CoChat

An Examination and Critique of Current Methods to Determine Exercise Intensity

Open access

The DOI matches its Crossref record; 250 of the 253 references it cites were found in a registry or an index.

Abstract

Prescribing the frequency, duration, or volume of training is simple as these factors can be altered by manipulating the number of exercise sessions per week, the duration of each session, or the total work performed in a given time frame (e.g., per week). However, prescribing exercise intensity is complex and controversy exists regarding the reliability and validity of the methods used to determine and prescribe intensity. This controversy arises from the absence of an agreed framework for assessing the construct validity of different methods used to determine exercise intensity. In this review, we have evaluated the construct validity of different methods for prescribing exercise intensity based on their ability to provoke homeostatic disturbances (e.g., changes in oxygen uptake kinetics and blood lactate) consistent with the moderate, heavy, and severe domains of exercise. Methods for prescribing exercise intensity include a percentage of anchor measurements, such as maximal oxygen uptake ([Formula: see text]), peak oxygen uptake ([Formula: see text]), maximum heart rate (HR max ), and maximum work rate (i.e., power or velocity-[Formula: see text] or [Formula: see text], respectively), derived from a graded exercise test (GXT). However, despite their common use, it is apparent that prescribing exercise intensity based on a fixed percentage of these maximal anchors has little merit for eliciting distinct or domain-specific homeostatic perturbations. Some have advocated usin…

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s40279-020-01322-8

Cites

250 of 250 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 250 references

Research works printed but not linked: 3

  1. S Seiler, E Tønnessen, Sportscience sportsci. org. Sportscience. 13Seiler S, Tønnessen E. Sportscience sportsci. org. Sportscience. 2009;13:32-533.
  2. Muscle metabolic and neuromuscular determinants of fatigue during cycling in different exercise intensity domains. M I Black, A M Jones, J R Blackwell, S J Bailey, L J Wylie, S T Mcdonagh, J Appl Physiol. 1223Black MI, Jones AM, Blackwell JR, Bailey SJ, Wylie LJ, McDon- agh ST, et al. Muscle metabolic and neuromuscular determinants of fatigue during cycling in different exercise intensity domains. J Appl Physiol. 2016;122(3):446-59. · DOI · Paper page
  3. The slow component of VO2 kinetics: mechanistic bases and practical applications: Healthy Learning. A M Jones, D C Poole, B Grassi, P M Christensen, Jones AM, Poole DC, Grassi B, Christensen PM. The slow com- ponent of VO2 kinetics: mechanistic bases and practical applica- tions: Healthy Learning; 2010. · DOI · Paper page

Cited by

Items 201–300 of 488

Metadata

Authors
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J.
Affiliations
  • Victoria University (AU)
  • Rocky Mountain University of Health Professions (US)
  • Monash University (AU)
  • University of Canberra (AU)
Corresponding author
Jamnick, Nicholas A.
Venue
Sports Medicine
Published
2020-07-30
Volume
50
Issue
10
Pages
1729-1756
ISSN
  • 0112-1642 (ISSN-L)
  • 1179-2035
OpenAlex
W3046341008
Cited by
424
References
253
Citations by year
2026: 64 · 2025: 105 · 2024: 87 · 2023: 55 · 2022: 55 · 2021: 53 · 2020: 4
FWCI
8.65
Type
journal article
Language
en
Open access
Licence
Locations
  • Sports Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Victoria University Research Repository (Victoria University) (submittedVersion)
  • Deakin Research Online (Deakin University) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
Keywords
exercise intensity prescription, construct validity, oxygen uptake kinetics, blood lactate, ventilatory threshold, gas exchange threshold, respiratory compensation point, lactate threshold, maximal lactate steady state, critical power, critical speed, VO2max, heart rate, incremental exercise test
MeSH terms
Exercise Test, Heart Rate, Humans, Oxygen Consumption, Reproducibility of Results, Anaerobic Threshold, Exercise, Lactic Acid, Athletic Performance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.