High-Speed MALDI-TOF Imaging Mass Spectrometry: Rapid Ion Image Acquisition and Considerations for Next Generation Instrumentation
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
A prototype matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometer has been used for high-speed ion image acquisition. The instrument incorporates a Nd:YLF solid state laser capable of pulse repetition rates up to 5 kHz and continuous laser raster sampling for high-throughput data collection. Lipid ion images of a sagittal rat brain tissue section were collected in 10 min with an effective acquisition rate of roughly 30 pixels/s. These results represent more than a 10-fold increase in throughput compared with current commercially available instrumentation. Experiments aimed at improving conditions for continuous laser raster sampling for imaging are reported, highlighting proper laser repetition rates and stage velocities to avoid signal degradation from significant oversampling. As new high spatial resolution and large sample area applications present themselves, the development of high-speed microprobe MALDI imaging mass spectrometry is essential to meet the needs of those seeking new technologies for rapid molecular imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637 · cited 1×
“MALDI is performed by co-crystallizing or coating the sample with a matrix that efficiently absorbs the energy of the incident laser beam [17].”
BackgroundMolecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234 · cited 1×
“The emergence of matrix-assisted laser desorption ionization imaging mass spectrometry [MALDI imaging mass spectrometry (IMS)] as a prominent analytical tool [1] has helped drive advancements in instrumentation, lasers, data acquisition methods, and data processing packages.”
MethodSelf-citationMcDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
MALDI imaging mass spectrometry: molecular snapshots of biochemical systems
Cornett, D. S., Reyzer, M. L., Chaurand, P., & Caprioli, R. M. (2007) · Nature Methods · doi:10.1038/nmeth1094 · Cited by 886 · cited 1×
“The technology has rapidly developed into a powerful analytical tool able to spatially resolve biologically relevant molecules such as pharmaceuticals, metabolites, lipids, peptides and proteins [2–6], providing a new molecular dimension to classic histology.”
BackgroundSelf-citationSublimation as a method of matrix application for mass spectrometric imaging
Hankin, J. A., Barkley, R. M., & Murphy, R. C. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.06.010 · Cited by 598 · cited 1×
“Tissue samples were cryosectioned (12 μm thickness), thaw-mounted on gold-coated plates, and dried in a vacuum dessiccator (~2 h) prior to application of DHB by sublimation (120°C, 50 mTorr, 5.5 min) [ 21 ].”
MethodInfluentialA concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416 · cited 1×
“The technology has rapidly developed into a powerful analytical tool able to spatially resolve biologically relevant molecules such as pharmaceuticals, metabolites, lipids, peptides and proteins [2–6], providing a new molecular dimension to classic histology.”
BackgroundGroseclose, M. R., Massion, P. P., Chaurand, P., & Caprioli, R. M. (2008) · PROTEOMICS · doi:10.1002/pmic.200800495 · Cited by 319 · cited 1×
“The same consideration applies to sampling larger areas for applications such as determining molecular distributions in whole-body tissue cross sections [10–13] and biomarker discovery using tissue microarrays [14–16].”
BackgroundSelf-citationAutoradiography, MALDI-MS, and SIMS-MS Imaging in Pharmaceutical Discovery and Development
Solon, E. G., Schweitzer, A., Stoeckli, M., & Prideaux, B. (2010) · The AAPS Journal · doi:10.1208/s12248-009-9158-4 · Cited by 250 · cited 1×
“The same consideration applies to sampling larger areas for applications such as determining molecular distributions in wholebody tissue cross sections [10–13] and biomarker discovery using tissue microarrays [14–16].”
BackgroundTrim, P. J., Henson, C. M., Avery, J. L., McEwen, A., Snel, M. F., Claude, E., Marshall, P. S., West, A., Princivalle, A. P., & Clench, M. R. (2008) · Analytical Chemistry · doi:10.1021/ac8015467 · Cited by 197
Optimizing UV laser focus profiles for improved MALDI performance
Holle, A., Haase, A., Kayser, M., & Höhndorf, J. (2006) · Journal of Mass Spectrometry · doi:10.1002/jms.1041 · Cited by 167 · cited 1×
“MALDI applications and the ability to operate at pulse repetition rates 91 kHz with much longer life spans (typically 910(9) shots) than N2 lasers make them preferred for highthroughput experiments [7, 18].”
