The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis
Open accessAbstract
The potential of inertial measurement units (IMUs) for ergonomics applications appears promising. However, previous IMUs validation studies have been incomplete regarding aspects of joints analysed, complexity of movements and duration of trials. The objective was to determine the technological error and biomechanical model differences between IMUs and an optoelectronic system and evaluate the effect of task complexity and duration. Whole-body kinematics from 12 participants was recorded simultaneously with a full-body Xsens system where an Optotrak cluster was fixed on every IMU. Short functional movements and long manual material handling tasks were performed and joint angles were compared between the two systems. The differences attributed to the biomechanical model showed significantly greater (P ≤ .001) RMSE than the technological error. RMSE was systematically higher (P ≤ .001) for the long complex task with a mean on all joints of 2.8° compared to 1.2° during short functional movements. Definition of local coordinate systems based on anatomical landmarks or single posture was the most influent difference between the two systems. Additionally, IMUs accuracy was affected by the complexity and duration of the tasks. Nevertheless, technological error remained under 5° RMSE during handling tasks, which shows potential to track workers during their daily labour.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“RMSE results varied between less than 1° and 9°, showing good joint measurement validity [33,34,37,40,41].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“RMSE and correlation coefficients varied respectively from 0.2 to 9.3° and 0.53 to 1.00, showing fair to excellent validity [5,30,37,41,42,46,53,54,55,56,57,58,59].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“Validity was similar across all movement planes and axes [34,36,37,38,41,46,47,48,49,50,51].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“RMSE and correlation coefficients varied respectively from 0.4 to 18.8° and 0.33 to 0.99 [29,37,41,43,53,54,55,57,59,62,63].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“RMSE and coefficient correlation varied respectively from 1 to 11.5° and 0.4 to 1.00 [5,30,37,41,43,48,50,53,54,55,57,58,59,60,61].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“Also, as demonstrated by Robert-Lachaine et al. [37], the choice of the biomechanical model used to convert M/IMU orientation data into anatomically meaningful information will also influence validity differently depending on the joint studied.”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“According to Robert-Lachaine et al., shoulder rotation is also more influenced by the biomechanical model than shoulder flexion–extension or abduction/adduction.”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
In the citing paper
“Their results showed that biomechanical models used for the upper limbs are more likely to add variability, leading to larger RMSE.”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917
Wu, G., van der Helm, F. C. T., Veeger, H. E. J., Makhsous, M., Roy, P. V., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K. J., Wang, X., et al. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,569
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., DʼLima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,249
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
(2009) · Cited by 701
(1998) · Choice Reviews Online · doi:10.5860/choice.35-6297 · Cited by 430
New least squares solutions for estimating the average centre of rotation and the axis of rotation
Gamage, S. S. H. U., & Lasenby, J. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00160-9 · Cited by 378
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369
