Quantitation of articular surface topography and cartilage thickness in knee joints using stereophotogrammetry
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
An analytical stereophotogrammetry (SPG) technique has been developed based upon some of the pioneering work of Selvik [Ph.D. thesis, University of Lund, Sweden (1974)] and Huiskes and co-workers [J. Biomechanics18, 559–570 (1985)], and represents a fundamental step in the construction of biomechanical models of diarthrodial joints. Using this technique, the precise three-dimensional topography of the cartilage surfaces of various diarthrodial joints has been obtained. The system presented in this paper delivers an accuracy of 90 μm in the least favorable conditions with 95% coverage using the same calibration method as Huiskes et al. (1985). In addition, a method has been developed, using SPG, to quantitatively map the cartilage thickness over the entire articular surface of a joint with a precision of 134 μm (95% coverage). In the present study, our SPG system has been used to quantify the topography, including surface area, of the articular surfaces of the patella, distal femur, tibial plateau, and menisci of the human knee. Furthermore, examples of cartilage thickness maps and corresponding thickness data including coefficient of variation, minimum, maximum, and mean cartilage thickness are also provided for the cartilage surfaces of the knee. These maps illustrate significant variations over the joint surfaces which are important in the determination of the stresses and strains within the cartilage during diarthrodial joint function. In addition, these cartilage surface topographies and thickness data are essential for the development of anatomically accurate finite element models of diarthrodial joints. The geometric data obtained in this study may also be useful for other bioengineering applications such as the determination of joint contact areas [Ateshian et al., ASME Biomech. Symp.98, 105–108 (1989); Soslowsky et al., ASME Adv. Bioengng15, 129–130 (1989); Soslowsky et al., Biomechanics of Diarthrodial Joints, pp. 243–268. Springer, NY (1990)] and the development of anatomically accurate artificial joints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Self-citationMortenson, M. E. (1985) · Cited by 1,475
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
Abernethy, R. B., Benedict, R. P., & Dowdell, R. B. (1985) · Journal of Fluids Engineering · doi:10.1115/1.3242450 · Cited by 809
Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
Rigid body motion calculated from spatial co-ordinates of markers
Spoor, C. W., & Veldpaus, F. E. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90020-2 · Cited by 579
A three-dimensional mathematical model of the knee-joint
Wismans, J., Veldpaus, F., Janssen, J., Huson, A., & Struben, P. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90354-1 · Cited by 351
Biomechanics of Diarthrodial Joints: Volume I
(1990) · Springer eBooks · doi:10.1007/978-1-4612-3448-7 · Cited by 267
Ahmed, A. M., Burke, D. L., & Yu, A. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138410 · Cited by 225
Hou, J. S., Holmes, M. H., Lai, W. M., & Mow, V. C. (1989) · Journal of Biomechanical Engineering · doi:10.1115/1.3168343 · Cited by 215
Self-citation
Cited by
A Framework for the in Vivo Pathomechanics of Osteoarthritis at the Knee
Andriacchi, T. P., Mündermann, A., Smith, R. L., Alexander, E. J., Dyrby, C. O., & Koo, S. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000017541.82498.37 · Cited by 1,062
Cartilage and diarthrodial joints as paradigms for hierarchical materials and structures
Mow, V. C., Ratcliffe, A., & Robin Poole, A. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90001-5 · Cited by 956
Self-citationA Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact
Haut Donahue, T. L., Hull, M. L., Rashid, M. M., & Jacobs, C. R. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1470171 · Cited by 493
Mechano-Electrochemical Properties Of Articular Cartilage: Their Inhomogeneities and Anisotropies
Mow, V. C., & Guo, X. E. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.110701.120309 · Cited by 478
