The biomechanics of the human patella during passive knee flexion
Open accessThe DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
The fundamental objectives of patello-femoral joint biomechanics include the determination of its kinematics and of its dynamics, as a function of given control parameters like knee flexion or applied muscle forces. On the one hand, patellar tracking provides quantitative information about the joint's stability under given loading conditions, whereas patellar force analyses can typically indicate pathological stress distributions associated for instance with abnormal tracking. The determination of this information becomes especially relevant when facing the problem of evaluating surgical procedures in terms of standard (i.e. non-pathological) knee functionality. Classical examples of such procedures include total knee replacement (TKR) and elevation of the tibial tubercle (Maquet's procedure). Following this perspective, the current study was oriented toward an accurate and reliable determination of the human patella biomechanics during passive knee flexion. To this end, a comprehensive three-dimensional computer model, based on the finite element method, was developed for analyzing articular biomechanics. Unlike previously published studies on patello-femoral biomechanics, this model simultaneously computed the joint's kinematics, associated tendinous and ligamentous forces, articular contact pressures and stresses occurring in the joint during its motion. The components constituting the joint (i.e. bone, cartilage, tendons) were modeled using objective forms of non-linear elastic materials laws. A unilateral contact law allowing for large slip between the patella and the femur was implemented using an augmented Lagrangian formulation. Patellar kinematics computed for two knee specimens were close to equivalent experimental ones (average deviations below 0.5 degrees for the rotations and below 0.5 mm for the translations) and provided validation of the model on a specimen by specimen basis. The ratio between the quadriceps pulling force and the patellar tendon force was less than unity throughout the considered knee flexion range (30-150 degrees), with a minimum near 90 degrees of flexion for both specimens. The contact patterns evolved from the distal part of the retropatellar articular surface to the proximal pole during progressive flexion. The lateral facet bore more pressure than the medial one, with corresponding higher stresses (hydrostatic) in the lateral compartment of the patella. The forces acting on the patella were part of the problem unknowns, thus leading to more realistic loadings for the stress analysis, which was especially important when considering the wide range of variations of the contact pressure acting on the patella during knee flexion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“PFPS can be diagnosed and treated more effectively if normal patellar tracking is known.”
From Patellar Tracking during the Gait Cycle (2011) · cites this paper as [5]
Citations
Cites
Zienkiewicz, O. C. (1989) · Cited by 14,802
An Introduction to Continuum Mechanics
Gurtin, M. E., & Drugan, W. J. (1984) · Journal of Applied Mechanics · doi:10.1115/1.3167763 · Cited by 1,704
An Introduction to Continuum Mechanics
(1981) · Mathematics in Science and Engineering/Mathematics in science and engineering · doi:10.1016/s0076-5392(08)x6102-8 · Cited by 1,508
A first course in rational continuum mechanics
Truesdell, C. A. (1976) · Cited by 1,031
Patellofemoral contact pressures. The influence of q-angle and tendofemoral contact.
Huberti, H. H., & Hayes, W. C. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466050-00010 · Cited by 840
A mixed formulation for frictional contact problems prone to Newton like solution methods
Alart, P., & Curnier, A. (1991) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(91)90022-x · Cited by 758
Self-citationRoentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
Basic orthopaedic biomechanics
Mow, V. C., & Hayes, W. C. (1991) · Medical Entomology and Zoology · Cited by 655
A finite element method for a class of contact-impact problems
Hughes, T. J. R., Taylor, R. L., III, Sackman, J. L., Curnier, A., & Kanok‐Nukulchai, W. (1976) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(76)90018-9 · Cited by 597
Self-citationA survey of finite element analysis in orthopedic biomechanics: The first decade
Huiskes, R., & Chao, E. Y. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90072-6 · Cited by 539 · cited 1×
“A general description of this method, its principles, its possibilities and limitations in orthopedic biomechanics has been published by Huiskes and Chao (1983).”
