Epidermal Differential Impedance Sensor for Conformal Skin Hydration Monitoring
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We present the design and use of an ultrathin, stretchable sensor system capable of conformal lamination onto the skin, for precision measurement and spatial mapping of levels of hydration. This device, which we refer to as a class of ‘epidermal electronics’ due to its ‘skin-like’ construction and mode of intimate integration with the body, contains miniaturized arrays of impedance-measurement electrodes arranged in a differential configuration to compensate for common-mode disturbances. Experimental results obtained with different frequencies and sensor geometries demonstrate excellent precision and accuracy, as benchmarked against conventional, commercial devices. The reversible, non-invasive soft contact of this device with the skin makes its operation appealing for applications ranging from skin care, to athletic monitoring to health/wellness assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationSkin hydration: A review on its molecular mechanisms
Verdier‐Sévrain, S., & Bonté, F. (2007) · Journal of Cosmetic Dermatology · doi:10.1111/j.1473-2165.2007.00300.x · Cited by 605
Biomechanical Properties of In Vivo Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470
KLEINER, S. M. (1999) · Journal of the American Dietetic Association · doi:10.1016/s0002-8223(99)00048-6 · Cited by 333
Cited by
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
“amplitude of the signal and shift its resonant frequency.(22)”
BackgroundSelf-citationBio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citationWearable multifunctional sensors using printed stretchable conductors made of silver nanowires
Yao, S., & Zhu, Y. (2014) · Nanoscale · doi:10.1039/c3nr05496a · Cited by 1,028
Recent Progress in Materials and Devices toward Printable and Flexible Sensors
Rim, Y. S., Bae, S., Chen, H., De Marco, N., & Yang, Y. (2016) · Advanced Materials · doi:10.1002/adma.201505118 · Cited by 771
Metadata
- Authors
- Huang, X., Yeo, W.-H., Liu, Y., & Rogers, J. A.
- Venue
- Biointerphases
- Publisher
- American Vacuum Society
- Published
- 2012-08-23
- Volume
- 7
- Issue
- 1
- Pages
- 52-52
- ISSN
- 1559-4106 (ISSN-L)
- 1934-8630
- OpenAlex
- W2085834391
- Cited by
- 144
- References
- 4
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Epidermal Differential Impedance Sensor for Conformal Skin Hydration Monitoring. https://app.cochat.ai/papers/10.1007/s13758-012-0052-8
- The paper
- Huang, X., Yeo, W.-H., Liu, Y., & Rogers, J. A. (2012). Epidermal Differential Impedance Sensor for Conformal Skin Hydration Monitoring. Biointerphases. https://doi.org/10.1007/s13758-012-0052-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.