CoChat

Real-World Variability in the Prediction of Intracranial Aneurysm Wall Shear Stress: The 2015 International Aneurysm CFD Challenge

Open access

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

Abstract

PURPOSE: Image-based computational fluid dynamics (CFD) is widely used to predict intracranial aneurysm wall shear stress (WSS), particularly with the goal of improving rupture risk assessment. Nevertheless, concern has been expressed over the variability of predicted WSS and inconsistent associations with rupture. Previous challenges, and studies from individual groups, have focused on individual aspects of the image-based CFD pipeline. The aim of this Challenge was to quantify the total variability of the whole pipeline. METHODS: 3D rotational angiography image volumes of five middle cerebral artery aneurysms were provided to participants, who were free to choose their segmentation methods, boundary conditions, and CFD solver and settings. Participants were asked to fill out a questionnaire about their solution strategies and experience with aneurysm CFD, and provide surface distributions of WSS magnitude, from which we objectively derived a variety of hemodynamic parameters. RESULTS: A total of 28 datasets were submitted, from 26 teams with varying levels of self-assessed experience. Wide variability of segmentations, CFD model extents, and inflow rates resulted in interquartile ranges of sac average WSS up to 56%, which reduced to < 30% after normalizing by parent artery WSS. Sac-maximum WSS and low shear area were more variable, while rank-ordering of cases by low or high shear showed only modest consensus among teams. Experience was not a significant predictor of variability. CONCLUSIONS: Wide variability exists in the prediction of intracranial aneurysm WSS. While segmentation and CFD solver techniques may be difficult to standardize across groups, our findings suggest that some of the variability in image-based CFD could be reduced by establishing guidelines for model extents, inflow rates, and blood properties, and by encouraging the reporting of normalized hemodynamic parameters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s13239-018-00374-2