MethodSelf-citationA planar model of the knee joint to characterize the knee extensor mechanism
Yamaguchi, G. T., & Zajac, F. E. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90179-6 · Cited by 520
Patello-femoral joint mechanics and pathology. 1. Functional anatomy of the patello-femoral joint
Goodfellow, J., Hungerford, D. S., & Zindel, M. (1976) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.58b3.956243 · Cited by 485
Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system
Selvik, G. (1989) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678909154184 · Cited by 478
Reilly, D. T., & Martens, M. (1972) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677208991251 · Cited by 432 · cited 2×
“…spacer and as a lever), have thrown light on increase of the effectiveness of the quadriceps extensor forces (Ellis et al., 1980; Huberti et al., 1984; Reilly and Martens, 1972), and have further invali-dated earlier concepts in which the patello-femoral joint was considered as a pulley mechanism.”
BackgroundMechanical Function of the Patella
Kaufer, H. (1971) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197153080-00007 · Cited by 404
A three-dimensional mathematical model of the knee-joint
Wismans, J., Veldpaus, F., Janssen, J., Huson, A., & Struben, P. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90354-1 · Cited by 351
Disorders of the Patello-femoral Joint
Ficat, R. P., & Hungerford, D. S. (1977) · Cited by 325
A mathematical model of the patellofemoral joint
van Eijden, T. M. G. J., Kouwenhoven, E., Verburg, J., & Weijs, W. A. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90154-5 · Cited by 321 · cited 2×
“…magnitudes were consistent with published experimental results (e.g. Ah-med et al., 1987; Ellis et al., 1980; Huberti et al., 1984) or numerical results (e.g. Hirokawa, 1991; van Eijden et al., 1986; Yamaguchi and Zajac, 1989), all of which found a decreasing ratio up to about 90” of knee flexion.”
BackgroundResultA finite element method for contact problems of solid bodies—Part I. Theory and validation
Chan, S.-K., & Tuba, I. S. (1971) · International Journal of Mechanical Sciences · doi:10.1016/0020-7403(71)90032-4 · Cited by 310
Maquet, P. G. J. (1984) · Springer eBooks · doi:10.1007/978-3-642-61731-7 · Cited by 301
Force ratios in the quadriceps tendon and ligamentum patellae
Huberti, H. H., Hayes, W. C., Stone, J. L., & Shybut, G. T. (1984) · Journal of Orthopaedic Research · doi:10.1002/jor.1100020108 · Cited by 273 · cited 2×
“The predicted patellar tendon force magnitudes were consistent with published experimental results (e.g. Ah-med et al., 1987; Ellis et al., 1980; Huberti et al., 1984) or numerical results (e.g. Hirokawa, 1991; van Eijden et al., 1986; Yamaguchi and Zajac, 1989), all of which found a decreasing…”
BackgroundResultThe Problem of Chondromalacia Patellae
Outerbridge, R. E., & Dunlop, J. A. Y. (1975) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197507000-00024 · Cited by 270 · cited 1×
“Patellar cartilage degeneration has generally been assumed to be directly correlated to some abnormal contact pressure distribution in the patello-femoral joint (Ficat and Hungerford, 1977; Outerbridge and Dunlop, 1975).”
Ligament-Bone Interaction in a Three-Dimensional Model of the Knee
Blankevoort, L., & Huiskes, R. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2894883 · Cited by 267 · cited 1×
“Such models have been widely used for analyzing knee joint kinematics (e.g. Andriacchi et al., 1983; Blankevoort and Huiskes, 1991; Essinger et al., 1989; Wisman et al. 1980), with emphasis brought to the tibio-femoral joint (a comprehensive review can be found in Huiskes, 1992)).”
MethodSelf-citationBrossmann, J., Muhle, C., Schröder, C., Melchert, U. H., Büll, C. C., Spielmann, R. P., & Heller, M. (1993) · Radiology · doi:10.1148/radiology.187.1.8451415 · Cited by 248
The three‐dimensional tracking pattern of the human patella
van Kampen, A., & Huiskes, R. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080309 · Cited by 228 · cited 3×
“…provided quantitative information about the patella motion during knee flexion and about the joint’s stability under given loading conditions (Brossmann et al., 1993; Fujikawa et al., 1983; Heegaard et al., 1994; Reider et al., 1981; Sikorski et al., 1979; van Kampen, 1987; Veress et al., 1979).”
