The DOI matches its Crossref record.
The spatial resolution capacity of human foveal retina
Open accessAbstract
An image on the retina of a human eye enters the visual system through an array of photoreceptors that sets the boundaries on the spatial detail available for neural representation. In order to investigate the extent to which the input spatial detail is preserved by the human neural system, we compare the anatomical spatial limits as determined by the Nyquist frequency, the highest spatial frequency reconstructable from the cone array, and measures of human acuity, the minimum angle resolvable. We find that the anatomical Nyquist limits determined along the temporal horizontal meridian of a well-studied human retina (Curcio, Sloan, Packer, Hendrickson & Kalina, 1987b) offer a reasonable prediction of human acuity within the retinal region extending from slightly off the exact foveal center to about 2.0 deg of retinal eccentricity. However, we find a narrow peak of anatomical resolution at the foveal center where the acuity appears to be overestimated by cone spacing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 2,790
Self-citationDistribution and morphology of human cone photoreceptors stained with anti‐blue opsin
Curcio, C. A., Allen, K. A., Sloan, K. R., Lerea, C. L., Hurley, J. B., Klock, I. B., & Milam, A. H. (1991) · Journal of Comparative Neurology · doi:10.1002/cne.903120411 · Cited by 629
Self-citationArtificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
In Vivo Imaging of Human Cone Photoreceptor Inner Segments
Scoles, D., Sulai, Y. N., Langlo, C. S., Fishman, G. A., Curcio, C. A., Carroll, J., & Dubra, A. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14542 · Cited by 380
Self-citationOrganization of the human trichromatic cone mosaic
Hofer, H., Carroll, J., Neitz, J., Neitz, M., & Williams, D. R. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2414-05.2005 · Cited by 364
Metadata
- Authors
- Hirsch, J., & Curcio, C. A.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 1989
- Volume
- 29
- Issue
- 9
- Pages
- 1095-1101
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2047482416
- Cited by
- 250
- References
- 0
- FWCI
- 4.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The spatial resolution capacity of human foveal retina. https://app.cochat.ai/papers/10.1016/0042-6989(89)90058-8
- The paper
- Hirsch, J., & Curcio, C. A. (1989). The spatial resolution capacity of human foveal retina. Vision Research. https://doi.org/10.1016/0042-6989(89)90058-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.