Identification of “Known Unknowns” Utilizing Accurate Mass Data and ChemSpider
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In many cases, an unknown to an investigator is actually known in the chemical literature, a reference database, or an internet resource. We refer to these types of compounds as "known unknowns." ChemSpider is a very valuable internet database of known compounds useful in the identification of these types of compounds in commercial, environmental, forensic, and natural product samples. The database contains over 26 million entries from hundreds of data sources and is provided as a free resource to the community. Accurate mass mass spectrometry data is used to query the database by either elemental composition or a monoisotopic mass. Searching by elemental composition is the preferred approach. However, it is often difficult to determine a unique elemental composition for compounds with molecular weights greater than 600 Da. In these cases, searching by the monoisotopic mass is advantageous. In either case, the search results are refined by sorting the number of references associated with each compound in descending order. This raises the most useful candidates to the top of the list for further evaluation. These approaches were shown to be successful in identifying "known unknowns" noted in our laboratory and for compounds of interest to others.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dalby, A., Nourse, J. G., Hounshell, W. D., Gushurst, A. K. I., Grier, D. L., Leland, B. A., & Laufer, J. (1992) · Journal of Chemical Information and Computer Sciences · doi:10.1021/ci00007a012 · Cited by 642
Hogenboom, A. C., van Leerdam, J. A., & de Voogt, P. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.053 · Cited by 263 · cited 1×
“A group of 90 compounds was assembled from literature sources [5–8], internet sites, and American Society of Mass Spectrometry Conference presentations to evaluate the two approaches in ChemSpider.”
BackgroundErve, J. C. L., Gu, M., Wang, Y., DeMaio, W., & Talaat, R. E. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.07.014 · Cited by 138
Hill, A. W., & Mortishire‐Smith, R. J. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2177 · Cited by 129
Little, J. L., Cleven, C. D., & Brown, S. D. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-010-0034-3 · Cited by 85 · cited 10×
“A very similar approach [1] was demonstrated to be very useful utilizing the CAS Registry of more than 62 million substances, a fee-based service, which is searched by either STN Express or the web-based version of SciFinder.”
BackgroundMethodResultSelf-citationGarcía-Reyes, J. F., Ferrer, I., Thurman, E. M., Molina‐Díaz, A., & Fernández-Alba, A. R. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2127 · Cited by 64 · cited 1×
“A group of 90 compounds was assembled from literature sources [5–8], internet sites, and American Society of Mass Spectrometry Conference presentations to evaluate the two approaches in ChemSpider.”
BackgroundLiao, W., Draper, W. M., & Perera, S. K. (2008) · Analytical Chemistry · doi:10.1021/ac801166z · Cited by 25 · cited 1×
“A group of 90 compounds was assembled from literature sources [5–8], internet sites, and American Society of Mass Spectrometry Conference presentations to evaluate the two approaches in ChemSpider.”
Background
Cited by
Wang, M., Carver, J. J., Phelan, V. V., Sanchez, L. M., Garg, N., Peng, Y., Nguyen, D. D., Watrous, J., Kapono, C. A., Luzzatto-Knaan, T., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3597 · Cited by 4,629
Global metabolic profiling of animal and human tissues via UPLC-MS
Want, E. J., Masson, P., Michopoulos, F., Wilson, I. D., Theodoridis, G., Plumb, R. S., Shockcor, J., Loftus, N., Holmes, E., & Nicholson, J. K. (2013) · Nature Protocols · doi:10.1038/nprot.2012.135 · Cited by 1,611
MetFrag relaunched: incorporating strategies beyond in silico fragmentation
Ruttkies, C., Schymanski, E. L., Wolf, S., Hollender, J., & Neumann, S. (2016) · Journal of Cheminformatics · doi:10.1186/s13321-016-0115-9 · Cited by 1,052