Self-citationAhmed, A. M., Burke, D. L., & Yu, A. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138410 · Cited by 225 · cited 1×
“Accordingly, several studies have reported patel-lo-femoral contact characteristics (Ahmed et al., 1983; Fujikawa et al., 1983; Goodfellow et al., 1976; Goymann and Mueller, 1974; Hille et al., 1985; Huberti and Hayes, 1984; Matthews et al., 1977; Seedhom et al., 1979; Shoji, 1974; Soslowsky et…”
BackgroundLoad Bearing Characteristics of the Patello-Femoral Joint
Matthews, L. S., Sonstegard, D. A., & Henke, J. A. (1977) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677708989740 · Cited by 202 · cited 4×
“Accordingly, several studies have reported patello-femoral contact characteristics (Ahmed et al., 1983; Fujikawa et al., 1983; Goodfellow et al., 1976; Goymann and Mueller, 1974; Hille et al., 1985; Huberti and Hayes, 1984; Matthews et al., 1977; Seedhom et al., 1979; Shoji, 1974; Soslowsky et al., 1990): near extensi…”
BackgroundInfluentialRelief of patellofemoral contact stress by anterior displacement of the tibial tubercle.
Ferguson, A. B., Brown, T. D., Fu, F. H., & Rutkowski, R. (1979) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197961020-00001 · Cited by 198
Force analysis of the patellar mechanism
Ahmed, A. M., Burke, D. L., & Hyder, A. (1987) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100050110 · Cited by 181
Influence of Soft Structures on Patellar Three-Dimensional Tracking
HEEGAARD, J., LEYVRAZ, P.-F., KAMPEN, A. V., RAKOTOMANANA, L., RUBIN, P. J., & BLANKEVOORT, L. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00033 · Cited by 166
Self-citationThree-dimensional mathematical model analysis of the patellofemoral joint
Hirokawa, S. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90331-g · Cited by 160
An augmented Lagrangian method for discrete large‐slip contact problems
Heegaard, J. H., & Curnier, A. (1993) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620360403 · Cited by 152
Self-citationFinite Elements In Biomechanics
Gallagher, R. H., SIMON, B. R., Johnson, P. C., & Gross, J. F. (1982) · Journal of Clinical Engineering · doi:10.1097/00004669-198207000-00019 · Cited by 132
The effect of patellectomy on knee function
Sutton, F., Thompson, C., Lipke, J., & Kettelkamp, D. B. (1976) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197658040-00017 · Cited by 130
Hefzy, M. S., & Grood, E. S. (1988) · Applied Mechanics Reviews · doi:10.1115/1.3151876 · Cited by 126
Mechanical factors and patellofemoral osteoarthrosis.
Seedholm, B. B., Takeda, T., Tsubuku, M., & Wright, V. A. (1979) · Annals of the Rheumatic Diseases · doi:10.1136/ard.38.4.307 · Cited by 122
Model studies of the stiffness characteristics of the human knee joint
Andriacchi, T. P., Mikosz, R. P., Hampton, S. J., & Galante, J. O. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90043-x · Cited by 122 · cited 1×
“Such models have been widely used for analyzing knee joint kinematics (e.g. Andriacchi et al., 1983; Blankevoort and Huiskes, 1991; Essinger et al., 1989; Wisman et al. 1980), with emphasis brought to the tibio-femoral joint (a comprehensive review can be found in Huiskes, 1992)).”
MethodEssinger, J. R., Leyvraz, P., Heegaard, J. H., & Robertson, D. D. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90225-x · Cited by 120
Self-citationSuh, J. ‐., Spilker, R. L., & Holmes, M. H. (1991) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620320704 · Cited by 115
Distribution of subchondral bone density and cartilage thickness in the human patella.
Eckstein, F., Müller‐Gerbl, M., & Putz, R. V. (1992) · PubMed Central · Cited by 112
Rubin, P., Rakotomanana, L. R., Leyvraz, P. F., Zysset, P. K., Curnier, A., & Heegaard, J. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90035-d · Cited by 106 · cited 1×
“The effectiveness of such elements in joint biomechanics was illustrated by, for example, Chan and Rim (1976), Rapperport et al., (1987), Huber-Betzer et al., (1990), Weinans et al., (1990) and Rubin et al., (1993).”
