[6] Correction for liquid junction potentials in patch clamp experiments
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This chapter describes corrections that have to be applied to measured membrane potentials in patch clamp experiments. Some of them [Eqs. (1)-(3)] are required regardless of the nature of the reference electrode (in the Ringer's solution bath) whenever the pipette-filling solution is different from the bath solution. They represent the liquid junction potentials that are present at the pipette tip before patch formation. In addition, corrections have to be applied when the bath solution is being changed during a measurement (i.e., after seal formation). In that case the following rules apply. (1) The new solution should never get into contact with the bare silver/silver chloride wire of the reference electrode. This requirement is best met by using a salt bridge. (2) The "best" salt bridge is a 3 M KCl bridge with an abrupt KCl-bath fluid boundary at its tip (see above). This bridge does not require any additional potential corrections, but it may lead to KCl poisoning of the bath or become contaminated by solutions used previously. (3) Local solution changes (microperfusion by puffer pipette, U tool or sewer pipe arrangements) as well as recessed KCl bridges require additional corrections, which (together with the simple liquid junction potential correction) are approximately given by Eqs. (6)-(8). It should be stressed that all equations given here represent approximate corrections, since liquid junction potentials are thermodynamically ill-defined. This is particularly relevant for Eqs. (6) and (7) where the sum of two liquid junction potentials appears.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Automated reconstructions were then extensively manually corrected and curated using a range of tools (e.g., virtual finger, polyline) in the Mozak extension (Zoran Popovic, Center for Game Science, University of Washington) of Terafly tools50,53 in Vaa3D.”
From Classification of electrophysiological and morphological neuron types in the mouse visual cortex (2019) · cites this paper as [50]
Citations
Cites
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Self-citationAshcroft, F. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90114-3 · Cited by 982
A patch-clamp study of bovine chromaffin cells and of their sensitivity to acetylcholine
Fenwick, E. M., Marty, A., & Neher, E. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014393 · Cited by 812
Self-citationRates of diffusional exchange between small cells and a measuring patch pipette
Pusch, M., & Neher, E. (1988) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00582316 · Cited by 703
Self-citationLiquid junction potentials and small cell effects in patch-clamp analysis
Barry, P. H., & Lynch, J. W. (1991) · The Journal of Membrane Biology · doi:10.1007/bf01870526 · Cited by 672
Barry, P. H., & Diamond, J. M. (1970) · The Journal of Membrane Biology · doi:10.1007/bf01868010 · Cited by 201
Research works printed but not linked: 2
- P. H. Barry, this series, Vol. 171, p. 678.
- Bockris, 1970, Vol. 1.
Cited by
Items 101–200 of 1,002
Signal Propagation in Drosophila Central Neurons
Gouwens, N. W., & Wilson, R. I. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.0764-09.2009 · Cited by 156
“All traces are corrected for the liquid junction potential (Neher, 1992).”
BackgroundSynaptic Currents Generating the Inhibitory Surround of Ganglion Cells in the Mammalian Retina
Flores-Herr, N., Protti, D. A., & Wässle, H. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-13-04852.2001 · Cited by 167
“Voltages are given after correction for liquids junction potentials (approximately 215 mV) (Neher, 1992).”
BackgroundBimodal Control of a Ca2+-Activated Cl− Channel by Different Ca2+ Signals
Kuruma, A., & Hartzell, H. C. (2000) · The Journal of General Physiology · doi:10.1085/jgp.115.1.59 · Cited by 170
Tottene, A., Volsen, S., & Pietrobon, D. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-01-00171.2000 · Cited by 170
“Liquid junction potential at the pipette tip was 28 mV (pipette negative), and that between the Tyrode’s solution in the experimental chamber and the external recording solution (flowing from the capillary tube) was 24 mV; these two junction potentials should be added to all voltages to obtain the correct values of me…”
Meuth, S. G., Budde, T., Kanyshkova, T., Broicher, T., Munsch, T., & Pape, H.-C. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-16-06460.2003 · Cited by 170
“A liquid junction potential of 8 Ϯ 1 mV (n ϭ 6) was measured and taken into account according to Neher (1992).”
