The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus
Abstract
The conflicting conclusions regarding the relationship between the tensile and compressive strengths of trabecular bone remain unexplained. To help resolve this issue, we compared measurements of the tensile (n = 22) and compressive (n = 22) yield strengths, and yield strains, of trabecular bone specimens taken from 38 bovine proximal tibiae. We also studied how these failure properties depended on modulus and apparent density. To enhance accuracy, trabecular orientation was controlled, and each specimen had a reduced section where strains were measured with a miniature extensometer. We found that the mean yield strength was 30% lower for tensile loading. However, the difference between individual values of the tensile and compressive strengths increased linearly with increasing modulus and density, being negligible for low moduli, but substantial for high moduli. By contrast, both the tensile and compressive yield strains were independent of modulus and density, with the yield strain being 30% lower for tensile loading. Thus, the difference between the tensile and compressive strengths of bovine tibial trabecular bone depends on the modulus, but the difference between yield strains does not. This phenomenon may explain in part that conflicting conclusions reached previously on the tensile and compressive strengths of trabecular bone since the mean modulus has varied among different studies. Realizing that our data pertain only directly to bovine tibial trabecular bone for longitudinal loading, our results nevertheless suggest that failure parameters based on strains may provide more powerful and general comparisons of the failure properties for trabecular bone than measures based on stress.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“As with cortical bone, the strength of trabecular bone is greater in compression than tension, and is lowest in shear, although these differences decrease with decreasing apparent density (78).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [78]
In the citing paper
“As with cortical bone, the strength of trabecular bone is greater in compression than tension, and is lowest in shear, although these differences decrease with decreasing apparent density (78).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [78]
In the citing paper
“As with cortical bone, the strength of trabecular bone is greater in compression than tension, and is lowest in shear, although these differences decrease with decreasing apparent density (78).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [78]
Citations
Cites
A General Theory of Strength for Anisotropic Materials
Tsai, S. W., & Wu, E. M. (1971) · Journal of Composite Materials · doi:10.1177/002199837100500106 · Cited by 3,401
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Self-citationThe elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
Mosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401
Contribution of collagen and mineral to the elastic-plastic properties of bone
Burstein, A. H., Zika, J. M., Heiple, K. G., & Klein, L. (1975) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197557070-00013 · Cited by 391
Fracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895412 · Cited by 313
Self-citationThe Various Stress Patterns of Press-Fit, Ingrown, and Cemented Femoral Stems
Huiskes, R. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199012000-00006 · Cited by 313
Physical properties of trabecular bone
Galante, J. O., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue International · doi:10.1007/bf02017552 · Cited by 302
Cited by
Sorted by citations
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142
Self-citationBone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Basic material properties—As with cortical bone, the strength of trabecular bone is greater in compression than tension, and is lowest in shear, although these differences decrease with decreasing apparent density (78).”
Biomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 807
Self-citationDependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Self-citationPrediction of femoral fracture load using automated finite element modeling
Keyak, J. H., Rossi, S. A., Jones, K. A., & Skinner, H. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00123-1 · Cited by 684
Yield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 654
Self-citationMathematical relationships between bone density and mechanical properties: A literature review
Helgason, B., Perilli, E., Schileo, E., Taddei, F., Brynjólfsson, S., & Viceconti, M. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.024 · Cited by 591
Biomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez‐Viloria, M., Villa‐Camacho, J. C., Vaziri, A., & Nazarian, A. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 616
Crawford, R. P., Cann, C. E., & Keaveny, T. M. (2003) · Bone · doi:10.1016/s8756-3282(03)00210-2 · Cited by 549