Self-citationBiology and biomechanics of the traumatized synovial joint : the knee as a model
Finerman, G. A. M., Noyes, F. R., & Musculoskeletal (1992) · American Academy of Orthopaedic Surgeons eBooks · Cited by 104
Computational Methods in Solid Mechanics
Curnier, A. (1994) · Solid mechanics and its applications · doi:10.1007/978-94-011-1112-6 · Cited by 100
Self-citationReider, B. J., MARSHALL, J. L., & RING, B. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00025 · Cited by 99
Trends of mechanical consequences and modeling of a fibrous membrane around femoral hip prostheses
Weinans, H., Huiskes, R., & Grootenboer, H. J. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90314-s · Cited by 82
Self-citationFicat, P. (1970) · Cited by 78
Goldstein, S. A., Coale, E. H., Weiss, A. C., Grossnickle, M., Meller, B., & Matthews, L. S. (1986) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100040314 · Cited by 75
Mechanical Factors and the Skeleton: University of Oxford, 31 March – 1 April 1980
Whittle, M. W. (1980) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(80)90154-5 · Cited by 66
Fujikawa, K., Seedhom, B. B., & Wright, V. A. (1983) · Engineering in Medicine · doi:10.1243/emed_jour_1983_012_004_02 · Cited by 66 · cited 2×
“…provided quantitative information about the patella motion during knee flexion and about the joint’s stability under given loading conditions (Brossmann et al., 1993; Fujikawa et al., 1983; Heegaard et al., 1994; Reider et al., 1981; Sikorski et al., 1979; van Kampen, 1987; Veress et al., 1979).”
BackgroundPatellar tracking patterns measurement by analytical X-ray photogrammetry
Veress, S. A., Lippert, F. G., Hou, M. C. Y., & Takamoto, T. (1979) · Journal of Biomechanics · doi:10.1016/0021-9290(79)90014-9 · Cited by 65
Rossikhin, Y. A., & Shitikova, M. V. (1995) · Applied Mechanics Reviews · doi:10.1115/1.3005096 · Cited by 64
Theoretical stress analysis of organ culture osteogenesis
Zenobi‐Wong, M., & Carter, D. R. P. (1990) · Bone · doi:10.1016/8756-3282(90)90060-c · Cited by 63
Huber-Betzer, H., Brown, T. D., & Mattheck, C. G. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90028-2 · Cited by 62
Ellis, M. I., Seedhom, B. B., Wright, V. A., & Dowson, D. (1980) · Engineering in Medicine · doi:10.1243/emed_jour_1980_009_049_02 · Cited by 61 · cited 3×
“The predicted patellar tendon force magnitudes were consistent with published experimental results (e.g. Ah-med et al., 1987; Ellis et al., 1980; Huberti et al., 1984) or numerical results (e.g. Hirokawa, 1991; van Eijden et al., 1986; Yamaguchi and Zajac, 1989), all of which found a decreasing…”
BackgroundResult[Biomechanics of the patello-femoral joint].
Maquet, P. (1978) · PubMed · Cited by 59
Rapperport, D. J., Carter, D. R. P., & Schurman, D. J. (1987) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100050410 · Cited by 53
Hille, E., Schulitz, K.-P., Henrichs, C., & Schneider, T. (1985) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00435942 · Cited by 53
A finite element model for evaluation of tibial prosthesis-bone interface in total knee replacement
Rakotomanana, L. R., Leyvraz, P. F., Curnier, A., Heegaard, J. H., & Rubin, P. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90055-6 · Cited by 52 · cited 1×
“Such features are already available in the present model (Rakotomanana et al., 1992), but were neglected here for simplicity (identification of the associated material constants remains difficult).”