MethodAnion Permeation in Ca2+-Activated Cl− Channels
Qu, Z., & Hartzell, H. C. (2000) · The Journal of General Physiology · doi:10.1085/jgp.116.6.825 · Cited by 161
Crozier, R. A., Wang, Y., Liu, C.-H., & Bear, M. F. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609596104 · Cited by 163
Gasping Activity In Vitro : A Rhythm Dependent on 5-HT 2A Receptors
Tryba, A. K., Peña, F., & Ramirez, J.-M. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.4186-05.2006 · Cited by 167
“…important implications not only for SIDS but also sleep apnea, in which a reduction in 5-HT release during sleep (Fornal and Jacob, 1998) may decrease motor tone and patency of the upper airways, possibly by modulation of hypoglossal inspiratory activity (Kubin et al., 1996; Okabe and Kubin, 1996).”
BackgroundPei, Z. M., Ward, J. M., Harper, J. F., & Schroeder, J. I. (1996) · The EMBO Journal · doi:10.1002/j.1460-2075.1996.tb01047.x · Cited by 166
Substance P-Mediated Modulation of Pacemaker Properties in the Mammalian Respiratory Network
Peña, F., & Ramirez, J.-M. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.1871-04.2004 · Cited by 159
Functional Diversity of P-Type and R-Type Calcium Channels in Rat Cerebellar Neurons
Tottene, A., Moretti, A., & Pietrobon, D. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-20-06353.1996 · Cited by 164
“…that between the Tyrode’s solution in the experimental chamber and the external recording solution (flowing from the capillary tube) was 24 mV; these two junction potentials should be added to all voltages to obtain the correct values of membrane potential in whole-cell recordings (Neher, 1992).”
BackgroundInfluentialLupica, C. R., Bell, J. A., Hoffman, A. F., & Watson, P. L. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.86.1.261 · Cited by 170
Liu, P. W., & Bean, B. P. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.1925-13.2014 · Cited by 161
“Kv2 channels are subject to a remarkable range of modulatory influences that can alter functional expression (Misonou et al., 2004; O’Connell et al., 2010; Fox et al., 2013) through regulation by phosporylation (Murakoshi et al., 1997; Mohapatra et al., 2007; Cerda and Trimmer, 2011; Ikematsu et…”
BackgroundVoets, T., Manolopoulos, V., Eggermont, J., Ellory, C., Droogmans, G., & Nilius, B. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.341bw.x · Cited by 161
“In Cl¦ substitution experiments, a 3 Ò KCl—agar bridge was used and membrane voltages were corrected for liquid junction potentials as described by Neher (1992).”
MethodCell‐attached measurements of the firing threshold of rat hippocampal neurones
Fricker, D., Verheugen, J. A. H., & Miles, R. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0791s.x · Cited by 160
“In cell-attached recordings, the amplifier was set to zero with the recording pipette in the bath solution, to null the junction potential between the bath and the pipette solution (measured according to Neher (1992), this potential was 3 mV for a KCl-based solution).”
MethodPolyamines Are Potent Ligands for the Capsaicin Receptor TRPV1
Ahern, G. P., Wang, X., & Miyares, R. L. (2006) · Journal of Biological Chemistry · doi:10.1074/jbc.m513429200 · Cited by 159
Czempinski, K., Zimmermann, S., Ehrhardt, T., & Müller‐Röber, B. (1997) · The EMBO Journal · doi:10.1093/emboj/16.10.2565 · Cited by 159
“Hybridization was performed under were determined and corrected as described (Neher, 1992).”
MethodPower, J. M., Wu, W. W., Sametsky, E., Oh, M. M., & Disterhoft, J. F. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-16-07234.2002 · Cited by 158
“This junction potential was measured for every batch of electrode solution according to procedures published by Neher (1992) and was corrected before data acquisition.”
MethodAllen, G. J., & Sanders, D. (1995) · The Plant Cell · doi:10.2307/3870136 · Cited by 156
The Cation Selectivity Filter of the Bacterial Sodium Channel, NaChBac
Yue, L., Navarro, B., Ren, D., Ramos, A. J., & Clapham, D. E. (2002) · The Journal of General Physiology · doi:10.1085/jgp.20028699 · Cited by 173
“The liquid junction potentials were measured using a salt bridge as described by Neher (Neher, 1992) and these measurements agreed within 3 mV to those calculated by the JPCalc program (P. Barry) within Clampex (Axon Instruments, Inc.).”