Self-citationModelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
Niebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 430
Self-citationPrediction of strength and strain of the proximal femur by a CT-based finite element method
Bessho, M., Ohnishi, I., Matsuyama, J., Matsumoto, T., Imai, K., & Nakamura, K. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.08.003 · Cited by 408
Systematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100150115 · Cited by 377
Self-citationRationally designed meta-implants: a combination of auxetic and conventional meta-biomaterials
Kolken, H. M. A., Janbaz, S., Leeflang, M. A., Lietaert, K., Weinans, H., & ZADPOOR, A. A. (2017) · Materials Horizons · doi:10.1039/c7mh00699c · Cited by 375
Biomechanical considerations of animal models used in tissue engineering of bone
Liebschner, M. A. K. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00515-5 · Cited by 329
Methods for Assessing Bone Quality: A Review
Donnelly, E. L. (2010) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-010-1702-0 · Cited by 302
Fracture in human cortical bone: local fracture criteria and toughening mechanisms
Nalla, R. K., Stölken, J. S., Kinney, J. H., & Ritchie, R. O. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.07.010 · Cited by 260
Keyak, J. H., & Rossi, S. A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00152-9 · Cited by 251
Nazarian, A., Stechow, D. V., Zurakowski, D., Müller, R., & Snyder, B. D. (2008) · Calcified Tissue International · doi:10.1007/s00223-008-9174-x · Cited by 251
Trabecular bone microdamage and microstructural stresses under uniaxial compression
Nagaraja, S., Couse, T. L., & Guldberg, R. E. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.013 · Cited by 220
Effect of porosity on the fluid flow characteristics and mechanical properties of tantalum scaffolds
Shimko, D. A., Shimko, V. F., Sander, E. A., Dickson, K. F., & Nauman, E. A. (2005) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30229 · Cited by 216
Maquer, G., Musy, S. N., Wandel, J., Gross, T. J., & Zysset, P. K. (2014) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2437 · Cited by 200
Prediction of fracture location in the proximal femur using finite element models
Keyak, J. H., Rossi, S. A., Jones, K. A., Les, C. M., & Skinner, H. B. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00094-7 · Cited by 200
Increase in bone volume fraction precedes architectural adaptation in growing bone
Tanck, E., Homminga, J. J., van Lenthe, H., & Huiskes, R. (2001) · Bone · doi:10.1016/s8756-3282(01)00464-1 · Cited by 198
Human vertebral body apparent and hard tissue stiffness
Hou, F. J., Lang, S., Hoshaw, S. J., Reimann, D. A., & Fyhrie, D. P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00110-9 · Cited by 196
Nonlinear Finite Element Model Predicts Vertebral Bone Strength and Fracture Site
Imai, K., Ohnishi, I., Bessho, M., & Nakamura, K. (2006) · Spine · doi:10.1097/01.brs.0000225993.57349.df · Cited by 196
Load Sharing Between the Shell and Centrum in the Lumbar Vertebral Body
Silva, M. J., Keaveny, T. M., & Hayes, W. C. (1997) · Spine · doi:10.1097/00007632-199701150-00004 · Cited by 194
Self-citationRelationship Between Primary/Mechanical and Secondary/Biological Implant Stability
Monje, A., Ravidà, A., Wang, H., Helms, J. A., & Brunski, J. (2019) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.19suppl.g1 · Cited by 183
Multi-axial mechanical properties of human trabecular bone
Rincón-Kohli, L., & Zysset, P. K. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-008-0128-z · Cited by 178
Homminga, J. J., McCreadie, B. R., Ciarelli, T. E., Weinans, H., Goldstein, S. A., & Huiskes, R. (2002) · Bone · doi:10.1016/s8756-3282(02)00693-2 · Cited by 177
Gillard, F., Boardman, R., Mavrogordato, M., Hollis, D., Sinclair, I., Pierron, F., & Browne, M. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.09.014 · Cited by 171
Age-dependent Three-dimensional Microcomputed Tomography Analysis of the Human Midpalatal Suture*
Korbmacher, H., Schilling, A. F., Püschel, K., Amling, M., & Kahl‐Nieke, B. (2007) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/s00056-007-0729-7 · Cited by 167
Ford, C. M., & Keaveny, T. M. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00062-0 · Cited by 158
Self-citationThe effect of impact direction on the structural capacity of the proximal femur during falls
Ford, C. M., Keaveny, T. M., & Hayes, W. C. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110311 · Cited by 157
Self-citationMechanical behavior of human trabecular bone after overloading
Keaveny, T. M., Wachtel, E. F., & Kopperdahl, D. L. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170308 · Cited by 155
Self-citationCompression or tension? The stress distribution in the proximal femur
Rudman, K. E., Aspden, R. M., & Meakin, J. R. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-12 · Cited by 155
A fracture mechanics and mechanistic approach to the failure of cortical bone