Harrington, M., Zavatsky, A. B., LAWSON, S. E. M., Yuan, Z., & Theologis, T. N. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.003 · Cited by 367
Cited by
Sorted by citations
Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion
Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., & Stricker, D. (2017) · Sensors · doi:10.3390/s17061257 · Cited by 361
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., & Davies, J. (2018) · Sensors · doi:10.3390/s18030719 · Cited by 318
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309
Sensing of joint and spinal bending or stretching via a retractable and wearable badge reel
Li, C., Liu, D., Xu, C., Wang, Z., Shu, S., Sun, Z., Wang, Z. L., & Wang, Z. L. (2021) · Nature Communications · doi:10.1038/s41467-021-23207-8 · Cited by 230
Schall, M. C., Sesek, R. F., & Cavuoto, L. A. (2018) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720817753907 · Cited by 205
Ergonomic postural assessment using a new open-source human pose estimation technology (OpenPose)
Kim, W., Sung, J., Saakes, D. P., Huang, C., & Xiong, S. (2021) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2021.103164 · Cited by 192
Sport Biomechanics Applications Using Inertial, Force, and EMG Sensors: A Literature Overview
Taborri, J., Keogh, J., Kos, A., Santuz, A., Umek, A., Urbanczyk, C. A., van der Kruk, E., & Rossi, S. (2020) · Applied Bionics and Biomechanics · doi:10.1155/2020/2041549 · Cited by 175
Borno, M. A., O’Day, J. J., Ibarra, V., Dunne, J. J., Seth, A., Habib, A., Ong, C. F., Hicks, J. L., Uhlrich, S. D., & Delp, S. L. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01001-x · Cited by 155
Prediction of lower limb joint angles and moments during gait using artificial neural networks
Mundt, M., Thomsen, W., Witter, T., Koeppe, A., David, S., Bamer, F., Potthast, W., & Markert, B. A. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02061-3 · Cited by 140
Use of wearable sensor technology in gait, balance, and range of motion analysis
Díaz, S., Stephenson, J. B., & Labrador, M. A. (2019) · Applied Sciences · doi:10.3390/app10010234 · Cited by 132
Towards Inertial Sensor Based Mobile Gait Analysis: Event-Detection and Spatio-Temporal Parameters
Teufl, W., Lorenz, M., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2018) · Sensors · doi:10.3390/s19010038 · Cited by 138
Teufl, W., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2019) · PLOS ONE · doi:10.1371/journal.pone.0213064 · Cited by 129
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123
Blair, S., Duthie, G., Robertson, S., Hopkins, W., & Ball, K. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.03.031 · Cited by 117
A narrative review on contemporary and emerging uses of inertial sensing in occupational ergonomics
Lim, S. I., & D’Souza, C. (2020) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2020.102937 · Cited by 125
Robert‐Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.02.029 · Cited by 108
Self-citationTeufl, W., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2018) · Sensors · doi:10.3390/s18071980 · Cited by 111
Lind, C. M., Abtahi, F., & Forsman, M. (2023) · Sensors · doi:10.3390/s23094259 · Cited by 116
Milosevic, B., Leardini, A., & Farella, E. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-00762-7 · Cited by 103
Validation of a 3D Markerless System for Gait Analysis Based on OpenPose and Two RGB Webcams
D’Antonio, E., Taborri, J., Mileti, I., Rossi, S., & Patanè, F. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3081188 · Cited by 103
Determining anatomical frames via inertial motion capture: A survey of methods
Vitali, R. V., & Perkins, N. C. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109832 · Cited by 109
Validation of an IMU Suit for Military-Based Tasks
Mavor, M. P., Ross, G. B., Clouthier, A. L., Karakolis, T., & Graham, R. B. (2020) · Sensors · doi:10.3390/s20154280 · Cited by 92