MethodThe Selectivity Filter of the Cation Channel TRPM4
Nilius, B., Prenen, J., Janssens, A., Owsianik, G., Wang, C., Zhu, M. X., & Voets, T. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m501686200 · Cited by 172
Liu, G. X., Derst, C., Schlichthörl, G., Heinen, S., Seebohm, G., Brüggemann, A., Kummer, W., Veh, R. W., Daut, J., & Preisig‐Müller, R. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0115g.x · Cited by 180
“The data were not corrected for the liquid junction potential, which was +2.8 mV (determined as described by Neher, 1992).”
BackgroundInfluentialPotassium Currents during the Action Potential of Hippocampal CA3 Neurons
Mitterdorfer, J., & Bean, B. P. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-23-10106.2002 · Cited by 146
“All reported voltages are corrected for a liquid junction potential of 10 mV between the pipette solution and the Tyrode’s solution (in which the pipette current is zeroed before sealing onto a cell), measured as described by Neher (1992).”
MethodMalate‐sensitive anion channels enable guard cells to sense changes in the ambient CO2 concentration
Hedrich, R., Marten, I., Lohse, G., Dietrich, P., Sederoff, H. W., Lohaus, G., & Heldt, H. (1994) · The Plant Journal · doi:10.1046/j.1365-313x.1994.6050741.x · Cited by 153
Alternative Translation Initiation in Rat Brain Yields K2P2.1 Potassium Channels Permeable to Sodium
Thomas, D., Plant, L. D., Wilkens, C. M., McCrossan, Z. A., & Goldstein, S. A. N. (2008) · Neuron · doi:10.1016/j.neuron.2008.04.016 · Cited by 166
“Liquid junction potentials were measured on the Axopatch 200B at room temperature according to a method (Neher, 1992).”
Gunn, B. G., Cunningham, L., Cooper, M. A., Corteen, N. L., Seifi, M., Swinny, J. D., Lambert, J. J., & Belelli, D. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1337-13.2013 · Cited by 151
“A measured liquid junction potential of 11 mV was corrected as described previously (Neher, 1992).”
MethodAtherton, J. F., & Bevan, M. D. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.1475-05.2005 · Cited by 144
“A liquid junction potential correction was subtracted off-line from all recordings (Neher, 1992).”
MethodTottene, A., Pivotto, F., Fellin, T., Cesetti, T., van den Maagdenberg, A. M. J. M., & Pietrobon, D. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m501110200 · Cited by 151
Automated Parallel Recordings of Topologically Identified Single Ion Channels
Kawano, R., Tsuji, Y., Sato, K., Osaki, T., Kamiya, K., Hirano, M., Ide, T., Miki, N., & Takeuchi, S. (2013) · Scientific Reports · doi:10.1038/srep01995 · Cited by 157
Synaptic release of dopamine in the subthalamic nucleus
Cragg, S. J., Baufreton, J., Xue, Y., Bolam, J. P., & Bevan, M. D. (2004) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2004.03629.x · Cited by 169
“The value of the offset was smaller than the empirically calculated junction potential between the electrode solution and the external media of +9 mV (Neher, 1992; Barry, 1994).”
BackgroundA GABA transporter operates asymmetrically and with variable stoichiometry
Cammack, J. N., Rakhilin, S., & Schwartz, E. A. (1994) · Neuron · doi:10.1016/0896-6273(94)90260-7 · Cited by 148
“Changes in junction potential produced by an alteration in extracellular solutions were measured as described by Neher (1992), and the data were corrected.”
