/journal.pone.0334177 · Cited by 4
McFarland, T. C., Ryu, J., Haas, C. T., & Abdel-Rahman, E. M. (2023) · Journal of Construction Engineering and Management · doi:10.1061/jcemd4.coeng-13765 · Cited by 4
Development and Evaluation of a Hybrid Measurement System to Determine the Kinematics of the Wrist
Dellai, J., Gilles, M. A., Rémy, O., Claudon, L., & Dietrich, G. (2024) · Sensors · doi:10.3390/s24082543 · Cited by 4
Implementation of Ergonomics Evaluation Methods in a Multi-Objective Optimization Framework
Pascual, A. I., Högberg, D., Anna, S., Brolin, E., Francisco, G. R., Luque, E. P., & Lars, H. (2020) · Advances in transdisciplinary engineering · doi:10.3233/atde200044 · Cited by 4
Quantitative of Badminton Practice Based on Wireless Sensor Network
Huang, H., Zhang, Y., Pang, G., & Ye, A. (2021) · Wireless Communications and Mobile Computing · doi:10.1155/2021/4060686 · Cited by 4
Analysing short-track speed skating performance factors
Claudel, J., & Clément, J. (2025) · Sports Biomechanics · doi:10.1080/14763141.2025.2557400 · Cited by 3
Dual-Camera System for AI Markerless 3D Lower Limb Motion Analysis
Francia, C., Donno, L., Chiosso, S., Palotti, G., Tarabini, M., & Galli, M. (2025) · Lecture notes in computer science · doi:10.1007/978-3-031-97781-7_22 · Cited by 3
Stepanenko, N. P., & Дубко, А. Г. (2025) · International Science Journal of Engineering & Agriculture · doi:10.46299/j.isjea.20250406.06 · Cited by 3
Catalá-Vilaplana, I., Liu, T., Vienneau, J., Nigg, S., Pérez‐Soriano, P., & Martínez, A. E. (2023) · Journal of Sports Sciences · doi:10.1080/02640414.2024.2307774 · Cited by 3
Lin, Y., Price, K., Carmichael, D. S., Maniar, N., Hickey, J. T., Timmins, R. G., Heiderscheit, B. C., Blemker, S. S., & Opar, D. A. (2025) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003786 · Cited by 3
Storli, L., & Lorås, H. W. (2025) · Children · doi:10.3390/children12060796 · Cited by 3
Distraction From Smartphones Changed Pedestrians’ Walking Behaviors in Open Areas
Luo, Y. G., Grimaldi, N. S., Zheng, H., Giang, W. C. W., & Hu, B. (2022) · Motor Control · doi:10.1123/mc.2022-0023 · Cited by 3
Ruder, M. C., Masood, Z., & Kobsar, D. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111818 · Cited by 4
Impact of Marker-set and Joint Constraint on kinematic outcome in Patients with knee Osteoarthritis
Mancini, L., Carnevale, A., Spallone, G., Antonacci, C., Campi, S., Alessandro de, S. I. R. E., D'Hoghe, P., Massaroni, C., Papalia, R., Schena, E., et al. (2025) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot66048.2025.11121952 · Cited by 3
A Comparison of Sensor Placement for Estimating Trunk Postures in Manual Material Handling
Hischke, M., Arroyo, G., Reiser, R. F., & Rosecrance, J. C. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-96089-0_9 · Cited by 3
Methods of posture analysis for computer workers
Maheronnaghsh, S., Santos, J., & Vaz, M. A. P. (2018) · International Journal of Occupational and Environmental Safety · doi:10.24840/2184-0954_002.002_0005 · Cited by 3
Flexible Sensor-Based Biomechanical Evaluation of Passive Low-Back Exoskeleton Use in Lifting
Yin, W., Chen, Y., Reddy, C. P., Zheng, L., Mehta, R. K., & Zhang, X. (2022) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1071181322661203 · Cited by 3
Back loading estimation during team handling: Is the use of only motion data sufficient?
