Phagocytic and metabolic reactions to chronically implanted metal brain electrodes.
Abstract
In order to study the biocompatibility of metal electrodes and insulations in the rat brain, eight different metal electrode types and two different insulations were implanted for 11, 35, 36, 37, or 63 days. Stainless steel and Nichrome were nontoxic metals, silver was toxic, and copper extremely toxic with phagocytosis active to 37 days of implantation. Active phagocytosis was easily detected by high glucose demand using 2-deoxy[14C]glucose (2-DG) autoradiography contrasted with normal 2-DG autoradiographs where phagocytes were present but not ingesting. Epoxylite, an epoxy-polyester varnish, was slightly more reactive in brain than polyimide but not statistically significant. In general, larger electrodes created more tissue reaction per se for as long as 37 days. These results suggested that a thin stainless-steel bipolar electrode will provide safe recording electrodes in either animal or human brain. The importance of these findings is that certain metals (silver, copper) cannot be used in the brain without producing necrosis and phagocytosis, whereas other metals (stainless steel, Nichrome) with varnish insulators (Epoxylite, polyimide) can be implanted without producing any detectable damage beyond that of the initial trauma and brief phagocytosis limited to the edge of the electrode track. Finally, the glucose metabolism autoradiographs differentiated active phagocytosis (copper) from inactive phagocytes (silver) when using long implants (37 days) of toxic metals.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Neural electrodes can be implanted without producing any detectable damage beyond the initial trauma and brief phagocytosis, typically limited to the edges of the electrode insertion pathway.
“Neural electrodes can be implanted without producing any detectable damage beyond the initial trauma and brief phagocytosis, which are typically limited to the edges of the electrode insertion pathway (Babb and Kupfer, 1984) (Freitas, 2003).”
From Human Brain/Cloud Interface (2019) · cites this paper as Babb and Kupfer, 1984
Cites
Sokoloff, L., Reivich, M., Kennedy, C., Rosiers, M. H. D., Patlak, C. S., Pettigrew, K. D., Sakurada, O., & Shinohara, M. (1977) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1977.tb10649.x · Cited by 6,000 · see citing works
The Biochemical Basis of Phagocytosis
Sbarra, A. J., & Karnovsky, M. L. (1959) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)70011-2 · Cited by 1,256 · see citing works
Electrical Stimulation of the Brain
J.L.D. (1962) · Neurology · doi:10.1212/wnl.12.8.582 · Cited by 439 · see citing works
Clinical Applications of Studies on Stereotactically Implanted Electrodes in Temporal-Lobe Epilepsy
Crandall, P. H., WALTER, R. D., & Rand, R. W. (1963) · Journal of neurosurgery · doi:10.3171/jns.1963.20.10.0827 · Cited by 221 · see citing works
Analysis of extracellular firing patterns of deep temporal lobe structures in man
Babb, T. L., Carr, E. M., & Crandall, P. H. (1973) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(73)90252-6 · Cited by 175 · see citing works
Self-citationBrain tissue reaction to some chronically implanted metals
Dymond, A. M., Le, K., Jurist, J. M., & Crandall, P. H. (1970) · Journal of neurosurgery · doi:10.3171/jns.1970.33.5.0574 · Cited by 140 · see citing works
Complex sensory properties of certain amygdala units in the freely moving cat
O'Keefe, J. M., & Bouma, H. (1969) · Experimental Neurology · doi:10.1016/0014-4886(69)90086-7 · Cited by 139 · see citing works
Spontaneous activity of cat hippocampal neurons in sleep and wakefulness
Noda, H., Manohar, S., & ADEY, W. R. (1969) · Experimental Neurology · doi:10.1016/0014-4886(69)90016-8 · Cited by 102 · see citing works
Intraperitoneal administration and other modifications of the 2-deoxy-d-glucose technique
Meibach, R. C., Glick, S. D., Ross, D. A., Cox, R. D., & Maayani, S. (1980) · Brain Research · doi:10.1016/0006-8993(80)90874-4 · Cited by 92 · see citing works
Histopathological Changes Produced by Implanted Electrodes in Cat Brains
Collias, J. C., & Manuelidis, E. E. (1957) · Journal of neurosurgery · doi:10.3171/jns.1957.14.3.0302 · Cited by 68 · see citing works
Evaluation of permanent implantation of electrodes within the brain
Delgado, J. R. (1955) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(55)90091-2 · Cited by 68 · see citing works
Government, Medicine and the Common Weal
Woodhall, B. (1964) · Journal of neurosurgery · doi:10.3171/jns.1964.21.10.0827 · Cited by 45 · see citing works
Histopathological studies of tissue reactions to various metals implanted in cat brains.
