[6] Correction for liquid junction potentials in patch clamp experiments
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This chapter describes corrections that have to be applied to measured membrane potentials in patch clamp experiments. Some of them [Eqs. (1)-(3)] are required regardless of the nature of the reference electrode (in the Ringer's solution bath) whenever the pipette-filling solution is different from the bath solution. They represent the liquid junction potentials that are present at the pipette tip before patch formation. In addition, corrections have to be applied when the bath solution is being changed during a measurement (i.e., after seal formation). In that case the following rules apply. (1) The new solution should never get into contact with the bare silver/silver chloride wire of the reference electrode. This requirement is best met by using a salt bridge. (2) The "best" salt bridge is a 3 M KCl bridge with an abrupt KCl-bath fluid boundary at its tip (see above). This bridge does not require any additional potential corrections, but it may lead to KCl poisoning of the bath or become contaminated by solutions used previously. (3) Local solution changes (microperfusion by puffer pipette, U tool or sewer pipe arrangements) as well as recessed KCl bridges require additional corrections, which (together with the simple liquid junction potential correction) are approximately given by Eqs. (6)-(8). It should be stressed that all equations given here represent approximate corrections, since liquid junction potentials are thermodynamically ill-defined. This is particularly relevant for Eqs. (6) and (7) where the sum of two liquid junction potentials appears.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Automated reconstructions were then extensively manually corrected and curated using a range of tools (e.g., virtual finger, polyline) in the Mozak extension (Zoran Popovic, Center for Game Science, University of Washington) of Terafly tools50,53 in Vaa3D.”
From Classification of electrophysiological and morphological neuron types in the mouse visual cortex (2019) · cites this paper as [50]
Citations
Cites
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Self-citationAshcroft, F. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90114-3 · Cited by 982
A patch-clamp study of bovine chromaffin cells and of their sensitivity to acetylcholine
Fenwick, E. M., Marty, A., & Neher, E. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014393 · Cited by 812
Self-citationRates of diffusional exchange between small cells and a measuring patch pipette
Pusch, M., & Neher, E. (1988) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00582316 · Cited by 703
Self-citationLiquid junction potentials and small cell effects in patch-clamp analysis
Barry, P. H., & Lynch, J. W. (1991) · The Journal of Membrane Biology · doi:10.1007/bf01870526 · Cited by 672
Barry, P. H., & Diamond, J. M. (1970) · The Journal of Membrane Biology · doi:10.1007/bf01868010 · Cited by 201
Research works printed but not linked: 2
- P. H. Barry, this series, Vol. 171, p. 678.
- Bockris, 1970, Vol. 1.
Cited by
Items 401–500 of 1,002
Data‐driven integration of hippocampal CA1 synaptic physiology in silico
Ecker, A., Romani, A., Sáray, S., Káli, S., Migliore, M., Falck, J. E., Lange, S., Mercer, A., Thomson, A. M., Muller, E. B., et al. (2020) · Hippocampus · doi:10.1002/hipo.23220 · Cited by 62
“Theoretical LJPs, calculated from the reported pipette and bath solutions were obtained from Moradi and Ascoli (2020).”
MethodInfluentialHyperthermia Modulates Respiratory Pacemaker Bursting Properties
Tryba, A. K., & Ramirez, J. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00752.2003 · Cited by 55
“The Vm values were corrected for liquid junction potentials as described by Neher (1992).”
MethodAnion Permeation in Human ClC-4 Channels
Hebeisen, S., Heidtmann, H., Cosmelli, D. J., Gonzalez, C. L., Poser, B., Latorre, R., Alvarez, O. A., & Fahlke, C. M. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75036-x · Cited by 59
“Barry, University of South Wales, Sydney, Australia; see also Barry, 1994) or directly measured (Neher, 1992) were used to correct results.”
MethodSuh, S., Moran, N., & Lee, Y. (2000) · Plant Physiology · doi:10.1104/pp.123.3.833 · Cited by 57
“The liquid-junction potential of 214 mV was calculated based on the differences between the pipette and the bath solutions (Neher, 1992) and added, at the onset of the analysis, to all values of the command (pipette) potential.”
