Glidescope® video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The Glidescope(®) video-laryngoscopy appears to provide better glottic visualization than direct laryngoscopy. However, it remains unclear if it translates into increased success with intubation. METHODS: We systematically searched electronic databases, conference abstracts, and article references. We included trials in humans comparing Glidescope(®) video-laryngoscopy to direct laryngoscopy regarding the glottic view, successful first-attempt intubation, and time to intubation. We generated pooled risk ratios or weighted mean differences across studies. Meta-regression was used to explore heterogeneity based on operator expertise and intubation difficulty. RESULTS: We included 17 trials with a total of 1,998 patients. The pooled relative risk (RR) of grade 1 laryngoscopy (vs ≥ grade 2) for the Glidescope(®) was 2.0 [95% confidence interval (CI) 1.5 to 2.5]. Significant heterogeneity was partially explained by intubation difficulty using meta-regression analysis (P = 0.003). The pooled RR for nondifficult intubations of grade 1 laryngoscopy (vs ≥ grade 2) was 1.5 (95% CI 1.2 to 1.9), and for difficult intubations it was 3.5 (95% CI 2.3 to 5.5). There was no difference between the Glidescope(®) and the direct laryngoscope regarding successful first-attempt intubation or time to intubation, although there was significant heterogeneity in both of these outcomes. In the two studies examining nonexperts, successful first-attempt intubation (RR 1.8, 95% CI 1.4 to 2.4) and time to intubation (weighted mean difference -43 sec, 95% CI -72 to -14 sec) were improved using the Glidescope(®). These benefits were not seen with experts. CONCLUSION: Compared to direct laryngoscopy, Glidescope(®) video-laryngoscopy is associated with improved glottic visualization, particularly in patients with potential or simulated difficult airways.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gotzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · BMJ · doi:10.1136/bmj.b2700 · Cited by 17,648
The combination of estimates from different experiments
Cochran, W. G. (1954) · Biometrics · doi:10.2307/3001666 · Cited by 5,380 · cited 1×
“0) Malik 2009(26) 22/3/0/0 2/15/6/2 22/25 (88%) 17/25 (68%) 17 (12-31) 13 (8-23) Morello 2009(33) 239/61/0/0 128/152/20/0 134/150 (89%) 95/150 (63%) NR NR Nouruzi-Sedeh 2009(14) 66/26/5/3 32/18/37/13 93/100 (93%) 51/100 (51%) 63 (30) 89 (35) Robitaille 2008(29) 10/10/0/0 0/19/1/0 NR NR NR NR Serocki 2010(24) 43/75/2/0…”
How should meta‐regression analyses be undertaken and interpreted?
Thompson, S. G., & Higgins, J. P. T. (2002) · Statistics in Medicine · doi:10.1002/sim.1187 · Cited by 3,026
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471
The appropriateness of asymmetry tests for publication bias in meta-analyses: A large survey
Ioannidis, J. P. A., & Trikalinos, T. A. (2007) · Canadian Medical Association Journal · doi:10.1503/cmaj.060410 · Cited by 1,052 · cited 1×
“8) Sun 2005(15) 75/24/1/0 59/26/15/0 94/100 (94%) 97/100 (97%) 46 (43-49) 30 (28-33) Teoh 2009(27) 78/21/1/0 58/37/5/0 91/100 (91%) 98/100 (98%) 31.”
(2005) · Circulation · doi:10.1161/circulationaha.105.166550 · Cited by 1,000
Shiga, T., Wajima, Z., Inoue, T., & Sakamoto, A. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00027 · Cited by 902
Schwartz, D. E., Matthay, M. A., & Cohen, N. H. (1995) · Anesthesiology · doi:10.1097/00000542-199502000-00007 · Cited by 676
Jaber, S., Amraoui, J., Lefrant, J.-Y., Arich, C., Cohendy, R., Landreau, L., Calvet, Y., Capdevila, X., Mahamat, A., & Eledjam, J.-J. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000233879.58720.87 · Cited by 675
The airway: problems and predictions in 18,500 patients
Rose, D. K., & Cohen, M. M. (1994) · Canadian Journal of Anaesthesia · doi:10.1007/bf03009858 · Cited by 645
The unanticipated difficult airway with recommendations for management
Crosby, E. T., Cooper, R. M., Douglas, M. J., Doyle, D. J., Hung, O. R., Labrecque, P., Muir, H., Murphy, M. F., Preston, R. P., Rose, D. K., et al. (1998) · Canadian Journal of Anaesthesia · doi:10.1007/bf03012147 · Cited by 615
Early clinical experience with a new videolaryngoscope (GlideScope®) in 728 patients
Cooper, R. M., Pacey, J. A., Bishop, M. J., & McCluskey, S. A. (2005) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03027728 · Cited by 562
Preoperative Airway Assessment: Predictive Value of a Multivariate Risk Index