Paolo, S. D., Lopomo, N. F., Villa, F. D., Paolini, G., Figari, G., Bragonzoni, L., Grassi, A., & Zaffagnini, S. (2021) · Sensors · doi:10.3390/s21072331 · Cited by 91
Teufl, W., Taetz, B., Miezal, M., Lorenz, M., Pietschmann, J., Jöllenbeck, T., Fröhlich, M., & Bleser, G. (2019) · Sensors · doi:10.3390/s19225006 · Cited by 87
Return to sports after ACL injury 5 years from now: 10 things we must do
Gokeler, A., Grassi, A., Hoogeslag, R. A. G., van Houten, A. H., Lehman, T., Bolling, C. S., Buckthorpe, M. W., Norte, G. E., Benjaminse, A., Heuvelmans, P., et al. (2022) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-022-00514-7 · Cited by 79
Effect of local magnetic field disturbances on inertial measurement units accuracy
Robert‐Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.04.011 · Cited by 77
Self-citationValidity of the Perception Neuron inertial motion capture system for upper body motion analysis
Sers, R., Forrester, S., Moss, E. L., Ward, S., Ma, J., & Zecca, M. (2019) · Measurement · doi:10.1016/j.measurement.2019.107024 · Cited by 78
Conversion of Upper-Limb Inertial Measurement Unit Data to Joint Angles: A Systematic Review
Fang, Z., Woodford, S. C., Senanayake, D., & Ackland, D. C. (2023) · Sensors · doi:10.3390/s23146535 · Cited by 76
Rapp, E., Shin, S., Thomsen, W., Ferber, R., & Halilaj, E. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110229 · Cited by 80
Held, J. P. O., Klaassen, B., Eenhoorn, A., van Beijnum, B.-J. F., Buurke, J. H., Veltink, P. H., & Luft, A. R. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00027 · Cited by 69
Validation of a low-cost inertial motion capture system for whole-body motion analysis
Robert‐Lachaine, X., Mecheri, H., Muller, A., Larue, C., & Plamondon, A. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.109520 · Cited by 69
Self-citationLebel, K., Boissy, P., Nguyen, H., & Duval, C. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0347-6 · Cited by 65
Poitras, I., Bielmann, M., Campeau‐Lecours, A., Mercier, C., Bouyer, L. J., & Roy, J. (2019) · Sensors · doi:10.3390/s19081885 · Cited by 65
In-field instrumented ergonomic risk assessment: Inertial measurement units versus Kinect V2
Humadi, A., Nazarahari, M., Ahmad, R., & Rouhani, H. (2021) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2021.103147 · Cited by 60
Cudejko, T., Button, K., & Al-Amri, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-18845-x · Cited by 64
Paolo, S. D., Nijmeijer, E. M., Bragonzoni, L., Dingshoff, E., Gokeler, A., & Benjaminse, A. (2022) · European Journal of Sport Science · doi:10.1080/17461391.2022.2064771 · Cited by 58
Hindle, B. R., Keogh, J., & Lorimer, A. V. (2021) · Applied Bionics and Biomechanics · doi:10.1155/2021/6628320 · Cited by 63
Maurer, C., Holzgreve, F., Fraeulin, L., Betz, W., Erbe, C., Brueggmann, D., Wanke, E. M., Nienhaus, A., Groneberg, D. A., & Ohlendorf, D. (2021) · Sensors · doi:10.3390/s21124077 · Cited by 57
Yamamoto, M., Shimatani, K., Hasegawa, M., Kurita, Y., Ishige, Y., & Takemura, H. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3135879 · Cited by 58
Validation of the Perception Neuron system for full-body motion capture
Choo, C. Z. Y., Chow, J. Y., & Komar, J. (2022) · PLoS ONE · doi:10.1371/journal.pone.0262730 · Cited by 61
Semi-Automatic Sensor-to-Body Calibration of Inertial Sensors on Lower Limb Using Gait Recording
Nazarahari, M., & Rouhani, H. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2939981 · Cited by 57
Noninvasive spinal stimulation safely enables upright posture in children with spinal cord injury
Keller, A., Singh, G., Sommerfeld, J. H., King, M., Parikh, P., Ugiliweneza, B., D’Amico, J. M., Gerasimenko, Y., & Behrman, A. L. (2021) · Nature Communications · doi:10.1038/s41467-021-26026-z · Cited by 56
Accuracy and Acceptability of Wearable Motion Tracking for Inpatient Monitoring Using Smartwatches
Auepanwiriyakul, C., Waibel, S., Songa, J., Bentley, P., & Faisal, A. A. (2020) · Sensors · doi:10.3390/s20247313 · Cited by 56
