Collagen Tube Conduits in Peripheral Nerve Repair: A Retrospective Analysis
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
A chart review was conducted of all patients receiving NeuraGen® conduits from 2002 to 2007 at Regions Hospital, a level I trauma center. Ninety-six patients underwent 126 repairs using NeuraGen® conduits, and 64 patients were seen in follow-up. Repairs were largely of upper extremity sensory nerves but six were repairs of nerves elsewhere in the body. There were no intra-operative complications, but there were two minor postoperative complications and one postoperative pulmonary embolus. Forty of 126 repairs were lost to follow-up. Twenty-six of 126 repairs had follow-up with quantitative testing of nerve recovery (2-point discrimination, Semmes—Weinstein, or EMG testing), with 35% reporting improvement and 31% going on to a revision operation. Sixty of 126 repairs had qualitative testing performed (subjective or objective reporting of sensation or motor function), with 45% reporting improvement and 5% going on to a revision operation. Patients who went on to revision surgery were more likely to have undergone quantitative evaluation of sensation. Overall, sensory recovery was in the 35–45% range in our experience. Our results indicate that NeuraGen® collagen conduits can be used safely throughout the body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weber, R. A., Breidenbach, W. C., Brown, R. E., Jabaley, M. E., & Mass, D. P. (2000) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200010000-00013 · Cited by 552 · cited 1×
“A multicenter study of 136 nerve repairs suggested that PGA conduits are at least as effective as nerve grafting for repairing avulsed nerves, with 44% having excellent results, 30% having good results, and 26% having poor results [12].”
BackgroundClinical Nerve Reconstruction with a Bioabsorbable Polyglycolic Acid Tube
Mackinnon, S. E., & Dellon, A. L. (1990) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199003000-00015 · Cited by 535 · cited 1×
“A number of studies suggest that bioabsorbable nerve conduits are at least as effective as nerve grafting for repair of short nerve defects, without the morbidity associated with graft harvest [2, 3, 10–12].”
BackgroundMonkey median nerve repaired by nerve graft or collagen nerve guide tube
Archibald, S., Shefner, J., Krarup, C., & Madison, R. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-05-04109.1995 · Cited by 359 · cited 1×
“Nerve conduits made of collagen have been shown to be effective in rat and monkey models of nerve repair and are FDA-approved for use in humans [1, 5, 7].”
BackgroundBattiston, B., Geuna, S., Ferrero, M., & Tos, P. (2005) · Microsurgery · doi:10.1002/micr.20127 · Cited by 346 · cited 1×
“Another study comparing PGA conduits to muscle–vein grafts found no difference between the two techniques [2].”
ResultSynthetic Nerve Guide Implants in Humans: A Comprehensive Survey
Schlosshauer, B., Dreesmann, L., Schaller, H.-E., & Sinis, N. (2006) · Neurosurgery · doi:10.1227/01.neu.0000235197.36789.42 · Cited by 245 · cited 1×
“A number of studies suggest that bioabsorbable nerve conduits are at least as effective as nerve grafting for repair of short nerve defects, without the morbidity associated with graft harvest [2, 3, 10–12].”
BackgroundBertleff, M. J. O. E., Meek, M. F., & Nicolai, J.-P. A. (2005) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.12.009 · Cited by 233 · cited 1×
“Finally, a randomized, controlled study of 30 patients with nerves repaired using a PLCL tube or a nerve graft found similar success with either technique [3].”
ResultKrarup, C., Archibald, S. J., & Madison, R. D. (2002) · Annals of Neurology · doi:10.1002/ana.10054 · Cited by 172 · cited 1×
“Nerve conduits made of collagen have been shown to be effective in rat and monkey models of nerve repair and are FDA-approved for use in humans [1, 5, 7].”
BackgroundEarly Clinical Experience With Collagen Nerve Tubes in Digital Nerve Repair
Bushnell, B. D., McWilliams, A. D., Whitener, G. B., & Messer, T. M. (2008) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2008.03.015 · Cited by 167 · cited 1×
“Our study had several differences when compared with previous, smaller studies with collagen conduits [4, 6, 8, 9].”
ResultChamberlain, L. J., Yannas, I. V., Hsu, H.-P., Strichartz, G. R., & Spector, M. (2000) · Journal of Neuroscience Research · doi:10.1002/(sici)1097-4547(20000601)60:5<666::aid-jnr12>3.0.co;2-0 · Cited by 159
Lohmeyer, J., Siemers, F., Machens, H.-G., & Mailänder, P. (2009) · Journal of Reconstructive Microsurgery · doi:10.1055/s-0028-1103505 · Cited by 152 · cited 2×
“Finally, a small prospective study of digital nerve repair with collagen conduits found good or excellent nerve recovery in nine out of 12 patients [9].”
BackgroundResultFarole, A., & Jamal, B. T. (2008) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2008.06.017 · Cited by 107 · cited 2×
“Another study employed collagen conduits in repair of nine lingual and inferior alveolar nerve injuries, and on evaluation of touch, pinprick, and thermal sensation, they found good improvement in four, some improvement in four, and no improvement in one [6].”
BackgroundResult
Cited by
Kehoe, S., Zhang, X. F., & Boyd, D. (2012) · Injury · doi:10.1016/j.injury.2010.12.030 · Cited by 725
Repairing injured peripheral nerves: Bridging the gap
Deumens, R., Bozkurt, A., Meek, M. F., Marcus, M. A. E., Joosten, E. A. J., Weis, J., & Brook, G. A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.10.002 · Cited by 510
Current and Novel Polymeric Biomaterials for Neural Tissue Engineering
Boni, R., Ali, A., Shavandi, A., & Clarkson, A. N. (2018) · Journal of Biomedical Science · doi:10.1186/s12929-018-0491-8 · Cited by 439
Brooks, D. N., Weber, R. V., Chao, J. D., Rinker, B. D., Zoldos, J., Robichaux, M. R., Ruggeri, S. B., Anderson, K. A., Bonatz, E. E., Wisotsky, S. M., et al. (2012) · Microsurgery · doi:10.1002/micr.20975 · Cited by 329
Nerve grafting for peripheral nerve injuries with extended defect sizes
Kornfeld, T., Vogt, P. M., & Radtke, C. (2019) · Wiener Medizinische Wochenschrift · doi:10.1007/s10354-018-0675-6 · Cited by 237
Metadata
- Authors
- Wangensteen, K. J., & Kalliainen, L. K.
- Venue
- HAND
- Publisher
- SAGE Publications
- Published
- 2009-11-24
- Volume
- 5
- Issue
- 3
- Pages
- 273-277
- ISSN
- 1558-9447 (ISSN-L)
- 1558-9455
- OpenAlex
- W2142478822
- Cited by
- 161
- References
- 11
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.