A Novel 9.4 Tesla FTICR Mass Spectrometer with Improved Sensitivity, Mass Resolution, and Mass Range
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Fourier transform ion cyclotron resonance (FTICR) mass spectrometry provides unparalleled mass measurement accuracy and resolving power. However, propagation of the technique into new analytical fields requires continued advances in instrument speed and sensitivity. Here, we describe a substantial redesign of our custom-built 9.4 tesla FTICR mass spectrometer that improves sensitivity, acquisition speed, and provides an optimized platform for future instrumentation development. The instrument was designed around custom vacuum chambers for improved ion optical alignment, minimized distance from the external ion trap to magnetic field center, and high conductance for effective differential pumping. The length of the transfer optics is 30% shorter than the prior system, for reduced time-of-flight mass discrimination and increased ion transmission and trapping efficiency at the ICR cell. The ICR cell, electrical vacuum feedthroughs, and cabling have been improved to reduce the detection circuit capacitance (and improve detection sensitivity) 2-fold. The design simplifies access to the ICR cell, and the modular vacuum flange accommodates new ICR cell technology, including linearized excitation, high surface area detection, and tunable electrostatic trapping potential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990 · cited 1×
“Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) offers the highest resolving power m/Δm50% (Δm50% is the full peak width at half-maximum peak height) and mass measurement accuracy of any mass analyzer [1, 2].”
BackgroundSelf-citationElectron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881 · cited 8×
“The precursor ions were isolated by the quadrupole mass filter and accumulated externally before transfer to the ICR cell for ECD or IRMPD.”
MethodInfluentialFourier transform ion cyclotron resonance spectroscopy
Comisarow, M. B., & Marshall, A. G. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)89137-2 · Cited by 1,038 · cited 1×
“Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) offers the highest resolving power m/Δm50% (Δm50% is the full peak width at half-maximum peak height) and mass measurement accuracy of any mass analyzer [1, 2].”
BackgroundSelf-citationHughey, C. A., Hendrickson, C. L., Rodgers, R. P., Marshall, A. G., & Qian, K. (2001) · Analytical Chemistry · doi:10.1021/ac010560w · Cited by 851 · cited 1×
“Elemental compositions in petroleum naturally form homologous series, providing for identification of components up to ~1,000 Da [55].”
BackgroundSelf-citationPetroleomics: The Next Grand Challenge for Chemical Analysis
Marshall, A. G., & Rodgers, R. P. (2004) · Accounts of Chemical Research · doi:10.1021/ar020177t · Cited by 817 · cited 1×
“Longer time-domain transient lifetime is needed for greater resolving power, to resolve isobaric species and to assign elemental composition at high m/z [15, 16].”
BackgroundSelf-citationPetroleomics: Chemistry of the underworld
Marshall, A. G., & Rodgers, R. P. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805069105 · Cited by 673 · cited 2×
“FTICR is uniquely suited to analysis of complex natural organic mixtures, such as petroleum crude oil [9] and humic/fulvic acids [10].”
BackgroundSelf-citationStenson, A. C., Marshall, A. G., & Cooper, W. T. (2003) · Analytical Chemistry · doi:10.1021/ac026106p · Cited by 641 · cited 2×
“FTICR is uniquely suited to analysis of complex natural organic mixtures, such as petroleum crude oil [9] and humic/fulvic acids [10].”
BackgroundSelf-citationKind, T., & Fiehn, O. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-234 · Cited by 637 · cited 1×
“Longer time-domain transient lifetime is needed for greater resolving power, to resolve isobaric species and to assign elemental composition at high m/z [15, 16].”
BackgroundThe role of electron capture dissociation in biomolecular analysis
Cooper, H. J., Håkansson, K., & Marshall, A. G. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20014 · Cited by 514 · cited 1×
“Accurate mass is essential for unambiguous identification of biological molecules, and their fragmentation can provide complete structural characterization and site(s) of posttranslational modification(s) [50].”
BackgroundSelf-citationSpace charge effects in Fourier transform mass spectrometry. II. Mass calibration
Ledford, E. B., Rempel, D. L., & Gross, M. L. (1984) · Analytical Chemistry · doi:10.1021/ac00278a027 · Cited by 468 · cited 1×
“The timedomain ICR signal is Hanning apodized, zero-filled once, and Fourier transformed to produce a magnitude-mode spectrum that is converted to a mass-to-charge ratio by a two term calibration equation [ 42 ].”
Method
Cited by
Organic coating on biochar explains its nutrient retention and stimulation of soil fertility
Hagemann, N., Joseph, S., Schmidt, H.-P., Kammann, C. I., Harter, J., Borch, T., Young, R. B., Varga, K., Taherymoosavi, S., Elliott, K. W., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01123-0 · Cited by 616
An ultrahigh‐resolution mass spectrometry index to estimate natural organic matter lability
D'Andrilli, J., Cooper, W. T., Foreman, C. M., & Marshall, A. G. (2015) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7400 · Cited by 515
Self-citation21 Tesla FT-ICR Mass Spectrometer for Ultrahigh-Resolution Analysis of Complex Organic Mixtures
Smith, D. F., Podgorski, D. C., Rodgers, R. P., Blakney, G. T., & Hendrickson, C. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04159 · Cited by 348
Self-citationA new conceptual framework for the transformation of groundwater dissolved organic matter
McDonough, L. K., Andersen, M. S., Behnke, M. I., Rutlidge, H., Oudone, P., Meredith, K., O’Carroll, D. M., Santos, I. R., Marjo, C. E., Spencer, R. G. M., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-29711-9 · Cited by 284
Predator data station: A fast data acquisition system for advanced FT-ICR MS experiments
Blakney, G. T., Hendrickson, C. L., & Marshall, A. G. (2011) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2011.03.009 · Cited by 261
Self-citationUse of mass spectrometry for imaging metabolites in plants
Lee, Y. J., Perdian, D. C., Song, Z., Yeung, E. S., & Nikolau, B. J. (2012) · The Plant Journal · doi:10.1111/j.1365-313x.2012.04899.x · Cited by 231
Bayat, H., Dehghanizadeh, M., Jarvis, J. M., Brewer, C. E., & Jena, U. (2021) · Frontiers in Sustainable Food Systems · doi:10.3389/fsufs.2021.658592 · Cited by 94
NeuCode Proteomics Reveals Bap1 Regulation of Metabolism
Baughman, J. M., Rose, C. M., Kolumam, G., Webster, J. D., Wilkerson, E. M., Merrill, A. E., Rhoads, T. W., Noubade, R., Katavolos, P., Lesch, J., et al. (2016) · Cell Reports · doi:10.1016/j.celrep.2016.05.096 · Cited by 73
Valeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Self-citationDang, X., Singh, A., Spetman, B. D., Nolan, K. D., Isaacs, J. S., Dennis, J. H., Dalton, S., Marshall, A. G., & Young, N. L. (2016) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00414 · Cited by 41
Self-citationFT-ICR MS analysis of blended pine-microalgae feedstock HTL biocrudes
Jarvis, J. M., Billing, J. M., Corilo, Y. E., Schmidt, A. J., Hallen, R. T., & Schaub, T. M. (2018) · Fuel · doi:10.1016/j.fuel.2017.12.016 · Cited by 40
Metadata
- Authors
- Kaiser, N. K., Quinn, J. P., Blakney, G. T., Hendrickson, C. L., & Marshall, A. G.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-05-05
- Volume
- 22
- Issue
- 8
- Pages
- 1343-1351
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2093381034
- Cited by
- 223
- References
- 44
- FWCI
- 8.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.