MethodMonier, C., Fournier, J., & Frégnac, Y. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.11.008 · Cited by 159
Wegner, L. H., & BOER, A. H. D. (1997) · PLANT PHYSIOLOGY · doi:10.1104/pp.115.4.1707 · Cited by 146
Schrader, L. A., & Tasker, J. G. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.77.2.527 · Cited by 143
“…fixed overnight a mean membrane potential, corrected for junction potentialat 47C in tris(hydroxymethyl)aminomethane-buffered saline with (Neher 1992), of 064 { 1 mV and a mean input resistance4% paraformaldehyde and 10% sucrose and cryosectioned at 15– of 999 { 63 MV.25 mm.…”
MethodMolecular Coupling of a Ca 2+ -Activated K + Channel to L-Type Ca 2+ Channels via α-Actinin2
Lü, L., Zhang, Q. Y., Timofeyev, V., Zhang, Z., Young, J. N., Shin, H., Knowlton, A. A., & Chiamvimonvat, N. (2006) · Circulation Research · doi:10.1161/01.res.0000253095.44186.72 · Cited by 145
Ephaptic coupling promotes synchronous firing of cerebellar purkinje cells
Han, K.-S., Guo, C., Chen, C. H., Witter, L., Osorno, T., & Regehr, W. G. (2018) · Neuron · doi:10.1016/j.neuron.2018.09.018 · Cited by 144
Ng, G., Bertrand, S. S., Sullivan, R. J., Éthier, N., Wang, J. P., Yergey, J. A., Belley, M. L., Trimble, L. A., Bateman, K. P., Alder, L., et al. (2001) · Molecular Pharmacology · doi:10.1124/mol.59.1.144 · Cited by 153
Zhang, Z., He, Y., Tuteja, D., Xu, D., Timofeyev, V., Zhang, Q., Glatter, K. A., Xu, Y., Shin, H., Low, R., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.540070 · Cited by 140
Calcium Channel Density and Hippocampal Cell Death with Age in Long-Term Culture
Porter, N. M., Thibault, O., Thibault, V., Chen, K.-C., & Landfield, P. W. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-14-05629.1997 · Cited by 142
“Furthermore, the diffusion and time to equilibrium between pipette solutions and cellular contents that result in junction potentials may be delayed in larger cells (Neher, 1992).”
BackgroundTight-Seal Whole-Cell Recording
Marty, A., & Neher, E. (1995) · Springer eBooks · doi:10.1007/978-1-4419-1229-9_2 · Cited by 172
Self-citationSodickson, D. L., & Bean, B. P. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-20-08153.1998 · Cited by 137
“Membrane potentials were corrected for a liquid junction potential (Neher, 1992) of 212 mV between the internal solution and Tyrode’s solution (in which the current was zeroed before a seal was obtained).”
MethodIonic mechanisms of autorhythmic firing in rat cerebellar Golgi cells
Elisabetta Cesana, L. F., Mapelli, J., & D'Angelo, E. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.110858 · Cited by 132
“The liquid junction potential (ELJ) between the bath and pipette solution was measured according to Neher (1992), and was 10 mV. ELJ has been subtracted from membrane potential (V m) measurements throughout the text.”
MethodThomas, S. P., Kucera, J. P., Bircher-Lehmann, L., Rudy, Y., Saffitz, J. E., & Kléber, A. G. (2003) · Circulation Research · doi:10.1161/01.res.0000074916.41221.ea · Cited by 134
Angulo, M. C., Lambolez, B., Audinat, E., Hestrin, S., & Rossier, J. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-17-06685.1997 · Cited by 136
“All potentials were corrected for junction potential (Ϫ12 mV) (Neher, 1992).”
Functional Organization of Cone Bipolar Cells in the Rat Retina
Hartveit, E. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.77.4.1716 · Cited by 136
Noninvasive Measurements of the Membrane Potential and GABAergic Action in Hippocampal Interneurons
Verheugen, J. A. H., Fricker, D., & Miles, R. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-07-02546.1999 · Cited by 135
“The junction potential between pipette and extracellular solution (,3 mV as measured according to Neher, 1992) was nulled by the voltage-offset of the amplifier (Axopatch 200A) before establishing the seal and was not further corrected.”
MethodStructure of the mammalian TRPM7, a magnesium channel required during embryonic development
Duan, J., Li, Z., Li, J., Hulse, R. E., Santa‐Cruz, A., Valinsky, W. C., Abiria, S. A., Krapivinsky, G. B., Zhang, J., & Clapham, D. E. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1810719115 · Cited by 139
“Currents were offline-corrected for liquid junction potential using previously described methods (64).”