Tavassolian, M., Cuthbert, T. J., Napier, C., Peng, J., & Menon, C. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.201900165 · Cited by 57
van der Straaten, R., Baets, L. D., Jonkers, I., & Timmermans, A. A. A. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.10.005 · Cited by 54
Brouwer, N. P., Yeung, T., Bobbert, M. F., & Besier, T. F. (2020) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13851 · Cited by 51
A “Smart” Undershirt for Tracking Upper Body Motions: Task Classification and Angle Estimation
Esfahani, M. I. M., & Nussbaum, M. A. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2859626 · Cited by 50
Brandt, M., Madeleine, P., Samani, A., Ajslev, J. Z. N., Jakobsen, M. D., Sundstrup, E., & Andersen, L. L. (2018) · Journal of Medical Internet Research · doi:10.2196/10272 · Cited by 50
Humadi, A., Nazarahari, M., Ahmad, R., & Rouhani, H. (2020) · IEEE Access · doi:10.1109/access.2020.3048645 · Cited by 48
Doğan, M., Koçak, M., Kılınç, Ö. O., Ayvat, F., Sütçü, G., Ayvat, E., Kılınç, M., Ünver, Ö., & Yıldırım, S. A. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.02.024 · Cited by 54
Accuracy of Base of Support Using an Inertial Sensor Based Motion Capture System
Guo, L., & Xiong, S. (2017) · Sensors · doi:10.3390/s17092091 · Cited by 46
Reliability of Xsens IMU-Based Lower Extremity Joint Angles during In-Field Running
Debertin, D., Wargel, A., & Mohr, M. (2024) · Sensors · doi:10.3390/s24030871 · Cited by 47
A survey of human shoulder functional kinematic representations
Krishnan, R., Björsell, N., Gutierrez-Farewik, E. M., & Smith, C. (2018) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-018-1903-3 · Cited by 45
Assessment of the measurement accuracy of inertial sensors during different tasks of daily living
Mundt, M., Thomsen, W., David, S., Dupré, T., Bamer, F., Potthast, W., & Markert, B. A. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.12.023 · Cited by 45
Wearable Sensor Network for Biomechanical Overload Assessment in Manual Material Handling
Giannini, P., Bassani, G., Avizzano, C. A., & Filippeschi, A. (2020) · Sensors · doi:10.3390/s20143877 · Cited by 45
Measures of Interjoint Coordination Post-stroke Across Different Upper Limb Movement Tasks
Schwarz, A., Veerbeek, J. M., Held, J. P. O., Buurke, J. H., & Luft, A. R. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.620805 · Cited by 47
Shuai, Z., Dong, A., Liu, H., & Cui, Y. (2022) · Sensors · doi:10.3390/s22030863 · Cited by 46
Influence of BMI on Gait Characteristics of Young Adults: 3D Evaluation Using Inertial Sensors
Rosso, V., Agostini, V., Takeda, R., TADANO, S., & Gastaldi, L. (2019) · Sensors · doi:10.3390/s19194221 · Cited by 43
Health and productivity impact of semi-automated work systems in construction
Ryu, J., McFarland, T. C., Banting, B. R., Haas, C. T., & Abdel-Rahman, E. M. (2020) · Automation in Construction · doi:10.1016/j.autcon.2020.103396 · Cited by 43
IMU-Based Systems for Upper-Limb Kinematic Analysis in Clinical Applications: A Systematic Review
Favata, A., Gallart-Agut, R., Pàmies‐Vilà, R., Carme Torras, A., & Font-Llagunes, J. M. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3436532 · Cited by 42
Accuracy of angular displacements and velocities from inertial-based inclinometers
Chen, H., Schall, M. C., & Fethke, N. B. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.09.007 · Cited by 41
Bessone, V., Höschele, N., Schwirtz, A., & Seiberl, W. (2019) · Sports Biomechanics · doi:10.1080/14763141.2019.1671486 · Cited by 47
Chen, H., Schall, M. C., & Fethke, N. B. (2020) · Applied Ergonomics · doi:10.1016/j.apergo.2020.103187 · Cited by 38
Validity of inertial measurement units for tracking human motion: a systematic review
Ghattas, J., & Jarvis, D. N. (2021) · Sports Biomechanics · doi:10.1080/14763141.2021.1990383 · Cited by 37
Cerfoglio, S., Capodaglio, P., Rossi, P., Conforti, I., D’Angeli, V., Milani, E., Galli, M., & Cimolin, V. (2023) · Sensors · doi:10.3390/s23136156 · Cited by 38