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Representative segmentations of the five MCA aneurysm cases, showing the sac (pink) and parent artery (cyan) segments over which WSS was objectively averaged as described in the Methods. The * in each panel identifies dominant outflow branch, used to define the outflow division for all teams.
Figure 1 Representative segmentations of the five MCA aneurysm cases, showing the sac (pink) and parent artery (cyan) segments over which WSS was objectively averaged as described in the Methods. The * in each panel identifies dominant outflow branch, used to define the outflow division for all teams.CC BY · PubMed Central
Figure 2 Variability of CFD model domains. (a) shows Case 1 at full size, while (b–e) show Cases 2–5 at reduced size in the interest of space. For each case, models are shown from top left to bottom right in descending order of team experience indicated in the top right corner of each panel: 3 = high; 2 = medium; 1/0 = low. Team number is shown at bottom right of each panel. For each case, models are all shown in the same view, but obviously not to the same scale.
Figure 2 Variability of CFD model domains. (a) shows Case 1 at full size, while (b–e) show Cases 2–5 at reduced size in the interest of space. For each case, models are shown from top left to bottom right in descending order of team experience indicated in the top right corner of each panel: 3 = high; 2 = medium; 1/0 = low. Team number is shown at bottom right of each panel. For each case, models are all shown in the same view, but obviously not to the same scale.CC BY · PubMed Central
Figure 3 Variability of segmentations, focusing on the aneurysm and parent artery, with (a–e) showing Cases 1–5. Unlike Fig. 2, models are now zoomed in and, for each case, shown to the same scale in order to appreciate qualitative differences in sac and neck morphology, parent artery dimensions, and smoothness. As the surfaces are derived from the team-contributed WSS fields, mesh density may also be inferred from the faceting of the shaded surface. Experience levels and team numbers are shown in each panel, as explained in the caption of Fig. 2.
Figure 3 Variability of segmentations, focusing on the aneurysm and parent artery, with (a–e) showing Cases 1–5. Unlike Fig. 2, models are now zoomed in and, for each case, shown to the same scale in order to appreciate qualitative differences in sac and neck morphology, parent artery dimensions, and smoothness. As the surfaces are derived from the team-contributed WSS fields, mesh density may also be inferred from the faceting of the shaded surface. Experience levels and team numbers are shown in each panel, as explained in the caption of Fig. 2.CC BY · PubMed Central
Figure 4 Variability of selected inflow/outflow parameters derived as described in the Methods. Green squares, yellow circles and red triangles identify data from teams with high, medium and low experience, respectively. Thicker symbols highlight the teams that contributed CFD datasets from two different segmentations. Superimposed horizontal lines, boxes, and whiskers identify median, IQR, and 90th percentile ranges for each case.
Figure 4 Variability of selected inflow/outflow parameters derived as described in the Methods. Green squares, yellow circles and red triangles identify data from teams with high, medium and low experience, respectively. Thicker symbols highlight the teams that contributed CFD datasets from two different segmentations. Superimposed horizontal lines, boxes, and whiskers identify median, IQR, and 90th percentile ranges for each case.CC BY · PubMed Central
Figure 5 Variability of absolute WSS, with (a–e) showing Cases 1–5. WSS values are plotted from 0 to 15 Pa using the colour scale shown in the top left panels. Experience levels and team numbers are shown in each panel, as explained in the caption of Fig. 2.
Figure 5 Variability of absolute WSS, with (a–e) showing Cases 1–5. WSS values are plotted from 0 to 15 Pa using the colour scale shown in the top left panels. Experience levels and team numbers are shown in each panel, as explained in the caption of Fig. 2.CC BY · PubMed Central
Figure 6 Variability of normalized WSS*, with (a–e) showing Cases 1–5. WSS* values are plotted from 0 to 2 using the colour scale shown in the top left panels, where WSS* = 1 corresponds to the nominal parent artery value. Experience levels and team numbers are shown in each panel, as explained in the caption of Fig. 2.
Figure 6 Variability of normalized WSS*, with (a–e) showing Cases 1–5. WSS* values are plotted from 0 to 2 using the colour scale shown in the top left panels, where WSS* = 1 corresponds to the nominal parent artery value. Experience levels and team numbers are shown in each panel, as explained in the caption of Fig. 2.CC BY · PubMed Central
Figure 7 Variability of selected sac hemodynamic parameters derived as described in the Methods. See caption of Fig. 4 for explanation of symbols and box/whisker plots.
Figure 7 Variability of selected sac hemodynamic parameters derived as described in the Methods. See caption of Fig. 4 for explanation of symbols and box/whisker plots.CC BY · PubMed Central
Figure 8 Variability of team rank-ordering of cases according the various hemodynamic parameters. In this bubble chart, the number of teams at each rank is proportional to the bubble area, while the proportion of high, medium and low experience teams at each rank is indicated by the green, yellow and red slices. The large, fainter bubbles in the top left panel indicate what one of these charts would look like for perfect agreement among all teams.
Figure 8 Variability of team rank-ordering of cases according the various hemodynamic parameters. In this bubble chart, the number of teams at each rank is proportional to the bubble area, while the proportion of high, medium and low experience teams at each rank is indicated by the green, yellow and red slices. The large, fainter bubbles in the top left panel indicate what one of these charts would look like for perfect agreement among all teams.CC BY · PubMed Central
Figure 9 Comparison of calculated vs. reported quantities for (a) MCA flow rate and (b) sac-averaged WSS magnitude, i.e., AWSS. Data points are based on each team’s average across the five cases, and team numbers are shown for apparent outliers. See caption of Fig. 4 for explanation of symbols.
Figure 9 Comparison of calculated vs. reported quantities for (a) MCA flow rate and (b) sac-averaged WSS magnitude, i.e., AWSS. Data points are based on each team’s average across the five cases, and team numbers are shown for apparent outliers. See caption of Fig. 4 for explanation of symbols.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 128