Self-citationSong, E.-K., Seon, J.-K., Yim, J.-H., Netravali, N. A., & Bargar, W. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2407-3 · Cited by 447
Eckstein, F., Cicuttini, F., Raynauld, J.-P., Waterton, J. C., & Peterfy, C. (2006) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2006.02.026 · Cited by 418
Excursion of the Rotator Cuff Under the Acromion: Patterns of Subacromial Contact
Flatow, E. L., Soslowsky, L. J., Ticker, J. B., Pawluk, R. J., Hepler, M., Ark, J., Mow, V. C., & Bigliani, L. U. (1994) · The American Journal of Sports Medicine · doi:10.1177/036354659402200609 · Cited by 371
Self-citationCohen, Z. A., McCarthy, D. M., Kwak, S. D., Legrand, P., Fogarasi, F., Ciaccio, E. J., & Ateshian, G. A. (1999) · Osteoarthritis and Cartilage · doi:10.1053/joca.1998.0165 · Cited by 353
Self-citationQuantitative MRI of cartilage and bone: degenerative changes in osteoarthritis
Eckstein, F., Burstein, D., & Link, T. M. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1063 · Cited by 343
Muscle and Joint Function in Human Locomotion
Pandy, M. G., & Andriacchi, T. P. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105259 · Cited by 325
Bryant, S. J., & Anseth, K. S. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00225-8 · Cited by 310
The effects of exercise on human articular cartilage
Eckstein, F., Hudelmaier, M., & Putz, R. (2006) · Journal of Anatomy · doi:10.1111/j.1469-7580.2006.00546.x · Cited by 300
The influence of structural design of PLGA/collagen hybrid scaffolds in cartilage tissue engineering
Dai, W., Kawazoe, N., Lin, X., Dong, J., & Chen, G. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.070 · Cited by 248
Setton, L. A., Mow, V. C., Müller, F. J., Pita, J. C., & Howell, D. S. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120402 · Cited by 227
Self-citationAnatomically shaped osteochondral constructs for articular cartilage repair
Hung, C. T., Lima, E. G., Mauck, R. L., Taki, E., LeRoux, M. A., Lu, H. H., Stark, R. G., Guo, X. E., & Ateshian, G. A. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00213-6 · Cited by 215
“For clinical applications, the anatomic shape of the scaffold may be based on data obtained through imaging of the patient’s healthy contralateral joint surfaces, mirroring and optionally modifying it to provide a more functional, patient-specific surface topography (Ateshian et al., 1991; Cohen et al., 1999).”
BackgroundMethodSelf-citationMechano-regulation of stem cell differentiation and tissue regeneration in osteochondral defects
Kelly, D. J., & Prendergast, P. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.06.026 · Cited by 204
In vivo tibiofemoral contact analysis using 3D MRI-based knee models
DeFrate, L. E., Sun, H., Gill, T. J., Rubash, H. E., & Li, G. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.01.012 · Cited by 188
Li, G., Park, S. E., DeFrate, L. E., Schutzer, M. E., Ji, L., Gill, T. J., & Rubash, H. E. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.04.001 · Cited by 182
“(Ateshian et al., 1991).”
Chen, G., Sato, T., Ushida, T., Hirochika, R., Shirasaki, Y., Ochiai, N., & Tateishi, T. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10164 · Cited by 176
Froimson, M. I., Ratcliffe, A., Gardner, T. R., & Mow, V. C. (1997) · Osteoarthritis and Cartilage · doi:10.1016/s1063-4584(97)80042-8 · Cited by 163
Self-citationDonzelli, P. S., Spilker, R. L., Ateshian, G. A., & Mow, V. C. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00106-2 · Cited by 160
“Linear, isotropic, biphasic models of cartilage predict that peak stresses in the tissue occur at the cartilage}bone interface, away from the center of contact of the articular surfaces (Ateshian et al., 1991; Ateshian et al., 1994; Ateshian and Wang, 1995; Donzelli and Spilker, 1998), and are in excellent agreement w…”
BackgroundSelf-citationAteshian, G. A., Rosenwasser, M. P., & Mow, V. C. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90102-7 · Cited by 159
Self-citation
Metadata
- Authors
- Ateshian, G. A., Soslowsky, L. J., & Mow, V. C.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1991
- Volume
- 24
- Issue
- 8
- Pages
- 761-776
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2061147834
- Cited by
- 276
- References
- 17
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.