Muller, A., Pontonnier, C., Robert‐Lachaine, X., Dumont, G., & Plamondon, A. (2019) · Applied Ergonomics · doi:10.1016/j.apergo.2019.102935 · Cited by 37
Self-citationValidity and reliability of inertial sensors for elbow and wrist range of motion assessment
Costa, V., Ramírez, O. E. M., Otero, A., Muñoz‐García, D., Uribarri, S., & Raya, R. (2020) · PeerJ · doi:10.7717/peerj.9687 · Cited by 37
Zabat, M., Ababou, A., Ababou, N., & Dumas, R. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02033-7 · Cited by 36
Robert‐Lachaine, X., Parent, G., Fuentes, A., Hagemeister, N., & Aïssaoui, R. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.01.029 · Cited by 36
Self-citationAnalysis of the Limits of Automated Rule-Based Ergonomic Assessment in Bricklaying
Ryu, J., Diraneyya, M. M., Haas, C. T., & Abdel-Rahman, E. M. (2020) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001978 · Cited by 35
Hubaut, R., Guichard, R., Greenfield, J., & Blandeau, M. (2022) · Sensors · doi:10.3390/s22020436 · Cited by 35
Koopman, A. S., Kingma, I., Faber, G. S., Bornmann, J., & van Dieën, J. H. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.10.001 · Cited by 34
Concurrent validity of an inertial measurement system in tennis forehand drive
Pedro, B., Cabral, S., & Veloso, A. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110410 · Cited by 34
Warmerdam, E., Romijnders, R., Geritz, J., Elshehabi, M., Maetzler, C., Otto, J. C., Reimer, M., Stürner, K. H., Baron, R., Paschen, S., et al. (2021) · Sensors · doi:10.3390/s21175833 · Cited by 39
Accuracy of identification of low or high risk lifting during standardised lifting situations
Brandt, M., Madeleine, P., Samani, A., Jakobsen, M. D., Skals, S., Vinstrup, J., & Andersen, L. L. (2017) · Ergonomics · doi:10.1080/00140139.2017.1408857 · Cited by 34
Comparative Analysis of Markerless Motion Capture Systems for Measuring Human Kinematics
Ceriola, L., Taborri, J., Donati, M., Rossi, S., Patanè, F., & Mileti, I. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3431873 · Cited by 33
Cuadrado, J., Michaud, F., Lugrís, U., & Soto, M. P. (2021) · Sensors · doi:10.3390/s21020427 · Cited by 33
Fraeulin, L., Holzgreve, F., Brinkbäumer, M., Dziuba, A., Friebe, D., Klemz, S., Schmitt, M., Anna-Lena Theis, A., Tenberg, S., van Mark, A., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0243646 · Cited by 36
Wagner, J. F. (2018) · Gyroscopy and Navigation · doi:10.1134/s2075108718010091 · Cited by 32
Fleron, M. K., Ubbesen, N. C. H., Battistella, F., Dejtiar, D. L., & Oliveira, A. S. (2018) · Sports Biomechanics · doi:10.1080/14763141.2017.1409259 · Cited by 31
Rezaei, A., Cuthbert, T. J., Gholami, M., & Menon, C. (2019) · Sensors · doi:10.3390/s19194288 · Cited by 31
Cerfoglio, S., Galli, M., Tarabini, M., Bertozzi, F., Sforza, C., & Zago, M. (2021) · Sensors · doi:10.3390/s21227709 · Cited by 32
Adamowicz, L., Gurchiek, R. D., Ferri, J., Ursiny, A. T., Fiorentino, N. M., & McGinnis, R. S. (2019) · Sensors · doi:10.3390/s19235143 · Cited by 30
Motor Control Training for the Shoulder with Smart Garments
Wang, Q., Baets, L. D., Timmermans, A. A. A., Chen, W., Giacolini, L., Matheve, T., & Markopoulos, P. (2017) · Sensors · doi:10.3390/s17071687 · Cited by 30
Meng, L., Martínez-Hernández, U., Childs, C. R., Dehghani-Sanij, A. A., & Buis, A. W. P. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2938764 · Cited by 29
Guignard, B., Ayad, O., Baillet, H., Mell, F., Escobar, D. S., Boulanger, J., & Seifert, L. (2021) · Sports Biomechanics · doi:10.1080/14763141.2021.1945136 · Cited by 29
Changes in body position on the bike during seated sprint cycling: Applications to bike fitting
Bini, R. R., Daly, L., & Kingsley, M. (2019) · European Journal of Sport Science · doi:10.1080/17461391.2019.1610075 · Cited by 28
Does fatigue affect the kinematics of shooting in female basketball?
