2010 Mid-America Orthopaedic Association Physician in Training Award: Healing Complications Are Common After Locked Plating for Distal Femur Fractures
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Several mechanical studies suggest locking plate constructs may inhibit callus necessary for healing of distal femur fractures. However, the rate of nonunion and factors associated with nonunion are not well established. QUESTIONS/PURPOSES: We (1) determined the healing rate of distal femur fractures treated with locking plates, (2) assessed the effect of patient injury and treatment variables on fracture healing, and (3) compared callus formation in fractures that healed with those that did not heal. PATIENTS AND METHODS: We retrospectively reviewed 82 patients treated with 86 distal femur fractures using lateral locking plates. We reviewed all charts and radiographs to determine patient and treatment variables and then determined the effects of these variables on healing. We quantitatively measured callus at 6, 12, and 24 weeks. The minimum time for telephone interviews and SF-36v2(TM) scores was 1 year (mean, 4.2 years; range, 1-7.2 years). RESULTS: Fourteen fractures (20%) failed to unite. Demographics and comorbidities were similar in patients who achieved healing compared with those who had nonunions. There were more empty holes in the plate adjacent to fractures that healed; comminuted fractures failed to heal more frequently than less comminuted fractures. Less callus formed in fractures with nonunions and in patients treated with stainless steel plates compared with titanium plates. Complications occurred in 28 of 70 fractures (40%), 19 of which had additional surgery. CONCLUSIONS: We found a high rate of nonunion in distal femur fractures treated with locking plates. Nonunion presented late without hardware failure and with limited callus formation suggesting callus inhibition rather than hardware failure is the primary problem. Mechanical factors may play a role in the high rate of nonunion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Baker, S. P., O’Neill, B., Haddon, W. F., & Long, W. B. (1974) · PubMed · Cited by 7,946
Gustilo, R., & Anderson, J. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658040-00004 · Cited by 3,306
GUSTILO, R. B., & ANDERSON, J. T. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200204000-00029 · Cited by 2,789
Horan, T. C., Gaynes, R. P., Martone, W. J., Jarvis, W. R., & Grace Emori, T. (1992) · American Journal of Infection Control · doi:10.1016/s0196-6553(05)80201-9 · Cited by 2,609 · cited 1×
“for Disease Control and Prevention definition as superficial or deep [10].”
BackgroundHoran, T. C., Gaynes, R. P., Martone, W. J., Jarvis, W. R., & Emori, T. G. (1992) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700015241 · Cited by 1,396
Effects of Mechanical Factors on the Fracture Healing Process
Claes, L. E., Heigele, C. A., Neidlinger-Wilke, C., Kaspar, D., Seidl, W., Margevicius, K. J., & Augat, P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00015 · Cited by 705 · cited 2×
“callus formation, and interfragmentary motion in the millimeter range is known to induce bone healing that does not occur with less motion [3, 13].”
BackgroundMethodBiomechanical testing of the LCP – how can stability in locked internal fixators be controlled?
Stoffel, K., Dieter, U., Stachowiak, G., Gächter, A., & Kuster, M. S. (2003) · Injury · doi:10.1016/j.injury.2003.09.021 · Cited by 657
Variability in the Assessment of Fracture-Healing in Orthopaedic Trauma Studies
Corrales, L. A., Morshed, S., Bhandari, M., & Miclau, T. (2008) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.01580 · Cited by 415 · cited 1×
“The formation of bridging callus on radiographs and the ability to bear weight without pain are the most frequently used criteria for fracture union in reported clinical series and were used in this study [3, 4].”
MethodKEATING, J. F., OʼBRIEN, P. J., BLACHUT, P. A., MEEK, R. N., & BROEKHUYSE, H. M. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199703000-00003 · Cited by 321 · cited 1×
“Serial orthogonal radiographs taken at 6 weeks, 3 months, and 6 months after the fracture were reviewed by one observer (CEH) who was not a treating surgeon, to assess union by identifying bridging callus of at least two cortices [12, 22, 23].”
MethodLocked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus Formation
Lujan, T. J., Henderson, C. E., Madey, S. M., Fitzpatrick, D. C., Marsh, J. L., & Bottlang, M. (2010) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e3181be6720 · Cited by 290 · cited 5×
“An established algorithm was used to objectify the measurement of callus size [ 18 , 19].”
BackgroundMethodInfluentialSelf-citation
Cited by
Smart implants in fracture care – Only buzzword or real opportunity
Ernst, M., Richards, R. G., & Windolf, M. (2021) · Injury · doi:10.1016/j.injury.2020.09.026 · Cited by 50
Metadata
- Authors
- Henderson, C. E., Lujan, T. J., Kuhl, L. L., Bottlang, M., Fitzpatrick, D. C., & Marsh, J. L.
- Venue
- Clinical Orthopaedics & Related Research
- Published
- 2011-06
- Volume
- 469
- Issue
- 6
- Pages
- 1757-1765
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2144456178
- Cited by
- 231
- References
- 15
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.