Ritchie, R. O., Kinney, J. H., Kruzic, J. J., & Nalla, R. K. (2005) · Fatigue & Fracture of Engineering Materials & Structures · doi:10.1111/j.1460-2695.2005.00878.x · Cited by 145
Stauber, M., Rapillard, L., van Lenthe, H., Zysset, P. K., & Müller, R. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060102 · Cited by 145
Roberts, B. C., Perilli, E., & Reynolds, K. J. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.01.001 · Cited by 141
Homminga, J. J., Weinans, H., Gowin, W., Felsenberg, D., & Huiskes, R. (2001) · Spine · doi:10.1097/00007632-200107150-00010 · Cited by 141
Teo, J. C. M., Si-Hoe, K. M., Keh, J. E. L., & Teoh, S. H. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.11.001 · Cited by 138
Mechanical performance of auxetic meta-biomaterials
Kolken, H. M. A., Lietaert, K., van der Sloten, T., Pouran, B., Meynen, A., Loock, G. V., Weinans, H., Scheys, L., & ZADPOOR, A. A. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103658 · Cited by 136
Hellmich, C., Ulm, F., & Dormieux, L. (2004) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-004-0040-0 · Cited by 138
Perilli, E., Baleani, M., Öhman‐Mägi, C., Fognani, R., Baruffaldi, F., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.08.003 · Cited by 137
A micropolar anisotropic constitutive model of cancellous bone from discrete homogenization
Goda, I., Assidi, M., Belouettar, S., & Ganghoffer, J. F. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.07.012 · Cited by 131
Micro-CT finite element model and experimental validation of trabecular bone damage and fracture
Hambli, R. (2013) · Bone · doi:10.1016/j.bone.2013.06.028 · Cited by 129
Bevill, G. R., & Keaveny, T. M. (2008) · Bone · doi:10.1016/j.bone.2008.11.020 · Cited by 129
Self-citationGadeleta, S. J., Boskey, A. L., Paschalis, E. P., Carlson, C. S., Menschik, F., Baldini, T. H., Peterson, M., & Rimnac, C. M. (2000) · Bone · doi:10.1016/s8756-3282(00)00362-8 · Cited by 127
Biomechanical effects of intraspecimen variations in tissue modulus for trabecular bone
Jaasma, M. J., Bayraktar, H. H., Niebur, G. L., & Keaveny, T. M. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00193-2 · Cited by 126
Self-citationNoninvasive Imaging Predicts Failure Load of the Spine with Simulated Osteolytic Defects*†
WHEALAN, K. M., KWAK, S. D., Tedrow, J. R., INOUE, K., & Snyder, B. D. (2000) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200009000-00004 · Cited by 126
Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone
Lee, S. C., Coan, B. S., & Bouxsein, M. (1997) · Bone · doi:10.1016/s8756-3282(97)00076-8 · Cited by 123
MacNeil, J. A., & Boyd, S. K. (2007) · Bone · doi:10.1016/j.bone.2007.02.029 · Cited by 119
A 3D damage model for trabecular bone based on fabric tensors
Zysset, P. K., & Curnier, A. (1996) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)80006-6 · Cited by 117
Fyhrie, D. P., & Vashishth, D. (2000) · Bone · doi:10.1016/s8756-3282(99)00246-x · Cited by 117
Similarity in the fatigue behavior of trabecular bone across site and species
Haddock, S. M., Yeh, O. C., Mummaneni, P. V., Rosenberg, W. S., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00245-8 · Cited by 112
Self-citationAmorphous metals for hard-tissue prosthesis
Demetriou, M. D., Wiest, A., Hofmann, D. C., Johnson, W. L., Han, B., Wolfson, N., Wang, G., & Liaw, P. K. (2010) · JOM · doi:10.1007/s11837-010-0038-2 · Cited by 111
Mechanical behavior of damaged trabecular bone
Keaveny, T. M., Wachtel, E. F., Guo, X.-D. E., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90040-x · Cited by 110
Self-citationChen, B., Li, Y., Xie, D., Yang, X., & Zheng, Z. (2011) · European Spine Journal · doi:10.1007/s00586-011-1744-3 · Cited by 109
Nonlinear Behavior of Trabecular Bone at Small Strains
Morgan, E. F., Yeh, O. C., Chang, W. C. W., & Keaveny, T. M. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1338122 · Cited by 107
Self-citationMechanical properties of vertebrate hard tissues
Currey, J. D. (1998) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/0954411981534178 · Cited by 104
Microdamage Accumulation in Bovine Trabecular Bone in Uniaxial Compression
Moore, T. L. A., & Gibson, L. J. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1428745 · Cited by 103
Homminga, J. J., McCreadie, B. R., Weinans, H., & Huiskes, R. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00125-8 · Cited by 100
The Modified Super-Ellipsoid Yield Criterion for Human Trabecular Bone
Bayraktar, H. H., Gupta, A. K., Kwon, R. Y., Papadopoulos, P., & Keaveny, T. M. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1763177 · Cited by 99
Self-citationRegional variations in microstructural properties of vertebral trabeculae with aging
Gong, H., Zhang, M., Yeung, H. Y., & Qin, L. (2005) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-004-0557-4 · Cited by 97
Dependence of trabecular damage on mechanical strain
Wachtel, E. F., & Keaveny, T. M. (1997) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100150522 · Cited by 95
Self-citationOn the fracture of human dentin: Is it stress‐ or strain‐controlled?