MethodMechanism of Irregular Firing of Suprachiasmatic Nucleus Neurons in Rat Hypothalamic Slices
Kononenko, N. I., & Dudek, F. E. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00314.2003 · Cited by 55
“Bicuculline (10–30 M) suppressed IPSPs and converted an irregular pattern to a more regular firing.”
BackgroundZhang, J., Shen, W., & Slaughter, M. M. (1997) · The Journal of General Physiology · doi:10.1085/jgp.110.1.45 · Cited by 55
“The tip potential was measured for each pipette solution (Neher, 1992), and the correction factor is mentioned in results , particularly where reversal potential measurements are presented.”
BackgroundRectification of the Channelrhodopsin Early Conductance
Gradmann, D., Berndt, A., Schneider, F., & Hegemann, P. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.07.040 · Cited by 61
Meis, S., Munsch, T., Sosulina, L., & Pape, H. (2007) · Molecular and Cellular Neuroscience · doi:10.1016/j.mcn.2007.03.012 · Cited by 56
Chabbert, C., Méchaly, I., Sieso, V., Giraud, P., Brugeaud, A., Lehouelleur, J., Couraud, F., Valmier, J., & Sans, A. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2003.043034 · Cited by 60
“Voltages were corrected off-line for liquid junction potentials measured according to Neher (1992): _2 mV between internal and external control solutions, _5 mV between the internal caesium solution and the external TEA solution, and _10 mV measured between the internal potassium gluconate solution…”
MethodDevelopment of Inward Rectification and Control of Membrane Excitability in Mesencephalic V Neurons
Tanaka, S., Wu, N., Hsaio, C.-F., Turman, J. E., & Chandler, S. H. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00850.2002 · Cited by 60
“Liquid junctional potential (Х Ϫ5 mV), resulting from the K-gluconate containing electrode, was measured and corrected off-line (Neher 1992).”
Agonist-specific voltage-dependent gating of lysosomal two-pore Na+ channels
Zhang, X., Chen, W., Li, P., Calvo, R., Southall, N. T., Hu, X., Bryant‐Genevier, M., Feng, X., Geng, Q., Gao, C., et al. (2019) · eLife · doi:10.7554/elife.51423 · Cited by 53
“The liquid junction potentials were measured and corrected as described (Neher, 1992).”
MethodDirect Demonstration of Exocytosis and Endocytosis in Single Mouse Juxtaglomerular Cells
Friis, U. G., Jensen, B. L., Aas, J. K., & Skøtt, O. (1999) · Circulation Research · doi:10.1161/01.res.84.8.929 · Cited by 53
Chen, Q. X., Perkins, K. L., Choi, D. W., & Wong, R. K. S. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-11-04032.1997 · Cited by 53
“Liquid junction potentials (Vlj) were measured using the procedure of Neher (1992).”
MethodCation sensitivity and kinetics of guard-cell potassium channels differ among species
Dietrich, P., Drèyer, I., Wiesner, P., & Hedrich, R. (1998) · Planta · doi:10.1007/s004250050322 · Cited by 53
Bertrand, S. S., Nouel, D., Morin, F., Nagy, F., & Lacaille, J. (2003) · Synapse · doi:10.1002/syn.10247 · Cited by 55
Activation of TREK Currents by the Neuroprotective Agent Riluzole in Mouse Sympathetic Neurons
Cadaveira-Mosquera, A., Ribeiro, S. J., Reboreda, A., Pérez, M., & Lamas, J. A. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.2791-10.2011 · Cited by 55
“Junction potentials 5 mV were not corrected (Neher, 1992).”
BackgroundKang, J., Kang, N., Yu, Y., Zhang, J., Petersen, N., Tian, G. F., & Nedergaard, M. (2010) · Neuroscience · doi:10.1016/j.neuroscience.2010.06.020 · Cited by 50
“1 mV in our experimental conditions according to the methods reported previously (Neher, 1992).”