El-Ganzouri, A. R., McCarthy, R. J., Tuman, K. J., Tanck, E. N., & Ivankovich, A. D. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199606000-00017 · Cited by 553
Complications of endotracheal intubation in the critically ill
Griesdale, D. E. G., Bosma, T. L., Kurth, T., Isac, G., & Chittock, D. R. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1205-6 · Cited by 443
Self-citationRelative Risk Analysis of Factors Associated with Difficult Intubation in Obstetric Anesthesia
Rocke, D. A., Murray, W. B., Rout, C. C., & Gouws, E. (1992) · Anesthesiology · doi:10.1097/00000542-199207000-00010 · Cited by 402
Aziz, M. F., Healy, D., Kheterpal, S., Fu, R. F., Dillman, D., & Brambrink, A. M. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3182023eb7 · Cited by 395
The GlideScope® Video Laryngoscope: randomized clinical trial in 200 patients
Sun, D. A., Warriner, C. B., Parsons, D. G., Klein, R., Umedaly, H. S., & Moult, M. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei041 · Cited by 359
Trends in Anesthesia-related Death and Brain Damage: A Closed Claims Analysis
Cheney, F. W., Posner, K. L., Lee, L. A., Caplan, R. A., & Domino, K. B. (2006) · Anesthesiology · doi:10.1097/00000542-200612000-00007 · Cited by 286
Turkstra, T. P., Craen, R. A., Pelz, D. M., & Gelb, A. W. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000166975.38649.27 · Cited by 238
Nouruzi-Sedeh, P., Schumann, M., & Groeben, H. (2009) · Anesthesiology · doi:10.1097/aln.0b013e318190b6a7 · Cited by 238
Malik, M. A., Maharaj, C. H., Harte, B. H., & Laffey, J. G. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen231 · Cited by 229
Predicting difficult intubation: a multivariable analysis
Karkouti, K., Rose, D. K., Wigglesworth, D., & Cohen, M. M. (2000) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03019474 · Cited by 192
Robitaille, A., Williams, S. R., Tremblay, M.-H., Guilbert, F., Thériault, M., & Drolet, P. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318161769e · Cited by 191
Mihai, R., Blair, E., Kay, H., & Cook, T. M. (2008) · Anaesthesia · doi:10.1111/j.1365-2044.2008.05489.x · Cited by 179
Serocki, G., Bein, B., Scholz, J., & Dörges, V. (2010) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32832d328d · Cited by 171
Malik, M. A., Subramaniam, R., Maharaj, C. H., Harte, B. H., & Laffey, J. G. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep266 · Cited by 163
The incidence of airway problems depends on the definition used
Rose, D., & Cohen, M. M. (1996) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03015954 · Cited by 152
Lim, Y., & Yeo, S. W. (2005) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0503300215 · Cited by 113
A Comparison of GlideScope® Videolaryngoscopy to Direct Laryngoscopy for Nasotracheal Intubation
Jones, P. M., Armstrong, K., Armstrong, P. M., Cherry, R. A., Harle, C. C., Hoogstra, J., & Turkstra, T. P. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31816d15c9 · Cited by 104
Urgent tracheal intubation in general hospital units: an observational study
Benedetto, W. J., HESS, D. R., Gettings, E. M., Bigatello, L. M., Toon, H., Hurford, W. E., & Schmidt, U. H. (2007) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2006.05.018 · Cited by 84
Reade, M. C., Delaney, A., Bailey, M. J., & Angus, D. C. (2008) · Critical Care · doi:10.1186/cc6941 · Cited by 72
Xue, F., Zhang, G. H., Li, X. Y., et al. (2007) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2006.11.004 · Cited by 72
Teoh, W. H., Shah, M. K., & Sia, A. T. H. (2009) · Anaesthesia · doi:10.1111/j.1365-2044.2009.06032.x · Cited by 50
Influence of residency training on multiple attempts at endotracheal intubation
Hirsch-Allen, A., Ayas, N., Mountain, S., et al. (2010) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-010-9345-x · Cited by 39
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., Schofield-Robinson, O. J., & Smith, A. F. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex228 · Cited by 359
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Self-citationDe Jong, A., Molinari, N., Conseil, M., Coisel, Y., Pouzeratte, Y., Belafia, F., Jung, B., Chanques, G., & Jaber, S. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3236-5 · Cited by 190
Metadata
- Authors
- Griesdale, D. E. G., Liu, D., McKinney, J., & Choi, P. T.
- Venue
- Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Published
- 2011-11-01
- Volume
- 59
- Issue
- 1
- Pages
- 41-52
- ISSN
- 0832-610X (ISSN-L)
- 1496-8975
- OpenAlex
- W1531030680
- Cited by
- 363
- References
- 36
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.