Nalla, R. K., Kinney, J. H., & Ritchie, R. O. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10079 · Cited by 90
Pivonka, P., Buenzli, P. R., Scheiner, S., Hellmich, C., & Dunstan, C. R. (2012) · Engineering Structures · doi:10.1016/j.engstruct.2012.09.006 · Cited by 88
Ultrasonic characterization of human trabecular bone microstructure
Hakulinen, M. A., Day, J. S., Töyräs, J., Weinans, H., & Jurvelin, J. S. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/6/019 · Cited by 87
Zhou, B., Liu, X. S., Wang, J., Lu, X. L., Fields, A. J., & Guo, X. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.11.039 · Cited by 82
Fenech, C. M., & Keaveny, T. M. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798339 · Cited by 81
Self-citationApplication of the Tsai–Wu Quadratic Multiaxial Failure Criterion to Bovine Trabecular Bone
Keaveny, T. M., Wachtel, E. F., Zadesky, S. P., & Arramon, Y. P. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798051 · Cited by 80
Self-citationZhang, X. H., Liu, X. S., Vasilic, B., Wehrli, F. W., Benito, M., Rajapakse, C. S., Snyder, P. J., & Guo, X. E. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080405 · Cited by 79
Finite element prediction of surface strain and fracture strength at the distal radius
Edwards, W. B., & Troy, K. L. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.07.016 · Cited by 79
Teo, J. C. M., Si-Hoe, K. M., Keh, J. E. L., & Teoh, S. H. (2006) · Materials Science and Engineering C · doi:10.1016/j.msec.2006.05.003 · Cited by 79
Varga, P., Pahr, D. H., Baumbach, S. F., & Zysset, P. K. (2010) · Bone · doi:10.1016/j.bone.2010.08.002 · Cited by 78
Uniaxial yield strains for bovine trabecular bone are isotropic and asymmetric
Chang, W. C. W., Christensen, T. M., Pinilla, T. P., & Keaveny, T. M. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170418 · Cited by 77
Self-citationContribution of inter-site variations in architecture to trabecular bone apparent yield strains
Morgan, E. F., Bayraktar, H. H., Yeh, O. C., Majumdar, S., Burghardt, A. J., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.037 · Cited by 77
Self-citationYeni, Y. N., & Fyhrie, D. P. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00155-5 · Cited by 75
Empirical relationships between bone density and ultimate strength: A literature review
Fleps, I., Bahaloo, H., Zysset, P. K., Ferguson, S. J., Pálsson, H., & Helgason, B. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103866 · Cited by 73
Continuous fibre reinforced polymers as connective tissue replacement
Santis, R. D., Sarracino, F., Mollica, F., Netti, P. A., Ambrosio, L., & Nicolais, L. (2003) · Composites Science and Technology · doi:10.1016/j.compscitech.2003.09.008 · Cited by 73
Properties of growing trabecular ovine bone
Nafei, A., Danielsen, C. C., Linde, F., & Hvid, I. (2000) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.82b6.9836 · Cited by 94
Perilli, E., Baleani, M., Öhman‐Mägi, C., Baruffaldi, F., & Viceconti, M. (2007) · Bone · doi:10.1016/j.bone.2007.07.014 · Cited by 71
Compressive properties of trabecular bone in the distal femur
Burgers, T., Mason, J., Niebur, G. L., & Ploeg, H. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.11.018 · Cited by 70
Age-related changes in trabecular bone microdamage initiation
Nagaraja, S., Lin, A., & Guldberg, R. E. (2006) · Bone · doi:10.1016/j.bone.2006.10.028 · Cited by 68
Hellmich, C., & Ulm, F. (2005) · Transport in Porous Media · doi:10.1007/s11242-004-6298-y · Cited by 67