MethodCav1.3 (α1D) Ca2+ Currents in Neonatal Outer Hair Cells of Mice
Michna, M., Knirsch, M., Hoda, J., Muenkner, S., Langer, P., Platzer, J., Striessnig, J., & Engel, J. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2003.053256 · Cited by 131
“Series resistance (Rs) compensation was only used when Rs was larger than 12 MV. Raw currents were corrected for linear leak currrents and potentials were corrected by _20 mV for liquid junction potentials (LJP) measured according to Neher (1992).”
MethodSchulz‐Lessdorf, B., & Hedrich, R. (1995) · Planta · doi:10.1007/bf00191574 · Cited by 144
Membrane depolarization in PC-12 cells during hypoxia is regulated by an O2-sensitive K+ current
Zhu, W., Conforti, L., Czyzyk-Krzeska, M., & Millhorn, D. E. (1996) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1996.271.2.c658 · Cited by 134
Lahiri, A. K., & Bevan, M. D. (2020) · Neuron · doi:10.1016/j.neuron.2020.01.028 · Cited by 133
“This is slightly less than the estimated liquid junction potential of 8.7 mV between the internal and external solutions (Barry, 1994; Neher, 1992).”
BackgroundInfluentialWarm Body Temperature Facilitates Energy Efficient Cortical Action Potentials
Yu, Y., Hill, A. P., & McCormick, D. A. (2012) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1002456 · Cited by 130
“The membrane potential in our whole cell recordings was corrected for Donnan liquid junction potentials of 10 mV [54,55].”
MethodEhrengruber, M. U., Hennou, S., Büeler, H., Naim, H. Y., Déglon, N., & Lundstrom, K. H. (2001) · Molecular and Cellular Neuroscience · doi:10.1006/mcne.2001.0982 · Cited by 150
Vandenberg, J. I., Yoshida, A., Kirk, K., & Powell, T. L. (1994) · The Journal of General Physiology · doi:10.1085/jgp.104.6.997 · Cited by 132
Hájos, N., & Mody, I. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-21-08427.1997 · Cited by 131
“The liquid junction potential was reduced using an agar bridge (Neher, 1992).”
Welsh, D. G., Nelson, M. T., Eckman, D. M., & Brayden, J. E. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00139.x · Cited by 131
“Liquid junction potentials were measured as previously described (Neher, 1992) and were less than 2 mV with any solution change.”
MethodRegulated Exocytosis of GABA-containing Synaptic-like Microvesicles in Pancreatic β-cells
Braun, M., Wendt, A., Birnir, B., Broman, J., Eliasson, L., Galvanovskis, J., Gromada, J., Mulder, H., & Rorsman, P. (2004) · The Journal of General Physiology · doi:10.1085/jgp.200308966 · Cited by 130
“Liquid junction potentials (V LJ ) were measured according to Neher (1992).”
Hadjinicolaou, A. E., Leung, R. T., Garrett, D. J., Ganesan, K., Fox, K. E., Nayagam, D. A. X., Shivdasani, M. N., Meffin, H., Ibbotson, M. R., Prawer, S., et al. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.04.063 · Cited by 133
Modulation of a pacemaker current through Ca2+-induced stimulation of cAMP production
Lüthi, A., & McCormick, D. A. (1999) · Nature Neuroscience · doi:10.1038/10189 · Cited by 145
Spatial Organization of Calcium Signaling Involved in Cell Volume Control in the Fucus Rhizoid
Taylor, A. R., Manison, N. F. H., Fernandez, C., Wood, J., & Brownlee, C. (1996) · The Plant Cell · doi:10.2307/3870409 · Cited by 130
Viemari, J., & Ramirez, J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01308.2005 · Cited by 129
“All membrane potential values were corrected for this LJP as described by Neher (1992).”
MethodDu, X., Hao, H., Gigout, S., Huang, D., Yang, Y., Li, L., Wang, C., Sundt, D., Jaffe, D. B., Zhang, H., et al. (2014) · Pain · doi:10.1016/j.pain.2014.08.025 · Cited by 139
“Because liquid junction potential should be <1 mV [89], no correction was applied.”
BackgroundMethodThoby-Brisson, M., Telgkamp, P., & Ramirez, J.-M. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-08-02994.2000 · Cited by 131
“All membrane potential measurements were therefore compensated for this LJP as described by Neher (1992).”
