Cited by 90Electrolyte and hormonal disordersNeuroendocrine regulation and behaviorCardiovascular, Neuropeptides, and Oxidative Stress Research

Vasopressin, its bioassay and the physiological control of its release

Share, Leonard·1967·The American Journal of Medicine

Integrity signals

Registry

Crossref · 10.1016/0002-9343(67)90090-3

Cites

72 of 72 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The normal plasma concentration of vasopressin in man is below 2 μU/ml (5 pg/ml), increasing several fold after 24 h of dehydration.

    “the normal plasma concentration of vasopressin in man is below 2 μU/ml (5 pg/ml) 39, with this increasing several fold after 24 h of dehydration.”

Cites

Flagged first, then by citations

3 of the 75 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Share, L.
Corresponding author
Share, Leonard
Venue
The American Journal of Medicine
Publisher
Elsevier BV
Published
1967-05
Volume
42
Issue
5
Pages
701-712
ISSN
0002-9343 (ISSN-L)
OpenAlex
W1971369703
Cited by
90
References
75
Citations by year
2020: 1 · 2017: 1 · 2016: 1
FWCI
2.50
Type
journal article
Language
en
Open access
closed
Locations
  • The American Journal of Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Electrolyte and hormonal disorders
  • Social Sciences › Psychology › Social Psychology › Neuroendocrine regulation and behavior
  • Health Sciences › Medicine › Surgery › Cardiovascular, Neuropeptides, and Oxidative Stress Research
Keywords
vasopressin, bioassay, hormone release regulation, neurosecretion
MeSH terms
Biological Assay, Vasopressins

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review