Robinson, F. R., & Johnson, M. T. (1961) · PubMed · Cited by 41 · see citing works
Depth recording from the human brain in epilepsy
Fischer-Williams, M., & Cooper, R. (1963) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(63)90030-0 · Cited by 33 · see citing works
Toxic effects of intra-cerebral electrodes
Cooper, R., & CROW, H. J. (1966) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474827 · Cited by 30 · see citing works
Bickford, R. G., Uihlein, A., & Petersen, M. C. (1953) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(26)02288-3 · Cited by 15 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · see citing works
Criteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240 · see citing works
Functional connections in the human temporal lobe
Wilson, C. L., Isokawa, M., Babb, T. L., & Crandall, P. H. (1990) · Experimental Brain Research · doi:10.1007/bf00231248 · Cited by 235 · see citing works
Self-citationToxicological Aspects of Topical Silver Pharmaceuticals
Hollinger, M. A. (1996) · Critical Reviews in Toxicology · doi:10.3109/10408449609012524 · Cited by 208 · see citing works
Biocompatibility of silicon‐based electrode arrays implanted in feline cortical tissue
Schmidt, S., Horch, K., & Normann, R. A. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271106 · Cited by 182 · see citing works
A review of electrodes for the electrical brain signal recording
Im, C., & Seo, J.-M. (2016) · Biomedical Engineering Letters · doi:10.1007/s13534-016-0235-1 · Cited by 141 · see citing works
Biological Reactions to Cerebrospinal Fluid Shunt Devices: A Review of the Cellular Pathology
Bigio, M. R. D. (1998) · Neurosurgery · doi:10.1097/00006123-199802000-00064 · Cited by 106 · see citing works
Dissolution of dense carbonate apatite subcutaneously implanted in Wistar rats
Barralet, J. E., Akao, M., Aoki, H., & Aoki, H. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(200002)49:2 · Cited by 97 · see citing works
Martins, N. R. B., Angelica, A., Chakravarthy, K., Svidinenko, Y., Boehm, F. J., Opris, I., Lebedev, M. A., Swan, M., Garan, S. A., Rosenfeld, J. V., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00112 · Cited by 91 · see citing works
Sun, Y.-S., Peng, S.-W., & Cheng, J. (2012) · Biomicrofluidics · doi:10.1063/1.4750486 · Cited by 75 · see citing works
Modelling traumatic brain injury and posttraumatic epilepsy in rodents
Brady, R. D., Casillas-Espinosa, P. M., Agoston, D. V., Bertram, E. H., Kamnaksh, A., Semple, B. D., & Shultz, S. R. (2018) · Neurobiology of Disease · doi:10.1016/j.nbd.2018.08.007 · Cited by 68 · see citing works
Imaninezhad, M., Pemberton, K., Xu, F., Kalinowski, K., Bera, R., & Zustiak, S. P. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aad65b · Cited by 62 · see citing works
Does prolonged implantation of depth electrodes predispose the brain to kindling?