Muller, A., & Corbeil, P. (2020) · PLoS ONE · doi:10.1371/journal.pone.0244405 · Cited by 3
Development of a real time estimation method of L5S1 moments in occupational lifting
Peters, S. L. A., Tabasi, A., Kingma, I., van Dijk, W., & van Dieën, J. H. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2022.111417 · Cited by 3
Martínez-Zarzuela, M., González-Alonso, J., Antón-Rodríguez, M., Díaz-Pernas, F. J., Müller, H., & Simón-Martínez, C. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2303.16150 · Cited by 3
Salem, N., Baklouti, S., Kammoun, M. A., Rezgui, T., Hajej, Z., & Bennour, S. (2024) · IEEE International Conference on Industrial Engineering and Engineering Management (IEEM) · doi:10.1109/ieem62345.2024.10857008 · Cited by 2
Amirova, L. E., Keller, A., Singh, G., King, M., Parikh, P., Stepp, N., Ugiliweneza, B., Gerasimenko, Y., & Behrman, A. L. (2025) · Children · doi:10.3390/children12070817 · Cited by 2
Liu, K., Hirsch, S. M., Singh, P., Chan, T. C. Y., Burkhart, T. A., & Hutchison, M. G. (2025) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/17543371251348697 · Cited by 2
Real-Time Open Source Kinematic Estimation with Wearable IMUs
Xu, C., Tan, Y., Strout, Z., Liu, G., Zhu, K., & Shull, P. B. (2025) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr66766.2025.11063160 · Cited by 2
Loureiro, M., Camargos, J. C. V., Oliveira, W., Machado, F., Elías, A., de Mello, R. C., Junior, A. G. L., & Frizera, A. (2025) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2025.104446 · Cited by 2
Evaluation of Magnetometer-less Inertial Sensors for Static Spatial Orientation Estimation
Alonso, A. C., Carro, G. G., Alvarez, J. C., Álvarez, D., & López, A. M. (2025) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc62753.2025.11079213 · Cited by 3
Wearable SIMO Inductive Resonant Link for Posture Monitoring
Monti, G., Lezzi, D., & Tarricone, L. (2025) · Sensors · doi:10.3390/s25175478 · Cited by 2
Poli, L., Petrelli, A. C., Russo, L., Pepe, I., Fischetti, F., Cataldi, S., & Greco, G. (2025) · Applied Sciences · doi:10.3390/app152011140 · Cited by 2
Argunsah, H., Yalçın, B., Ergin, M. A., Çoruhlu, G., Yalçin, M. N., Patoğlu, V., & Güven, Z. (2025) · Sensors · doi:10.3390/s26010088 · Cited by 2
Xu, C. F., Tan, Y. H., Strout, Z., Liu, G., Zhu, K., Wang, H., & Shull, P. B. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3653477 · Cited by 2
Accuracy and Reliability of Single-Camera Measurements of Ankle Clonus and Quadriceps Hyperreflexia
Macon, K., Hoang, D., Elizondo, L., Kallus, K., Sulzer, J. S., & Manella, K. J. (2021) · Archives of Rehabilitation Research and Clinical Translation · doi:10.1016/j.arrct.2021.100153 · Cited by 2
Postural Assessment Criteria for Manual Material Handling
Ryu, J., McFarland, T. C., Haas, C. T., & Abdel-Rahman, E. M. (2024) · ASCE Construction Research Congress (CRC) · doi:10.1061/9780784485293.064 · Cited by 2
Gasvoda, H., Li, M., Pader, A., Altay, R., Cmager, N., Pandey, T., Tseng, T., & Araci, I. E. (2025) · Advanced Sensor Research · doi:10.1002/adsr.202400146 · Cited by 2
Development of Skeletal Muscle Model for Bridge-Style Movement Rehabilitation
Zhang, G., Wang, C., Liu, Q., Wei, J., Luo, C., Duan, L., Long, J., Zhang, X., & Wang, G. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2026/1/012061 · Cited by 2
Wireless Body Area Networks for Child Healthcare Monitoring: A Review
Aqeel-ur-Rehman, Abdullah, I., & Rehman, S. U. (2018) · IEEE International Multitopic Conference (INMIC) · doi:10.1109/inmic.2018.8595655 · Cited by 2
Ergonomic Workplace Design Using Motion Capture Technology
Herzog, N. V., & Buchmeister, B. (2023) · DAAAM international scientific book ... · doi:10.2507/daaam.scibook.2023.01 · Cited by 2
Healthy working in inclusive companies – a study protocol of the GAIN project
Holzgreve, F., Bredereck, B., Heim, C., Weber, B., Ellegast, R. P., Groneberg, D. A., Gaum, C., & Ohlendorf, D. (2023) · Journal of Occupational Medicine and Toxicology · doi:10.1186/s12995-023-00399-x · Cited by 2
JOINT ANGLE ESTIMATION DURING FAST CUTTING MANOEUVRES USING ARTIFICIAL NEURAL NETWORKS
Mundt, M., David, S., Koeppe, A., Bamer, F., Potthast, W., & Markert, B. A. (2019) · RWTH Publications (RWTH Aachen) · Cited by 2