BackgroundSelf-citationEvaluation of the Reliability of Radiological Methods for Registration of Scoliosis
Sevastikoglou, J. A., & Bergquist, E. (1969) · Acta Orthopaedica Scandinavica · doi:10.3109/17453676908989526 · Cited by 50
Stresses in the human knee joint
Chand, R., Haug, E., & Rim, K. (1976) · Journal of Biomechanics · doi:10.1016/0021-9290(76)90120-2 · Cited by 50
The importance of femoral rotation in chondromalacia patellae as shown by serial radiography
Sikorski, J., Peters, J., & Watt, I. (1979) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.61b4.500753 · Cited by 46
A stress analysis of the patella, and how it relates to patellar articular cartilage lesions
Minns, R. J., Birnie, A. J. M., & Abernethy, P. J. (1979) · Journal of Biomechanics · doi:10.1016/0021-9290(79)90019-8 · Cited by 39
Biomechanics of the knee joint: a critical review.
Hirokawa, S. (1993) · PubMed · Cited by 36
A stereophotogrammetric method for measurements of ligament structure
Meijer, R., Huiskes, R., & Kauer, J. M. G. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90042-0 · Cited by 24
Self-citationReithmeier, E., & Plitz, W. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90353-5 · Cited by 22
Structure and function of the human patella: The role of cancellous bone
Townsend, P. R., Miegel, R. E., Rose, R. M., Raux, P., & Radin, E. L. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100417 · Cited by 20
Stereophotogrammetric Determination of Joint Anatomy and Contact Areas
Soslowsky, L. J., Ateshian, G. A., & Mow, V. C. (1990) · Springer eBooks · doi:10.1007/978-1-4612-3450-0_10 · Cited by 18
The three-dimensional tracking pattern of the patella: in vitro analysis
van Kampen, A. (1987) · Radboud Repository (Radboud University) · Cited by 17
Tact: A Contact Analysis Program
Curnier, A. (1987) · Springer eBooks · doi:10.1007/978-3-7091-2967-8_7 · Cited by 17
Self-citationStougård, J. (1970) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677008991982 · Cited by 16
A study of the function of the patella.
FREEHAFER, A. A. (1962) · PubMed · Cited by 12
A scanning electron microscopic study of the degenerative cartilage in patellar chondropathy
Mori, Y., Kubo, M., 宏行, 奥., & Kuroki, Y. (1993) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(05)80419-0 · Cited by 10
LARGE SLIP CONTACT IN BIOMECHANICS : kinematics and stress analysis of the patello-femoral joint
Heegaard, J.-H. (1993) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-1113 · Cited by 7
Self-citationStress Trajectories in the Patella:Study by the Photoelastic Method
da Silva, O., & Bratt, J. F. (1970) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677008991551 · Cited by 4
Mathematical modeling of the knee
Huiskes, R. (1992) · TU/e Research Portal · Cited by 4
Self-citation
Research works printed but not linked: 4
- Bandi, 1970, Chondromallacia Patellae und Femoro-Patellare Arthrose, Helv. Chir. Acta, 11, 1
- Muller, 1980, Etude photoelasticimétrique tridimensionnelle de la patella (rotule). Méthodologie et premiers résultats, Bull. Assoc. Anat., 89
- Shoji, 1974, A study of the patello-femoral contact zones in human knees, J. Jap. orthop. Ass., 48, 85
- Truesdell, 1977, Vol. 1
Cited by
Peña, E., Calvo, B., Martínez, M. A., & Doblaré, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.030 · Cited by 506
Eckstein, F., Cicuttini, F., Raynauld, J.-P., Waterton, J. C., & Peterfy, C. (2006) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2006.02.026 · Cited by 418
Bony and cartilaginous anatomy of the patellofemoral joint
Tecklenburg, K., Dejour, D. H., Hoser, C., & Fink, C. (2005) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-005-0683-0 · Cited by 305
Peña, E., Calvo, B., Martínez, M. A., Palanca, D., & Doblaré, M. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.01.009 · Cited by 285
Gardiner, J. C., & Weiss, J. A. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00113-x · Cited by 238
“The use of computational methods for the study of joint mechanics can elucidate ligament function and yield information that is difficult or impossible to obtain experimentally [2] [3] [9] [16] [17].”
Background
Metadata
- Authors
- Heegaard, J., Leyvraz, P. F., Curnier, A., Rakotomanana, L., & Huiskes, R.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1995-11
- Volume
- 28
- Issue
- 11
- Pages
- 1265-1279
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2166361133
- Cited by
- 180
- References
- 76
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.