Löscher, W., Wahnschaffe, U., Hönack, D., & Rundfeldt, C. (1995) · Brain Research · doi:10.1016/0006-8993(95)00843-f · Cited by 58 · see citing works
The Electrochemistry of Charge Injection at the Electrode/Tissue Interface
Merrill, D. R. (2010) · Biological and medical physics series · doi:10.1007/978-0-387-98120-8_4 · Cited by 54 · see citing works
Nanostructured Coatings for Improved Charge Delivery to Neurons
Kozai, T. D. Y., Alba, N. A., Zhang, H., Kotov, N. A., Gaunt, R. A., & Cui, X. T. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_4 · Cited by 42 · see citing works
Kim, T., Branner, A., Gulati, T., & Giszter, S. F. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045001 · Cited by 39 · see citing works
Kendırlı, M. T., Rose, D. T., & Bertram, E. H. (2014) · Epilepsia · doi:10.1111/epi.12854 · Cited by 31 · see citing works
EEG Monitoring during Functional MRI in Animal Models
Mirsattari, S. M., Ives, J. R., Leung, L.-W. S., & Menon, R. S. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01240.x · Cited by 30 · see citing works
Soft peripheral nerve interface made from carbon nanotubes embedded in silicone
Terkan, K., Zurita, F., Khalaf, T. J., Rinklin, P., Teshima, T., Kohl, T., & Wolfrum, B. L. (2020) · APL Materials · doi:10.1063/5.0021887 · Cited by 26 · see citing works
In Vivo Penetrating Microelectrodes for Brain Electrophysiology
Erofeev, A., Antifeev, I., Bolshakova, A. V., Борисович, Б. И., & Власова, О. Л. (2022) · Sensors · doi:10.3390/s22239085 · Cited by 24 · see citing works
Jia, W., Song, Y., Yang, L., Kong, J., Boczek, T., He, Z., Wang, Y., Zhang, X., Hu, H., Shao, D., et al. (2020) · Expert Review of Clinical Pharmacology · doi:10.1080/17512433.2020.1816821 · Cited by 23 · see citing works
Retarded kindling progression in mice deficient in the extracellular matrix glycoprotein tenascin‐R
Hoffmann, K., Sivukhina, E. V., Potschka, H., Schachner, M., Löscher, W., & Dityatev, A. E. (2009) · Epilepsia · doi:10.1111/j.1528-1167.2008.01774.x · Cited by 23 · see citing works
Phagocytic and metabolic reactions to intracerebral electrical stimulation of rat brain
Babb, T. L., & Kupfer, W. R. (1984) · Experimental Neurology · doi:10.1016/0014-4886(84)90180-8 · Cited by 21 · see citing works
Self-citationDistribution, metabolism, excretion, and toxicity of implanted silver: a review
Hadrup, N., Sharma, A. K., Jacobsen, N. R., & Loeschner, K. (2021) · Drug and Chemical Toxicology · doi:10.1080/01480545.2021.1950167 · Cited by 19 · see citing works
Yi, D., Yao, Y., Wang, Y., & Chen, L. (2024) · Journal of Manufacturing Processes · doi:10.1016/j.jmapro.2024.07.100 · Cited by 19 · see citing works
INTRACRANIAL ELECTROPHYSIOLOGIC STUDIES
Risinger, M. W., & Gumnit, R. J. (1995) · Neuroimaging Clinics of North America · doi:10.1016/s1052-5149(25)00324-7 · Cited by 19 · see citing works
Właź, P., Ebert, U., Potschka, H., & Löscher, W. (1998) · European Journal of Pharmacology · doi:10.1016/s0014-2999(98)00409-9 · Cited by 14 · see citing works
Raffa, V., Pensabene, V., Menciassi, A., & Dario, P. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9042-2 · Cited by 13 · see citing works
Yang, J., Charif, A. C., Puskas, J. E., Phillips, H., Shanahan, K. J., Garsed, J., Fleischman, A. J., Goldman, K., Roy, S., Luebbers, M. T., et al. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.01.018 · Cited by 11 · see citing works
Kamat, A. A., Paskaranandavadivel, N., Alighaleh, S., Cheng, L. K., & Angeli, T. R. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02457-5 · Cited by 9 · see citing works
The Electrode – Materials and Configurations
Merrill, D. R. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-381409-8.00006-1 · Cited by 9 · see citing works
Targeting the lateral but not the third ventricle induces bone loss in ewe
Oheim, R., Beil, F. T., Barvencik, F., Egermann, M., Amling, M., Clarke, I. J., & Pogoda, P. (2012) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e318238b3bd · Cited by 9 · see citing works
Electrodes and instrumentation for neurostimulation