Human Motion Recognition Based On Inertial Sensor
Xing, M., Wei, G., Cao, H., Yang, F., Nie, Y., & Liu, J. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/782/3/032099 · Cited by 2
Designing smart garments for rehabilitation
Wang, Q. (2018) · TU/e Research Portal · Cited by 2
Validation of Fuze IMU system for ergonomics assessmentsPreprint
Serra-Hsu, E., & Taboga, P. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.12.05.519202 · Cited by 2
A Sensor-Based Approach for Automatic and Objective Ergonomic Risk Indices Calculation
Ciccarelli, M., Papetti, A., & Germani, M. (2025) · Lecture notes in mechanical engineering · doi:10.1007/978-3-031-76594-0_20 · Cited by 1
Desmyttere, G., Ralandison, S., Dusfour, G., Moulis, L., Amico, M., Julia, M., Pers, Y., & Jørgensen, C. (2025) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2025.106555 · Cited by 1
Musso, M., Bai, S., & Oliveira, A. S. (2025) · Wearable Technologies · doi:10.1017/wtc.2025.10026 · Cited by 1
Fehringer, V., Maurer, C., Holzgreve, F., Ohlendorf, D., & Wanke, E. M. (2025) · Sensors · doi:10.3390/s26010070 · Cited by 1
Tian, R., Kong, F., Wang, C., Chen, T., Zhang, S., Ding, K., & Yu, Z. (2026) · Measurement · doi:10.1016/j.measurement.2026.120371 · Cited by 1
Elías, A., Loureiro, M., Machado, F. S. V., & Frizera, A. (2026) · Scientific Reports · doi:10.1038/s41598-026-37448-4 · Cited by 1
Uncertainty estimation in marker-based motion capture of the tennis serve
Ozan, S., Fourel, L., Touzard, P., Kulpa, R., & Martin, C. (2025) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2025.113119 · Cited by 1
Liu, J., Liu, X., Wang, Z., & Wu, X. (2026) · tm - Technisches Messen · doi:10.1515/teme-2025-0155 · Cited by 1
Wang, D., Yu, J., Chen, S., Yang, J., Jiang, W., Gong, Y., & Luo, C. (2026) · Sensors · doi:10.3390/s26123654 · Cited by 1
Body Motion Capture and Applications
Akman, Ç., & Sönmez, T. (2021) · Advances in computational intelligence and robotics book series · doi:10.4018/978-1-7998-7468-3.ch009 · Cited by 1
IMUAngle: Joint Angle Estimation with Inertial Sensors in Daily Activities
Uhlenberg, L., Gangaraju, S. H., & Amft, O. (2022) · ACM International Symposium on Wearable Computers (ISWC) · doi:10.1145/3544794.3558470 · Cited by 1
A Case Study in Upper Body Kinematics of an Elite Axe Thrower Using Sensor Technology
Evans, S., & Bini, R. R. (2023) · Research Directs in Strength and Performance · doi:10.53520/rdsp2023.10558 · Cited by 1
Initial Calibration Method of Human Upper Limb Frame in Inertial Motion Capture System
Zhang, Q., Wu, L., Li, Q., Sun, X., & Xu, G. (2023) · Chinese Control Conference (CCC) · doi:10.23919/ccc58697.2023.10240120 · Cited by 1
Aqueveque, P., Gutierrez, M., Retamal, G., Germany, E., Peña, G., Gómez, B., & Ortega-Bastidas, P. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340262 · Cited by 1
Prado, M., Oyama, S., & Giambini, H. (2024) · Journal of Applied Biomechanics · doi:10.1123/jab.2023-0202 · Cited by 1
Santos, J., Abreu, A., Fonseca, P., Carvalhais, C., Baptista, J. S., Santos, R. S., & Vaz, M. A. P. (2020) · International Journal of Occupational and Environmental Safety · doi:10.24840/2184-0954_004.002_0001 · Cited by 1
Biomechanical Factors Affecting Individuals’ Performance in Sprint Kayaking
Shin, C. (2020) · Lincoln Repository (University of Lincoln) · doi:10.24385/lincoln.24326374 · Cited by 1
Assessing quality of upper limb movements after stroke with prospects of wearable technologies
Schwarz, A. (2021) · doi:10.3990/1.9789036551632 · Cited by 1
Hage, R., Detrembleur, C., Dierick, F., Pitance, L., Jojczyk, L., Estievenart, W., & Buisseret, F. (2019) · doi:10.31224/osf.io/6n4ke · Cited by 1
Monitoring in Football and Field Hockey
Wilmes, E. (2023) · doi:10.5463/thesis.215 · Cited by 1
Markerless motion analysis in sports and exercise
Bini, R. R., Colyer, S., Moura, F. A., Santiago, P. R. P., & Vanicek, N. (2026) · Journal of Sports Sciences · doi:10.1080/02640414.2026.2661158 · Cited by 1
Garnett, R. F., Davis, G. A., Sesek, R. F., Gallagher, S., Schall, M. C., & Chen, H. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-94619-1_14