Schymanski, E. L., Singer, H. P., Slobodnik, J., Ipolyi, I. M., Oswald, P., Krauss, M., Schulze, T., Haglund, P., Letzel, T., Grosse, S., et al. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8681-7 · Cited by 703
Schymanski, E. L., Singer, H. P., Longrée, P., Loos, M., Ruff, M., Stravs, M. A., Ripollés Vidal, C., & Hollender, J. (2014) · Environmental Science & Technology · doi:10.1021/es4044374 · Cited by 414
Effect-directed analysis supporting monitoring of aquatic environments — An in-depth overview
Brack, W., Ait-Aissa, S., Burgess, R. M., Busch, W., Creusot, N., Di Paolo, C., Escher, B. I., Mark Hewitt, L., Hilscherova, K., Hollender, J., et al. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2015.11.102 · Cited by 413
High-confidence structural annotation of metabolites absent from spectral libraries
Hoffmann, M. A., Nothias, L.-F., Ludwig, M., Fleischauer, M., Gentry, E. C., Witting, M., Dorrestein, P. C., Dührkop, K., & Böcker, S. (2022) · Nature Biotechnology · doi:10.1038/s41587-021-01045-9 · Cited by 388
Gago-Ferrero, P., Schymanski, E. L., Bletsou, A. A., Aalizadeh, R., Hollender, J., & Thomaidis, N. S. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b03454 · Cited by 352
Bletsou, A. A., Jeon, J., Hollender, J., Archontaki, E., & Thomaidis, N. S. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.11.009 · Cited by 348
Mass Spectral Reference Libraries: An Ever-Expanding Resource for Chemical Identification
Stein, S. (2012) · Analytical Chemistry · doi:10.1021/ac301205z · Cited by 343
Prasse, C., Stalter, D., Schulte-Oehlmann, U., Oehlmann, J., & Ternes, T. A. (2015) · Water Research · doi:10.1016/j.watres.2015.09.023 · Cited by 319
Chemometric methods in data processing of mass spectrometry-based metabolomics: A review
Yi, L., Dong, N., Yun, Y., Deng, B., Ren, D., Liu, S., & Liang, Y. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.02.001 · Cited by 305
Integrating tools for non-targeted analysis research and chemical safety evaluations at the US EPA
Sobus, J. R., Wambaugh, J. F., Isaacs, K. K., Williams, A. J., McEachran, A. D., Richard, A. M., Grulke, C. M., Ulrich, E. M., Rager, J. E., Strynar, M. J., et al. (2018) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-017-0012-y · Cited by 215
“Initial work has determined that the Dashboard can effectively identify “known unknowns” in samples using data source ranking techniques as developed by Little et al [76].”
BackgroundSelf-citationLiquid chromatography-mass spectrometry for the determination of chemical contaminants in food
Hird, S. J., Lau, B. P.-Y., Schuhmacher, R., & Krska, R. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.04.005 · Cited by 203
“Assignment of a structure for a peak detected by accurate mass alone is unlikely, unless the compound detected has a significantmass defect between the monoisotopic mass of an element and the mass of its isotopic cluster [128,129] or is known in the chemical literature, a reference database or an Internet resource [13…”
BackgroundRager, J. E., Strynar, M. J., Liang, S., McMahen, R. L., Richard, A. M., Grulke, C. M., Wambaugh, J. F., Isaacs, K. K., Judson, R., Williams, A. J., et al. (2016) · Environment International · doi:10.1016/j.envint.2015.12.008 · Cited by 189
“It is noteworthy, however, that chemicals confirmed in the present study ranked highly against compounds with identical formulas in the ChemSpider inventory, after sorting by “# of Data Sources”, according to the method of Little et al. (2012) (results given in Supplementary Table 7).”
MethodSelf-citationSchröder, P., Helmreich, B., Škrbić, B., Carballa, M., Papa, M., Pastore, C., Emre, Z., Oehmen, A., Langenhoff, A., Molinos, M., et al. (2016) · Environmental Science and Pollution Research · doi:10.1007/s11356-016-6503-x · Cited by 184
Metabolomics technology and bioinformatics for precision medicine
Azad, R. K., & Shulaev, V. (2019) · Briefings in Bioinformatics · doi:10.1093/bib/bbx170 · Cited by 180
Metadata
- Authors
- Little, J. L., Williams, A. J., Pshenichnov, A., & Tkachenko, V.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-11-02
- Volume
- 23
- Issue
- 1
- Pages
- 179-185
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1986517195
- Cited by
- 168
- References
- 7
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.