MethodSchumacher, T. B., Beck, H., Steinhäuser, C., Schramm, J., & Elger, C. E. (1998) · Epilepsia · doi:10.1111/j.1528-1157.1998.tb01387.x · Cited by 139
Okazaki, M. M., Molnár, P., & Nadler, J. V. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.4.1645 · Cited by 130
Voltage‐dependent calcium‐permeable channels in the plasma membrane of a higher plant cell.
Thuleau, P., Ward, J. M., Ranjeva, R., & Schroeder, J. I. (1994) · The EMBO Journal · doi:10.1002/j.1460-2075.1994.tb06595.x · Cited by 128
Afterhyperpolarization Regulates Firing Rate in Neurons of the Suprachiasmatic Nucleus
Cloues, R. K., & Sather, W. A. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-05-01593.2003 · Cited by 126
“5 mV was measured for the solutions used in current-clamp recording (Neher, 1992); data were not adjusted for this junction potential.”
Coherent phasic excitation during hippocampal ripples
Maier, N., Tejero-Cantero, Á., Dorrn, A. L., Winterer, J., Beed, P. S., Morris, G., Kempter, R., Poulet, J. F. A., Leibold, C., & Schmitz, D. (2011) · Neuron · doi:10.1016/j.neuron.2011.08.016 · Cited by 126
“Voltages were liquid junction potential-corrected (experimentally determined; Neher, 1992).”
BackgroundMaccaferri, G., & Dingledine, R. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-13-05462.2002 · Cited by 121
“Membrane potentials recorded in current clamp have been corrected for a junction potential between intracellular and extracellular solution, which was experimentally measured to be 10 mV (Neher, 1992).”
MethodKimm, T., Khaliq, Z. M., & Bean, B. P. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.5291-14.2015 · Cited by 122
Di, S., Boudaba, C., Popescu, I. R., Weng, F., Harris, C., Marcheselli, V. L., Bazan, N. G., & Tasker, J. G. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.097477 · Cited by 118
“The electrode liquid junction potential was 11 mV and was compensated for following recordings (Neher, 1992).”
BackgroundBaufreton, J., Garret, M., Rivera, A., de la Calle, A., Gonon, F., DUFY, B., Bioulac, B. H., & Taupignon, A. (2003) · Journal of Neuroscience · doi:10.1523/jneurosci.23-03-00816.2003 · Cited by 129
“Junction potentials were measured according to the method described by Neher (1992), and voltage errors were corrected off-line.”
MethodPiñeros, M. A., Cançado, G. M. D. A., Maron, L., Lyi, S. M., Menossi, M., & Kochian, L. V. (2007) · The Plant Journal · doi:10.1111/j.1365-313x.2007.03344.x · Cited by 140
“Liquid junction potentials were measured and corrected according to the method described by Neher (1992).”
MethodStructure and Mechanism of Kainate Receptor Modulation by Anions
Plested, A. J. R., & Mayer, M. L. (2007) · Neuron · doi:10.1016/j.neuron.2007.02.025 · Cited by 137
Serial inhibitory synapses in retina
Zhang, J., Jung, C.-S., & Slaughter, M. M. (1997) · Visual Neuroscience · doi:10.1017/s0952523800012219 · Cited by 122
P2Z purinoceptor-associated pores induced by extracellular ATP in macrophages and J774 cells
Coutinho-Silva, R., & Persechini, P. M. (1997) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1997.273.6.c1793 · Cited by 119
Parri, H. R., & Crunelli, V. (1998) · Journal of Neuroscience · doi:10.1523/jneurosci.18-03-00854.1998 · Cited by 122
“All potential values quoted in the text and figures have been corrected for liquid junction potentials (Barry and Lynch, 1991; Neher, 1992): 211 and 28 mV for low (20 mM) and high (130 mM) Na 1 solution, respectively, calculated using Axoscope (Axon Instruments).”
Giocomo, L. M., & Hasselmo, M. E. (2009) · Journal of Neuroscience · doi:10.1523/jneurosci.0609-09.2009 · Cited by 117
“The liquid junction potential was 5 mV, measured using the technique of Neher (1992).”