BackgroundPeptide and protein imaging mass spectrometry in cancer research
McDonnell, L. A., Corthals, G. L., Willems, S. M., van Remoortere, A., van Zeijl, R. J. M., & Deelder, A. M. (2010) · Journal of Proteomics · doi:10.1016/j.jprot.2010.05.007 · Cited by 161 · cited 1×
“The technology has rapidly developed into a powerful analytical tool able to spatially resolve biologically relevant molecules such as pharmaceuticals, metabolites, lipids, peptides and proteins [2–6], providing a new molecular dimension to classic histology.”
BackgroundJun, J. H., Song, Z., Liu, Z., Nikolau, B. J., Yeung, E. S., & Lee, Y. (2010) · Analytical Chemistry · doi:10.1021/ac902990p · Cited by 157
Mass spectrometric imaging of small molecules
Svatoš, A. (2010) · Trends in biotechnology · doi:10.1016/j.tibtech.2010.05.005 · Cited by 144 · cited 1×
“The technology has rapidly developed into a powerful analytical tool able to spatially resolve biologically relevant molecules such as pharmaceuticals, metabolites, lipids, peptides and proteins [2–6], providing a new molecular dimension to classic histology.”
BackgroundNovel molecular tumour classification using MALDI–mass spectrometry imaging of tissue micro-array
Djidja, M., Claude, E., Snel, M. F., Francese, S., Scriven, P., Carolan, V. A., & Clench, M. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3554-6 · Cited by 129
Imaging mass spectrometry of gastric carcinoma in formalin‐fixed paraffin‐embedded tissue microarray
Morita, Y., Ikegami, K., Goto-Inoue, N., Hayasaka, T., Zaima, N., Tanaka, H., Uehara, T., Setoguchi, T., Sakaguchi, T., Igarashi, H., et al. (2009) · Cancer Science · doi:10.1111/j.1349-7006.2009.01384.x · Cited by 97
Trim, P. J., Djidja, M., Atkinson, S. J., Oakes, K., Cole, L. M., Anderson, D. M., Hart, P. J., Francese, S., & Clench, M. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3874-6 · Cited by 95 · cited 1×
“A recent report described a modified hybrid quadrupole time-of-flight MS with a Nd: YVO4 laser capable of pulse repetition rates up to 20 kHz [19].”
BackgroundImaging of aβ-peptide distribution in whole-body mice sections by MALDI mass spectrometry
Stoeckli, M., Staab, D., Schweitzer, A., Gardiner, J., & Seebàch, D. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.08.005 · Cited by 94
Modern MALDI time‐of‐flight mass spectrometry
Vestal, M. L. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1537 · Cited by 78 · cited 1×
“Theoretical and instrumental design considerations have been described previously [22–24].”
BackgroundHankin, J. A., & Murphy, R. C. (2010) · Analytical Chemistry · doi:10.1021/ac101079v · Cited by 67 · cited 1×
“These results are consistent with those previously reported in the literature [25, 26].”
Resultvan Remoortere, A., Jones, E. A., Deelder, A. M., & McDonnell, L. A. (2012) · Wiley eBooks · doi:10.1002/9780470921920.edm098 · Cited by 61
Cited by
Norris, J. L., & Caprioli, R. M. (2013) · Chemical Reviews · doi:10.1021/cr3004295 · Cited by 696
Self-citationTaylor, M. J., Lukowski, J. K., & Anderton, C. R. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00439 · Cited by 302
Mass spectrometry imaging for drug distribution studies
Prideaux, B., & Stoeckli, M. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.07.028 · Cited by 279
MALDI imaging mass spectrometry: Spatial molecular analysis to enable a new age of discovery
Gessel, M. M., Norris, J. L., & Caprioli, R. M. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2014.03.021 · Cited by 276
Self-citationSpraggins, J. M., Djambazova, K. V., Rivera, E. S., Migas, L. G., Neumann, E. K., Fuetterer, A., Suetering, J., Goedecke, N., Ly, A., Van de Plas, R., et al. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03612 · Cited by 237
Self-citation
Metadata
- Authors
- Spraggins, J. M., & Caprioli, R. M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-04-09
- Volume
- 22
- Issue
- 6
- Pages
- 1022-1031
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2063187819
- Cited by
- 170
- References
- 20
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.