Merrill, D. R. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00002-2 · Cited by 8 · see citing works
Tresco, P. A., & Gerhardt, G. A. (2008) · Springer eBooks · doi:10.1007/978-1-4020-8705-9_3 · Cited by 8 · see citing works
Single-pulse electrical stimulation methodology in freely moving rat
Gronlier, E., Vendramini, E., Volle, J., Woźniak-Kwaśniewska, A., Santos, N. A., Coizet, V., Duveau, V., & Olivier David, A. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109092 · Cited by 7 · see citing works
Linear Intracerebral Calcification After Depth Electrode Implantation
Blatt, I., Johnson, D. W., Dasheiff, R. M., & Vries, J. K. (1995) · Epilepsia · doi:10.1111/j.1528-1157.1995.tb00493.x · Cited by 7 · see citing works
Manufacture and use of fused silica cannulas for intracerebral injections in freely moving rats
Berger, M. L., Reither, H., Schmid, R. W., & Lassmann, H. (1989) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(89)90084-8 · Cited by 6 · see citing works
Kim, T., Zhong, Y., & Giszter, S. F. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2911912 · Cited by 5 · see citing works
Vigilance‐Controlled Quantified EEG in Safety Pharmacology
Dürmüller, N., Porsolt, R. D., & Scherschlicht, R. (2000) · Current Protocols in Pharmacology · doi:10.1002/0471141755.ph1006s11 · Cited by 4 · see citing works
Biocompatibility of wire electrodes improved by MPC polymer coating
Taniguchi, N., Suzuki, T., & Mabuchi, K. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369627 · Cited by 3 · see citing works
Whitehead, K. A., Mohtadi, M. E., Slate, A. J., Vaidya, M., & Wilson-Nieuwenhuis, J. S. T. (2021) · Royal Society of Chemistry eBooks · doi:10.1039/9781788019828-00231 · Cited by 3 · see citing works
The electrode—principles of the neural interface and materials
Merrill, D. R., & Stecker, M. M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-817000-7.00007-7 · Cited by 3 · see citing works
Ellens, D. J., & Blumenfeld, H. (2009) · Springer eBooks · doi:10.1007/978-3-540-87919-0_24
A REVIEW OF THE HEALTH EFFECTS
Cross, H., Beach, J. R., Levy, L. S., Sadhra, S. S., Sorahan, T., McRoy, C., & Birmingham, B. C. (1999)
Kindling Rates in Sprague Dawley Rats as a Function of Copper and Nichrome Electrodes
Wolske, M. B., Lian, E. H. C., & Leech, C. K. (1986) · Proceedings of the Indiana Academy of Science
Invasive EEG in Mesial Temporal Epilepsy
Ross, J., Cosgrove, G. R., & Cole, A. J. (1999) · Elsevier eBooks · doi:10.1016/b978-012422150-5/50026-3
Gummadavelli, A., Sanganahalli, B. G., Hermán, P., Hyder, F., & Blumenfeld, H. (2022) · Springer eBooks · doi:10.1007/978-3-031-07121-8_27
Ouardouz, M., Hernan, A. E., Mahoney, J. M., & Scott, R. C. (2026) · iScience · doi:10.1016/j.isci.2026.115066
Mazurkiewicz, W., Linfield, S., Wójtowicz, T., Koprowska, J., & Nery, E. W. (2026) · Electrochimica Acta · doi:10.1016/j.electacta.2026.149002
- Authors
- Babb, T. L., & Kupfer, W.
- Affiliations
- University of California, Los Angeles (US)
- Venue
- Experimental Neurology
- Publisher
- Elsevier BV
- Published
- 1984-11
- Volume
- 86
- Issue
- 2
- Pages
- 171-182
- ISSN
- 0014-4886 (ISSN-L)
- OpenAlex
- W1977864921
- Cited by
- 51
- References
- 16
- Citations by year
- 2026: 2 · 2024: 1 · 2022: 3 · 2021: 4 · 2020: 3 · 2019: 2 · 2018: 2 · 2016: 1 · 2015: 1 · 2014: 2 · 2013: 1 · 2012: 3
- FWCI
- 0.28
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Experimental Neurology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Neurology › Neurological disorders and treatments
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- neural implants, metal electrodes, biocompatibility, phagocytosis, tissue reaction, stainless steel, nickel-chromium alloy, silver toxicity, copper toxicity, electrode insulation, polyimide, 2-deoxyglucose autoradiography, glucose metabolism, chronic implantation
- MeSH terms
- Animals, Autoradiography, Brain, Deoxyglucose, Electrodes, Implanted, Epoxy Resins, Male, Metals, Phagocytosis, Resins, Synthetic, Time Factors, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review