InfluentialC-Terminus-Mediated Voltage Gating of Arabidopsis Guard Cell Anion Channel QUAC1
Mumm, P., Imes, D., Martinoia, E., Al‐Rasheid, K. A. S., Geiger, D., Marten, I., & Hedrich, R. (2013) · Molecular Plant · doi:10.1093/mp/sst008 · Cited by 52
Romero, M., Reboreda, A., Sánchez, E., & Lamas, J. A. (2004) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2004.03363.x · Cited by 55
Lo, F.-S., Guido, W., & Erzurumlu, R. S. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.5.2765 · Cited by 49
“After " break-in, " the serial resistance was compensated with bridge balance, and junction potential (Neher 1992) filled the patch electrodes with 1% biocytin dissolved in potassiumbased solution.”
Murakami, M., Yamamura, H., Suzuki, T., Kang, M., Ohya, S., Murakami, A. M., Miyoshi, I., Sasano, H., Muraki, K., Hano, T., et al. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m211380200 · Cited by 52
High Intracellular Cl−Concentrations Depress G-Protein-Modulated Ionic Conductances
Lenz, R. A., Pitler, T. A., & Alger, B. E. (1997) · Journal of Neuroscience · doi:10.1523/jneurosci.17-16-06133.1997 · Cited by 55
“Liquid junction potentials between the three intracellular solutions and the extracellular solution were measured according to the method of Neher (1992).”
MethodKüppers-Munther, B., Letzkus, J. J., Lüer, K., Technau, G. M., Schmidt, H., & Prokop, A. (2004) · Developmental Biology · doi:10.1016/j.ydbio.2004.01.038 · Cited by 56
“The liquid junction potential of 10 mV generated in these solutions was corrected online (Neher, 1992).”
BackgroundAMPA and NMDA receptor-mediated currents in developing dentate gyrus granule cells
Ye, G.-L., Yi, S., Gamkrelidze, G. N., Pasternak, J. F., & Trommer, B. L. (2005) · Developmental Brain Research · doi:10.1016/j.devbrainres.2004.12.002 · Cited by 55
Retinal Bipolar Cell Input Mechanisms in Giant Danio. II. Patch-Clamp Analysis of on Bipolar Cells
Wong, K. Y., Cohen, E. D., & Dowling, J. E. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00270.2004 · Cited by 51
“The liquid junction potentials were measured in the manner described in Neher (1992), and they were 9.033 0.076 mV (n 6) and 13.43 0.28 mV (n 6) for cesium- and potassium-based internal solutions (see J Neurophysiol • VOL 93 • JANUARY 2005 • www.jn.org Chemicals and solutions), respectively.”
InfluentialControl of descending vasa recta pericyte membrane potential by angiotensin II
Pallone, T. L., & Huang, J. (2002) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00306.2001 · Cited by 51
“Our measurement of this offset, obtained using a flowing 3 M KCl bridge as the bath electrode as described by Neher (26), was 9.7 0.3 mV (n 4).”
MethodInfluentialContribution of NR2B Subunits to Synaptic Transmission in Amygdaloid Interneurons
Szinyei, C., Stork, O., & Pape, H.-C. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-07-02549.2003 · Cited by 49
“Liquid junction potentials in all voltage-clamp experiments were corrected (Neher, 1992).”
MethodSchrader, L. A., & Tasker, J. G. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.6.3428 · Cited by 51
“Liquid junction potentials (11 Slice preparation mV) were corrected according to Neher (1992).”
MethodPutative pore‐loops of TMEM16/anoctamin channels affect channel density in cell membranes
Adomaviciene, A., Smith, K. J., Garnett, H., & Tammaro, P. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2013.251660 · Cited by 50
“Liquid junction potentials were calculated (Barry & Lynch, 1991; Neher, 1992) and corrected off-line.”
MethodVecchia, D., Tottene, A., van den Maagdenberg, A. M. J. M., & Pietrobon, D. (2015) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2015.00008 · Cited by 50
“A liquid junction potential (LJP) of −8 mV should be added to all voltages to obtain the correct membrane potentials (Neher, 1992).”