DrAntonio, E., Salvatori, S., Patanè, F., Marzegan, A., Bonora, G., Carpinella, I., Ferrarin, M., & Rossi, S. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438695
Kinematics of the equine axial skeleton during aqua-treadmill exercise
York, J. (2017) · NECTAR - Northampton Electronic Collection of Thesis and Research (University of Northampton)
Validation method for body-mounted sensor attachments
Schmidt, K., & Hochmann, D. (2020) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2020-2006
The Impact of Chair Type on Quality Sitting Behaviours in a Prolonged Sitting Exposure
Simone, M. S. (2020) · York University Digital Library (York University)
Using Fatigue Failure Principles to Assess MSD Risk
Gallagher, S., & Barbe, M. F. (2022) · Wiley eBooks · doi:10.1002/9781119640172.ch13
Upper limb orientation assessment as an articulated body chain
Rodríguez, L. A. C., Madrigal, J. A. B., Cardiel, E., & Hernández, P. R. (2022) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2022.103852
A Novel Algorithm for Automatic Estimation of Gait Parameters Using Lower-Body Kinematics
Aftab, Z., Ahmed, G., Hanif, M. A., & Shahzad, M. A. (2022) · IEEE Access · doi:10.1109/access.2022.3218011
مقارنة وصفیة لأنظمة مستشعرات القصور الذاتی كأداة للتصویر الحركی فی ریاضة الكاراتیه
فؤاد, أ. ص., العزیز, ع. ا. ح. ع., عبدالسلام, ا. ا., & الله, ع. ا. ز. ع. (2022) · المجلة العلمية للتربية البدنية وعلوم الرياضة · doi:10.21608/sjes.2022.262908
Zarzuela, M. M., González‐Ortega, D., Antón‐Rodríguez, M., Pernas, F. J. D., Müller, H., & Simón-Martínez, C. (2023) · Gait & Posture · doi:10.1016/j.gaitpost.2023.07.149
Sixty years in service to international biomedical engineering community
Magjarević, R. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02987-9
Advancing Back-Support Exoskeleton Control: A Biomechanical Approach
Tabasi, S. A. (2024) · doi:10.5463/thesis.612
Individual’s Mechanics, Movement and Kinematics Post-Stroke
(2024) · Frontiers research topics · doi:10.3389/978-2-8325-5027-4
Concurrent Validity of Embedded Solutions for Whole Body Dynamics Analysis
Sabbah, M., Watier, B., Dumas, R., Gautier, M., & Bonnet, V. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3485475
Fourniol, M., Vauché, R., Rao, G., Watelain, É., & Kussener, E. (2025) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea15020033
Gundersen, A. H., Larsen, S., & van den Tillaar, R. (2025) · Research Square · doi:10.21203/rs.3.rs-7056827/v1
Deep learning-based physical exercise assessment of older adults using single-camera videos
Stefanova, V., Maeyens, E., Brughmans, J., Vargemidis, D., Lebleu, J., Stulens, L., Broeder, S., Gilis, K., Deschodt, M., Vanwanseele, B., et al. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001576
Borno, M. A., O’Day, J. J., Ibarra, V., Dunne, J. J., Seth, A., Habib, A., Ong, C. F., Hicks, J. L., Uhlrich, S. D., & Delp, S. L. (2022) · Figshare · doi:10.6084/m9.figshare.19205886
Metadata
- Authors
- Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A.
- Affiliations
- Institut de recherche Robert-Sauvé en santé et en sécurité du travail (CA)
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2016-07-05
- Volume
- 55
- Issue
- 4
- Pages
- 609-619
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2460830751
- Cited by
- 329
- References
- 36
- Citations by year
- 2026: 27 · 2025: 39 · 2024: 29 · 2023: 35 · 2022: 42 · 2021: 46 · 2020: 43 · 2019: 29 · 2018: 23 · 2017: 16
- FWCI
- 35.71
- Type
- journal article
- Language
- en
- Open access
- green
- pharesst.irsst.qc.ca
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- PhareSST (submittedVersion)
- Funders
- IRSST (2012-0040, Postdoctoral program)
- Topics
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- inertial measurement unit, optical motion capture, whole-body kinematics, technological errors, joint angles, task complexity, task duration, manual material handling, functional movement, local coordinate system, anatomical landmarks, Xsens, human factors, worker tracking
- MeSH terms
- Adult, Biomechanical Phenomena, Female, Humans, Male, Models, Theoretical, Monitoring, Physiologic, Motion, Movement, Posture, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review