The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Detector-based spectral CT with a novel dual-layer technology: principles and applications
Open accessAbstract
Detector-based spectral computed tomography is a novel dual-energy CT technology that employs two layers of detectors to simultaneously collect low- and high-energy data in all patients using standard CT protocols. In addition to the conventional polyenergetic images created for each patient, projection-space decomposition is used to generate spectral basis images (photoelectric and Compton scatter) for creating multiple spectral images, including material decomposition (iodine-only, virtual non-contrast, effective atomic number) and virtual monoenergetic images, on-demand according to clinical need. These images are useful in multiple clinical applications, including- improving vascular contrast, improving lesion conspicuity, decreasing artefacts, material characterisation and reducing radiation dose. In this article, we discuss the principles of this novel technology and also illustrate the common clinical applications. Teaching points • The top and bottom layers of dual-layer CT absorb low- and high-energy photons, respectively.• Multiple spectral images are generated by projection-space decomposition.• Spectral images can be generated in all patients scanned in this scanner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Schlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 801
Dual-Energy CT: General Principles
Johnson, T. R. C. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.9116 · Cited by 631
Evaluation of a prototype dual‐energy computed tomographic apparatus. I. Phantom studies
Kalender, W. A., Perman, W. H., Vetter, J. R., & Klotz, E. (1986) · Medical Physics · doi:10.1118/1.595958 · Cited by 451
State of the Art: Dual-Energy CT of the Abdomen
Marin, D., Boll, D. T., Mileto, A., & Nelson, R. C. (2014) · Radiology · doi:10.1148/radiol.14131480 · Cited by 368
Pelgrim, G. J., van Hamersvelt, R. W., Willemink, M. J., Schmidt, B. T., Flohr, T., Schilham, A., Milles, J., Oudkerk, M., Leiner, T., & Vliegenthart, R. (2017) · European Radiology · doi:10.1007/s00330-017-4752-9 · Cited by 192
Chandarana, H., Godoy, M. C. B., Vlahos, I., Graser, A., Babb, J., Leidecker, C., & Macari, M. (2008) · Radiology · doi:10.1148/radiol.2492080359 · Cited by 164
Dual-Energy CT: Vascular Applications
Vlahos, I., Chung, R., Nair, A., & Morgan, R. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.9114 · Cited by 120
Ho, L. M., Marin, D., Neville, A. M., Barnhart, H. X., Gupta, R. T., Paulson, E. K., & Boll, D. T. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.7316 · Cited by 112
Cited by
Roski, F., Hammel, J., Mei, K., Baum, T., Kirschke, J. S., Laugerette, A., Kopp, F. K., Bodden, J., Pfeiffer, D., Pfeiffer, F., et al. (2019) · European Radiology · doi:10.1007/s00330-019-06263-z · Cited by 70
Metadata
- Authors
- Rassouli, N., Etesami, M., Dhanantwari, A., & Rajiah, P.
- Venue
- Insights into Imaging
- Published
- 2017-10-06
- Volume
- 8
- Issue
- 6
- Pages
- 589-598
- ISSN
- 1869-4101 (ISSN-L)
- OpenAlex
- W2763781088
- Cited by
- 300
- References
- 12
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detector-based spectral CT with a novel dual-layer technology: principles and applications. https://app.cochat.ai/papers/10.1007/s13244-017-0571-4
- The paper
- Rassouli, N., Etesami, M., Dhanantwari, A., & Rajiah, P. (2017). Detector-based spectral CT with a novel dual-layer technology: principles and applications. Insights into Imaging. https://doi.org/10.1007/s13244-017-0571-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.