BackgroundOptimizing the Electrical Stimulation of Retinal Ganglion Cells
Hadjinicolaou, A. E., Savage, C. O., Apollo, N. V., Garrett, D. J., Cloherty, S. L., Ibbotson, M. R., & O'Brien, B. J. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2361900 · Cited by 47
Voltage-clamp recordings of light responses from wild-type and mutant mouse cone photoreceptors
Ingram, N. T., Sampath, A. P., & Fain, G. (2019) · The Journal of General Physiology · doi:10.1085/jgp.201912419 · Cited by 56
“All values of cone membrane potential Vm have been corrected for the liquid junction potential (Neher, 1992), which was measured to be approximately 10 mV for this internal solution.”
BackgroundChambard, J., Chabbert, C., Sans, A., & Desmadryl, G. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0141r.x · Cited by 50
“Furthermore, between E15 and birth there is a substantial development of synaptic contacts between primary vestibular afferents and sensory hair cells (Nordemar, 1983; Mbiene et al. 1988).”
BackgroundInfluentialGambale, F., Bregante, M., Stragapede, F., & Cantù, A. M. (1996) · The Journal of Membrane Biology · doi:10.1007/s002329900133 · Cited by 50
Anions permeate and gate GCAC1, a voltage‐dependent guard cell anion channel
Dietrich, P., & Hedrich, R. (1998) · The Plant Journal · doi:10.1046/j.1365-313x.1998.00225.x · Cited by 60
Voltage Offsets in Patch-Clamp Experiments
Neher, E. (1995) · Springer eBooks · doi:10.1007/978-1-4419-1229-9_6 · Cited by 50
Self-citationA Subtype of Olfactory Bulb Interneurons Is Required for Odor Detection and Discrimination Behaviors
Takahashi, H., Ogawa, Y., Yoshihara, S.-I., Asahina, R., Kinoshita, M., Kitano, T., Kitsuki, M., Tatsumi, K., Okuda, M., Tatsumi, K., et al. (2016) · Journal of Neuroscience · doi:10.1523/jneurosci.2783-15.2016 · Cited by 44
George, A. A., Vieira, J. M., Xavier-Jackson, C., Gee, M. T., Cirrito, J. R., Bimonte-Nelson, H. A., Picciotto, M. R., Lukas, R. J., & Whiteaker, P. (2021) · The Journal of Neuroscience · doi:10.1523/jneurosci.0876-20.2020 · Cited by 46
Carter, B. C., & Bean, B. P. (2011) · Journal of Neurophysiology · doi:10.1152/jn.01056.2010 · Cited by 48
“Reported membrane potentials are corrected for a liquid junction potential of Ϫ8 mV between the internal solution and the Tyrode's solution in which current was zeroed before sealing onto the cell, measured using a flowing 3 M KCl reference electrode as described by Neher (1992).”
MethodStumpff, F., Strauß, O., Boxberger, M., & Wiederholt, M. (1997) · PubMed · doi:10.17169/refubium-21370 · Cited by 49
A Cationic Channel in the Guard Cell Tonoplast of Allium cepa
Amodeo, G., Escobar, A. L., & Zeiger, E. (1994) · PLANT PHYSIOLOGY · doi:10.1104/pp.105.3.999 · Cited by 53
Broicher, T., Kanyshkova, T. G., Landgraf, P., Rankovic, V., Meuth, P., Meuth, S. G., Pape, H., & Budde, T. (2007) · Molecular and Cellular Neuroscience · doi:10.1016/j.mcn.2007.05.013 · Cited by 52
“Data were not corrected for the liquid junction potential (Neher, 1992).”
BackgroundKarlsson, U., Sjödin, J., Möller, K. Ä., Johansson, S., Wikström, L., & Näsström, J. (2002) · Neuroscience · doi:10.1016/s0306-4522(02)00140-9 · Cited by 53
Presence of a calcium-activated chloride current in mouse ventricular myocytes
Xu, Y., Dong, P. H., Zhang, Z., Ahmmed, G. U., & Chiamvimonvat, N. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00044.2002 · Cited by 48
“Liquid-junction potentials were measured as previously described (37) and all data were corrected for the liquid-junction potentials.”
MethodReboreda, A., Sanchez, E., Romero, M., & Lamas, J. A. (2003) · The Journal of Physiology · doi:10.1111/j.1469-7793.2003.00191.x · Cited by 48
“Liquid junction potentials measured using a 3 M KCl reference electrode ranged from 4 to 6 mV and traces were corrected accordingly (Neher, 1992).”