Li, F., Li, Z., Borović, I., Rupčić, T., & Knjaz, D. (2021) · International Journal of Performance Analysis in Sport · doi:10.1080/24748668.2021.1945878 · Cited by 27
Forces: A Motion Capture-Based Ergonomic Method for the Today’s World
Marín, J., & Marín, J. J. (2021) · Sensors · doi:10.3390/s21155139 · Cited by 27
McCabe, M. V., Citters, D. W. V., & Chapman, R. M. (2022) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2022.2044028 · Cited by 27
Wearable inertial sensors for objective kinematic assessments: A brief overview
Schall, M. C., Chen, H., & Cavuoto, L. A. (2022) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2022.2100407 · Cited by 27
Bae, K., Lee, S., Bak, S.-Y., Kim, H. S., Ha, Y., & You, J. H. (2024) · Scientific Reports · doi:10.1038/s41598-024-79707-2 · Cited by 26
Weitbrecht, M., Holzgreve, F., Fraeulin, L., Haenel, J., Betz, W., Erbe, C., Maurer, C., Wanke, E. M., Brueggmann, D., Nienhaus, A., et al. (2022) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/00187208211053073 · Cited by 26
Ghaffari, A., Rahbek, O., Lauritsen, R. E. K., Kappel, A., Kold, S., & Rasmussen, J. (2022) · Sensors · doi:10.3390/s22145289 · Cited by 27
Hughes, C. M. L., Louie, A., Sun, S., Gordon-Murer, C., Belay, G. J., Baye, M., & Zhang, X. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00322 · Cited by 25
Kim, D., Jin, Y., Cho, H., Jones, T., Zhou, Y. M., Fadaie, A., Popov, D., Swaminathan, K., & Walsh, C. J. (2025) · Nature Communications · doi:10.1038/s41467-025-58624-6 · Cited by 24
Giraldo-Pedroza, A., Lee, W. C. C., Lam, W., Coman, R. L., & Alıcı, G. (2020) · Sensors · doi:10.3390/s20226637 · Cited by 24
Quantification of Error Sources with Inertial Measurement Units in Sports
Kamstra, H., Wilmes, E., & van der Helm, F. C. T. (2022) · Sensors · doi:10.3390/s22249765 · Cited by 26
A passive upper-limb exoskeleton reduced muscular loading during augmented reality interactions
Kong, Y., Park, S., Shim, J.-W., Choi, K., Shim, H.-H., Kia, K., & Kim, J. H. (2023) · Applied Ergonomics · doi:10.1016/j.apergo.2023.103982 · Cited by 24
Motion-Based Prediction of Hands and Feet Contact Efforts During Asymmetric Handling Tasks
Muller, A., Pontonnier, C., & Dumont, G. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2913308 · Cited by 24
Metadata
- Authors
- Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A.
- Affiliations
- Institut de recherche Robert-Sauvé en santé et en sécurité du travail (CA)
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2016-07-05
- Volume
- 55
- Issue
- 4
- Pages
- 609-619
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2460830751
- Cited by
- 329
- References
- 36
- Citations by year
- 2026: 27 · 2025: 39 · 2024: 29 · 2023: 35 · 2022: 42 · 2021: 46 · 2020: 43 · 2019: 29 · 2018: 23 · 2017: 16
- FWCI
- 35.71
- Type
- journal article
- Language
- en
- Open access
- green
- pharesst.irsst.qc.ca
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- PhareSST (submittedVersion)
- Funders
- IRSST (2012-0040, Postdoctoral program)
- Topics
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- inertial measurement unit, optical motion capture, whole-body kinematics, technological errors, joint angles, task complexity, task duration, manual material handling, functional movement, local coordinate system, anatomical landmarks, Xsens, human factors, worker tracking
- MeSH terms
- Adult, Biomechanical Phenomena, Female, Humans, Male, Models, Theoretical, Monitoring, Physiologic, Motion, Movement, Posture, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review