Imai, K., Ohnishi, I., Yamamoto, S., & Nakamura, K. (2008) · Spine · doi:10.1097/brs.0b013e31815e3993 · Cited by 64
Barak, M. M., & Black, M. A. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.12.010 · Cited by 64
Patient‐specific modelling of bone and bone‐implant systems: the challenges
Pankaj, P. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2536 · Cited by 62
Intramedullary femoral nails: one or two lag screws? A preliminary study
Wang, C., Brown, C., Yettram, A. L., & Procter, P. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00081-3 · Cited by 62
Varga, P., Dall’Ara, E., Pahr, D. H., Pretterklieber, M. L., & Zysset, P. K. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0245-3 · Cited by 61
Ho, K., Keyak, J. H., & Powers, C. M. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.010 · Cited by 60
Yeni, Y. N., & Fyhrie, D. P. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00122-2 · Cited by 60
Miura, M., Nakamura, J., Matsuura, Y., Wako, Y., Suzuki, T., Hagiwara, S., Orita, S., Inage, K., Kawarai, Y., Sugano, M., et al. (2017) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-017-1898-1 · Cited by 58
Biaxial Failure Behavior of Bovine Tibial Trabecular Bone
Niebur, G. L., Feldstein, M. J., & Keaveny, T. M. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1517566 · Cited by 57
Self-citationUniaxial strength asymmetry in cellular materials: An analytical model
Ford, C. M., & Gibson, L. J. (1998) · International Journal of Mechanical Sciences · doi:10.1016/s0020-7403(97)00064-7 · Cited by 57
Self-citationFinite Element Prediction of Proximal Femoral Fracture Patterns Under Different Loads
Gómez‐Benito, M. J., García‐Aznar, J. M., & Doblaré, M. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1835347 · Cited by 55
Mixed‐mode failure response of the cement–bone interface
Mann, K. A., Mocarski, R., Damron, L. A., Allen, M. J., & Ayers, D. C. (2001) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(01)00036-5 · Cited by 54
Effect of local density changes on the failure load of the proximal femur
Oden, Z. M., Selvitelli, D. M., & Bouxsein, M. (1999) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100170507 · Cited by 54
Imai, K. (2015) · Aging and Disease · doi:10.14336/ad.2014.0621 · Cited by 52
Metadata
- Authors
- Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C.
- Affiliations
- Beth Israel Deaconess Medical Center (US)
- Harvard University (US)
- Corresponding author
- Keaveny, Tony M.
- ORCID
- Keaveny, Tony M.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1994-09
- Volume
- 27
- Issue
- 9
- Pages
- 1137-1146
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2016308888
- Cited by
- 330
- References
- 36
- Citations by year
- 2026: 8 · 2025: 8 · 2024: 5 · 2023: 7 · 2022: 8 · 2021: 12 · 2020: 17 · 2019: 4 · 2018: 9 · 2017: 18 · 2016: 9 · 2015: 10 · 2014: 15 · 2013: 21 · 2012: 13
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r29ar041481-05)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (R29 AR41481)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Mechanical Engineering › Cellular and Composite Structures
- Keywords
- trabecular bone, tensile strength, compressive strength, yield strength, yield strain, elastic modulus, bone mineral density, bovine tibia, trabecular orientation, bone mechanical properties
- MeSH terms
- Animals, Cattle, Elasticity, Regression Analysis, Stress, Mechanical, Tensile Strength, Tibia, Bone Density, Weight-Bearing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review