MethodCONNAUGHTON, V. P., & Maguire, G. (1998) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.1998.00152.x · Cited by 48
“The liquid junction potential, recorded using a 3 M KCl reference electrode separated from the bath solution by a salt bridge (Neher, 1992), was – 6 mV; values presented in the text are uncorrected.”
MethodCharacterization of Chloride Currents and Their Noradrenergic Modulation in Rat Taste Receptor Cells
Herness, M. S., & Sun, X. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.1.260 · Cited by 48
“2 and 7) because these measurements were largely qualitative and agar bridge are, at best, imperfect solutions (Neher 1992).”
BackgroundPetrucci, C., Resta, V., Fieni, F., Bigiani, A., & Bagnoli, P. (2001) · Naunyn-Schmiedeberg s Archives of Pharmacology · doi:10.1007/s002100100422 · Cited by 48
Reevaluation of Ca2+ channel types and their modulation in bullfrog sympathetic neurons
Elmslie, K. S., Kammermeier, P. J., & Jones, S. W. (1994) · Neuron · doi:10.1016/0896-6273(94)90471-5 · Cited by 48
Biased modulators of NMDA receptors control channel opening and ion selectivity
Perszyk, R. E., Swanger, S. A., Shelley, C., Khatri, A., Fernández‐Cuervo, G., Epplin, M. P., Zhang, J., Le, P., Bülow, P., Garnier‐Amblard, E. C., et al. (2020) · Nature Chemical Biology · doi:10.1038/s41589-019-0449-5 · Cited by 53
Recruitment of plasma membrane voltage‐dependent calcium‐permeable channels in carrot cells.
Thuleau, P., Moreau, M., Schroeder, J. I., & Ranjeva, R. (1994) · The EMBO Journal · doi:10.1002/j.1460-2075.1994.tb06928.x · Cited by 47
Cell Type-Specific Regulation of Ion Channels Within the Maize Stomatal Complex
Mumm, P., Wolf, T., Fromm, J., Roelfsema, M. R. G., & Marten, I. (2011) · Plant and Cell Physiology · doi:10.1093/pcp/pcr082 · Cited by 46
“The clamped voltages were corrected offline for the liquid junction potential (Neher 1992).”
BackgroundFunctional characterization of dI6 interneurons in the neonatal mouse spinal cord
Dyck, J., Lanuza, G. M., & Gosgnach, S. (2012) · Journal of Neurophysiology · doi:10.1152/jn.01132.2011 · Cited by 42
Ion channels and calcium signaling in motile cilia
Doerner, J. F., Delling, M., & Clapham, D. E. (2015) · eLife · doi:10.7554/elife.11066 · Cited by 50
“Liquid junction potentials were measured using a salt bridge filled with 3 M KCl solution, as described by Neher (Neher, 1992).”
MethodEhrengruber, M. U., Renggli, M., Raineteau, O., Hennou, S., Vähä-Koskela, M. J. V., Hinkkanen, A., & Lundstrom, K. H. (2003) · Journal of NeuroVirology · doi:10.1080/13550280390173346 · Cited by 47
“1 mV measured as described (Neher, 1992) was taken into account for all data.”
InfluentialMechanisms of Na+-K+pump regulation in cardiac myocytes during hyposmolar swelling
Bewick, N. L., Fernandes, C., Pitt, A. D., Rasmussen, H., & Whalley, D. W. (1999) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1999.276.5.c1091 · Cited by 46
Novel charged sodium and calcium channel inhibitor active against neurogenic inflammation
Lee, S., Jo, S., Talbot, S., Zhang, H.-X. B., Kotoda, M., Andrews, N. A., Puopolo, M., Liu, P. W., Jacquemont, T., Pascal, M., et al. (2019) · eLife · doi:10.7554/elife.48118 · Cited by 48
“Reported membrane potentials are corrected for a liquid junction potential of 10 mV between the internal solution and the Tyrode’s solution in which current was zeroed before sealing onto the cell, measured using a flowing 3 M KCl reference electrode as described by Neher (1992).”