Metadata

Authors
Valen-Sendstad, K., Bergersen, A. W., Shimogonya, Y., Goubergrits, L., Bruening, J., Pallares, J., Cito, S., Piskin, S., Pekkan, K., Geers, A. J., Larrabide, I., Rapaka, S., Mihalef, V., Fu, W., Qiao, A., Jain, K., Roller, S., Mardal, K.-A., Kamakoti, R., Spirka, T., Ashton, N., Revell, A., Aristokleous, N., Houston, J. G., Tsuji, M., Ishida, F., Menon, P. G., Browne, L. D., Broderick, S., Shojima, M., Koizumi, S., Barbour, M., Aliseda, A., Morales, H. G., Lefèvre, T., Hodis, S., Al-Smadi, Y. M., Tran, J. S., Marsden, A. L., Vaippummadhom, S., Einstein, G. A., Brown, A. G., Debus, K., Niizuma, K., Rashad, S., Sugiyama, S.-I., Owais Khan, M., Updegrove, A. R., Shadden, S. C., Cornelissen, B. M. W., Majoie, C. B. L. M., Berg, P., Saalfield, S., Kono, K., & Steinman, D. A.
Affiliations
  • University of Oslo (NO)
  • Nihon University (JP)
  • Charité – Universitätsmedizin Berlin (DE)
  • Universitat Rovira i Virgili (ES)
  • Koç University (TR)
  • Universitat Pompeu Fabra (ES)
  • Universidad Nacional del Centro de la Provincia de Buenos Aires (AR)
  • Siemens Healthcare (United States) (US)
  • Beijing Union University (CN)
  • Beijing University of Technology (CN)
  • University of Zurich (CH)
  • University of Siegen (DE)
  • Simpleware (United Kingdom) (GB)
  • University of Oxford (GB)
  • University of Manchester (GB)
  • University of Limerick (IE)
  • University of Dundee (GB)
  • Mie Chuo Medical Center (JP)
  • University of Pittsburgh (US)
  • The University of Tokyo (JP)
  • University of Washington (US)
  • Philips (France) (FR)
  • Texas A&M University – Kingsville (US)
  • Jordan University of Science and Technology (JO)
  • Stanford University (US)
  • Tohoku University (JP)
  • Kohnan Hospital (JP)
  • University of California, Berkeley (US)
  • Amsterdam UMC Location University of Amsterdam (NL)
  • Otto-von-Guericke-Universität Magdeburg (DE)
  • Wakayama Rosai Hospital (JP)
  • University of Toronto (CA)
Corresponding author
Steinman, David A.
Venue
Cardiovascular Engineering and Technology
Published
2018-09-10
Volume
9
Issue
4
Pages
544-564
ISSN
  • 1869-408X (ISSN-L)
  • 1869-4098
OpenAlex
W2890609830
Cited by
128
References
50
Citations by year
2026: 12 · 2025: 19 · 2024: 22 · 2023: 12 · 2022: 10 · 2021: 26 · 2020: 13 · 2019: 12 · 2018: 2
FWCI
9.00
Type
journal article
Language
en
Open access
Licence
  • cc-by
  • creativecommons.org/licenses/by/4.0 (tdm)
Locations
  • Cardiovascular Engineering and Technology (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Research Explorer (The University of Manchester) (publishedVersion, cc-by)
  • University of Limerick Institutional Repository (University of Limerick) (acceptedVersion, other-oa)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
  • Arrow@dit (Dublin Institute of Technology) (submittedVersion, cc-by-nc-sa)
  • Discovery Research Portal (University of Dundee) (submittedVersion, cc-by)
  • Figshare (submittedVersion, cc-by-nc-sa)
  • Institutional Repositories DataBase (IRDB) (submittedVersion)
  • Pure Amsterdam UMC (submittedVersion, other-oa)
  • CONICET Digital (CONICET) (submittedVersion, cc-by)
Funders
  • Heart and Stroke Foundation of Canada (MC7455)
  • Norges Forskningsråd (179578, 203489/O30, 262827)
Topics
  • Health Sciences › Medicine › Clinical Neurology › Intracranial Aneurysms: Treatment and Complications
  • Health Sciences › Medicine › Surgery › Aortic aneurysm repair treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cerebrovascular and Carotid Artery Diseases
Keywords
intracranial aneurysm, wall shear stress, image-based computational fluid dynamics, aneurysm rupture risk, interobserver variability, middle cerebral artery aneurysm, 3D rotational angiography, segmentation variability, hemodynamic parameters
MeSH terms
Blood Flow Velocity, Intracranial Aneurysm, Cerebral Angiography, Cerebrovascular Circulation, Hemodynamics, Humans, Models, Cardiovascular, Predictive Value of Tests, Prognosis, Radiographic Image Interpretation, Computer-Assisted, Regional Blood Flow, Stress, Mechanical, Reproducibility of Results, Middle Cerebral Artery, Imaging, Three-Dimensional, Patient-Specific Modeling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.