MethodA-type K+ Current of Dopamine and GABA Neurons in the Ventral Tegmental Area
Koyama, S., & Appel, S. B. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01318.2005 · Cited by 44
Effects of Sodium Pump Activity on Spontaneous Firing in Neurons of the Rat Suprachiasmatic Nucleus
Wang, Y.-C., & Huang, R.-C. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01369.2005 · Cited by 45
“The measured liquid junction potential was 13 mV (Neher 1992) and was not corrected for in measurements of voltages.”
BackgroundTumour development in Arabidopsis thaliana involves the Shaker‐like K+ channels AKT1 and AKT2/3
Deeken, R., Ivashikina, N., Czirjak, T., Philippar, K., Becker, D., Ache, P., & Hedrich, R. (2003) · The Plant Journal · doi:10.1046/j.1365-313x.2003.01766.x · Cited by 50
Ilan, N., Schwartz, A., & Moran, N. (1996) · The Journal of Membrane Biology · doi:10.1007/s002329900142 · Cited by 45
“The measured membrane potential was corrected for liquid-junction potential determined separately using the experimental solutions and 3 M KCl-filled agar bridges (−17 mV; Neher, 1992).”
MethodLi, Y., & Halm, D. R. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00065.2001 · Cited by 46
“Junction potentials at pipette tip and bath reference bridge were calculated to correct holding voltages (1, 38).”
MethodCohen, E. D. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.80.6.2975 · Cited by 46
Craven, M., Sergeant, G. P., Hollywood, M. A., McHale, N. G., & Thornbury, K. D. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.058628 · Cited by 46
“Where stated, reversal potential data were corrected for junction potentials of –3 mV in PSS and +2 mV in low-chloride solution according to the method described by Neher (1992). Voltage-clamp commands were delivered with an Axopatch 1D patch-clamp amplifier (Axon Instruments) and currents were recorded by means of a…”
MethodFunctional expression and characterization of a plant K+ channel gene in a plant cell model
Bei, Q., & Luan, S. (1998) · The Plant Journal · doi:10.1046/j.1365-313x.1998.00084.x · Cited by 45
Tsubokawa, H., Oguro, K., Robinson, H. P., Masuzawa, T., & Kawai, N. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021750 · Cited by 45
Properties of a protein kinase C-activated chloride current in guinea pig ventricular myocytes.
Walsh, K. B., & Long, K. J. (1994) · Circulation Research · doi:10.1161/01.res.74.1.121 · Cited by 45
Mapping the function of neuronal ion channels in model and experiment
Podlaski, W. F., Seeholzer, A., Groschner, L. N., Miesenböck, G., Ranjan, R., & Vogels, T. P. (2017) · eLife · doi:10.7554/elife.22152 · Cited by 55
Zhai, Y., Wen, Z., Han, Y., Zhuo, W., Wang, F., Xi, C., Liu, J., Gao, P., Zhao, H., Wang, Y., et al. (2020) · Cell Calcium · doi:10.1016/j.ceca.2020.102261 · Cited by 44
Chabbert, C., Chambard, J., Sans, A., & Desmadryl, G. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.3.1017 · Cited by 46
“The liquid junction potential between the internal and the extracellular solution, measured according to Neher (1992), was26.”
BackgroundTartas (2010) · Frontiers in Neural Circuits · doi:10.3389/neuro.04.004.2010 · Cited by 44
“A liquid junction potential of +15 mV was experimentally determined (Neher, 1992) and records were corrected for this potential.”
Du, J., & Yang, X. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.2.666 · Cited by 45
“The liquid junction potential of the recording electrode was measured (Neher 1992) and routinely corrected.”
MethodLuther, J. A., Halmos, K. C., & Tasker, J. G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.4.1814 · Cited by 42
Amiloride-sensitive Na+ current in the granular duct cells of mouse mandibular glands
Dinudom, A., Young, J., & Cook, D. I. (1993) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00374977 · Cited by 44
KDC1, a Novel Carrot Root Hair K+Channel
Downey, P. M., Szabó, I., Ivashikina, N., Negro, A., Guzzo, F., Ache, P., Hedrich, R., Terzi, M., & Schiavo, F. L. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m002962200 · Cited by 46
Identification of a Probable Pore-Forming Domain in the Multimeric Vacuolar Anion Channel AtALMT9
Zhang, J., Baetz, U., Krügel, U., Martinoia, E., & Angeli, A. D. (2013) · PLANT PHYSIOLOGY · doi:10.1104/pp.113.219832 · Cited by 49
“Liquid junction potentials were measured and corrected when higher than 62 mV (Neher, 1992).”
BackgroundGeis, H.-R. A. P., & Borst, J. G. G. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90966.2008 · Cited by 43
“Membrane potentials were corrected for an estimated 11-mV junction potential (Neher 1992).”
MethodWang, X., Takeya, K., Aaronson, P. I., Loutzenhiser, K., & Loutzenhiser, R. (2008) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00200.2007 · Cited by 43
“Measurements of the junction potential as described (29) indicated that it was 8 mV (bath pipette potential).”
BackgroundMaguire, E. P., Mitchell, E. A., Greig, S. J., Corteen, N. L., Balfour, D. J. K., Swinny, J. D., Lambert, J. J., & Belelli, D. (2013) · Neuropsychopharmacology · doi:10.1038/npp.2013.326 · Cited by 44
“The liquid junction potential was corrected (Neher, 1992).”
Rienmüller, F., Drèyer, I., Schönknecht, G., Schulz, A., Schumacher, K., Nagy, R., Martinoia, E., Marten, I., & Hedrich, R. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.310367 · Cited by 43
Effect of Ciguatoxin 3C on Voltage-Gated Na+ and K+ Currents in Mouse Taste Cells
Ghiaroni, V., Fuwa, H., Inoue, M., Sasaki, M., Miyazaki, K., Hirama, M., Yasumoto, T., Rossini, G. P., Scalera, G., & Bigiani, A. (2006) · Chemical Senses · doi:10.1093/chemse/bjl008 · Cited by 43
“gluconate pipette solution) measured between pipette solution and Tyrode (bath) solution (Neher, 1992).”
MethodNägerl, U. V., & Módy, I. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.039bo.x · Cited by 43
“The liquid junction potential was fairly small ( 3 mV) (Neher, 1992) and was not compensated for.”
BackgroundAdenosine stimulates Cl−channels of nonpigmented ciliary epithelial cells
Carré, D. A., Mitchell, C. H., Peterson-Yantorno, K., Coca‐Prados, M., & Civan, M. M. (1997) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1997.273.4.c1354 · Cited by 44
Connexin-Based Channels in Astrocytes: How to Study Their Properties
Giaume, C., Orellana, J. A., Abudara, V., & Sáez, J. C. (2011) · Methods in molecular biology · doi:10.1007/978-1-61779-452-0_19 · Cited by 45
Zhang, N., Lu, X., Wu, S., Li, X., Duan, J., Chen, C., Wang, W., Song, H., Tong, J., Li, S., et al. (2018) · Cytotherapy · doi:10.1016/j.jcyt.2018.02.371 · Cited by 53
Cholinergic Modulation of Neuronal Excitability in the Rat Suprachiasmatic Nucleus
Yang, J.-J., Wang, Y., Cheng, P.-C., Kuo, Y.-J., & Huang, R. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00877.2009 · Cited by 46
Deleuze, C., Alonso, G., Lefevre, I. A., Duvoid, A., & Hussy, N. (2005) · Neuroscience · doi:10.1016/j.neuroscience.2005.01.060 · Cited by 51
Differential expression of three T-type calcium channels in retinal bipolar cells in rats
HU, C., Bi, A., & Pan, Z. (2009) · Visual Neuroscience · doi:10.1017/s0952523809090026 · Cited by 42
“Liquid junction potentials were corrected according to the procedure described by Neher (1992).”
MethodNonspecific Cation Current Associated with Native Polycystin-2 in HEK-293 Cells
Pelucchi, B., Aguiari, G., Pignatelli, A., Manzati, E., Witzgall, R., SENNO, L. D., & Belluzzi, O. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2004121146 · Cited by 42
Cell membrane stretch in osteoclasts triggers a self-reinforcing Ca2+ entry pathway
Wiltink, A., Nijweide, P. J., Scheenen, W. J. J. M., Ypey, D. L., & van Duijn, B. (1995) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00373987 · Cited by 42
“The reversal potential, Erev was corrected for the bimodally distributed Em [28] and for liquid junction potentials [25].”
BackgroundBrüggemann, L., Dietrich, P., Drèyer, I., & Hedrich, R. (1999) · Planta · doi:10.1007/s004250050494 · Cited by 42
Ketzschmar, H. A., Giese, A., Brown, D. R., Herms, J. W., Keller, B. U., Schmidt, B., & Groschup, M. H. (1997) · Journal of neural transmission. Supplementum · doi:10.1007/978-3-7091-6842-4_19 · Cited by 50
Elicitor-induced chloride efflux and anion channels in tobacco cell suspensions
Zimmermann, S., Frachisse, J., Thomine, S., Barbier‐Brygoo, H., & Guern, J. (1998) · Plant Physiology and Biochemistry · doi:10.1016/s0981-9428(98)80015-6 · Cited by 42
Foll, F. L., Louiset, E., Castel, H., Vaudry, H., & Cazin, L. (1997) · European Journal of Pharmacology · doi:10.1016/s0014-2999(97)01042-x · Cited by 42
Imaging neuronal calcium fluorescence at high spatio-temporal resolution
Canepari, M., & Mammano, F. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00127-7 · Cited by 42
“(E) Space-time 3D plot: receding axis is distance along the cell profile, from ROI 1 to 10, abscissa is time, surface height gives local fluorescence change (also encoded as surface color).”
BackgroundMethodRodríguez‐Contreras, A., Nonner, W., & Yamoah, E. N. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.013312 · Cited by 41
Stegen, M., Young, C. C., Haas, C. A., Zentner, J., & Wolfart, J. (2009) · Epilepsia · doi:10.1111/j.1528-1167.2009.02025.x · Cited by 44
“(Neher, 1992) and voltages were appropriately corrected offline.”
Partition of Transient and Sustained Inhibitory Glycinergic Input to Retinal Ganglion Cells
Han, Y., Zhang, J., & Slaughter, M. M. (1997) · Journal of Neuroscience · doi:10.1523/jneurosci.17-10-03392.1997 · Cited by 41
“Pipette resistances were 4 –7 MV. Access resistance was not compensated, but tip potentials were measured and corrected (Neher, 1992).”
BackgroundRohrbough, J. C., & Spitzer, N. C. (1999) · Journal of Neuroscience · doi:10.1523/jneurosci.19-19-08528.1999 · Cited by 44
“Liquid junction potentials were measured (Neher, 1992) between the pipette and bath solutions for each combination of solutions used in reversal potential experiments and varied between 25 and 29 mV.”
MethodBoehme, R., Uebele, V. N., Renger, J. J., & Pedroarena, C. M. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00612.2011 · Cited by 40
Metadata
- Authors
- Neher, E.
- Affiliations
- Max Planck Society (DE)
- Corresponding author
- Neher, Erwin
- ORCID
- Neher, Erwin
- Venue
- Methods in Enzymology
- Publisher
- Elsevier
- Published
- 1992
- Volume
- 207
- Pages
- 123-131
- ISSN
- 0076-6879 (ISSN-L)
- OpenAlex
- W1561818412
- Cited by
- 1,132
- References
- 6
- Citations by year
- 2026: 14 · 2025: 17 · 2024: 11 · 2023: 13 · 2022: 19 · 2021: 19 · 2020: 35 · 2019: 26 · 2018: 25 · 2017: 21 · 2016: 24 · 2015: 29 · 2014: 25 · 2013: 31 · 2012: 28
- FWCI
- 27.85
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- Methods in enzymology on CD-ROM/Methods in enzymology (publishedVersion)
- PubMed (publishedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- liquid junction potential, patch clamp, reference electrode, Ag/AgCl electrodes, salt bridges, microperfusion
- MeSH terms
- Amplifiers, Electronic, Electrophysiology, Membrane Potentials, Microelectrodes, Potentiometry, Solutions, Artifacts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.