MethodMott, D. D., Turner, D. A., Okazaki, M. M., & Lewis, D. V. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-11-03990.1997 · Cited by 121
“Although a junction potential of ;10 mV has been reported using the pipette solution used in this study (Neher, 1992; Staley and Mody, 1992; Kawa, 1994), the potentials given in the tables have not been corrected for a junction potential.”
Cato, M. J., & Toney, G. M. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01055.2003 · Cited by 123
Lemtiri‐Chlieh, F., & Berkowitz, G. A. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m400311200 · Cited by 130
Differential modulation of Ih by 5‐HT receptors in mouse CA1 hippocampal neurons
Bickmeyer, U., Heine, M., Manzke, T., & Richter, D. W. (2002) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2002.02072.x · Cited by 116
“A liquid junction potential of 4 mV was measured according to Neher (1992), but data were not corrected.”
MethodSchmidt, C., & Schroeder, J. I. (1994) · PLANT PHYSIOLOGY · doi:10.1104/pp.106.1.383 · Cited by 120
Tabcharani, J. A., Linsdell, P., & Hanrahan, J. W. (1997) · The Journal of General Physiology · doi:10.1085/jgp.110.4.341 · Cited by 118
“M KCl electrode (Neher, 1992) and reported voltages have been corrected accordingly.”
MethodCold Transiently Activates Calcium-Permeable Channels in Arabidopsis Mesophyll Cells
Carpaneto, A., Ivashikina, N., Levchenko, V., Krol, E., Jeworutzki, E., Zhu, J., & Hedrich, R. (2006) · PLANT PHYSIOLOGY · doi:10.1104/pp.106.090928 · Cited by 118
“The command voltages were corrected off-line for liquid junction potential (Neher, 1992).”
BackgroundQian, Z., Okuhara, D. Y., Abe, M. K., & Rosner, M. R. (1999) · Journal of Biological Chemistry · doi:10.1074/jbc.274.3.1621 · Cited by 117
Mechanism of Auxiliary Subunit Modulation of Neuronal α1E Calcium Channels
Jones, L. P., Wei, S.-K., & Yue, D. T. (1998) · The Journal of General Physiology · doi:10.1085/jgp.112.2.125 · Cited by 117
“In all cases, the junction potential between external and internal solutions was z5 mV (Neher, 1992).”
BackgroundBeurrier, C., Bioulac, B. H., & Hammond, C. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.4.1951 · Cited by 117
“The correction was26 mV for the K-gluconate-based pipette solution as estimated with a 3 M KCl ground electrode (Neher 1992).”
MethodElectrodiffusion phenomena in neuroscience: a neglected companion
Savtchenko, L. P., Poo, M. M., & Rusakov, D. A. (2017) · Nature reviews. Neuroscience · doi:10.1038/nrn.2017.101 · Cited by 131
Rosenkranz, J. A., & Johnston, D. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.4333-05.2006 · Cited by 115
“The liquid junction potential between the intracellular and extracellular solutions was also measured to be 3– 4 mV using the method described by Neher (1992), suggesting that this difference between measured and actual membrane potentials may be even less.”
MethodBrody, D. L., Patil, P. G., Mullé, J. G., Snutch, T. P., & Yue, D. T. (1997) · The Journal of Physiology · doi:10.1113/jphysiol.1997.sp021956 · Cited by 115
Giocomo, L. M., & Hasselmo, M. E. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3196-08.2008 · Cited by 109
“For all solutions, the liquid junction potential was estimated between 5 and 6 mV using the technique of Neher (1992) and Dickson et al. (2000).”
MethodPennartz, C. M. A., De Jeu, M. T. G., Geurtsen, A. M. S., Sluiter, A. A., & Hermes, M. L. H. J. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.775bv.x · Cited by 114
“All voltage measurements were corrected for the liquid junction potential, which amounted to −13 mV as determined according to the method described by Neher (1992).”
MethodSzinyei, C., Heinbockel, T., Montagne, J., & Pape, H.-C. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-23-08909.2000 · Cited by 110
“Liquid junction potentials in all voltage-clamp experiments were corrected (Neher, 1992).”
MethodDoan, T. N., & Kunze, D. L. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.125af.x · Cited by 115
“For data presented, the voltage error did not exceed ±3 mV. Junction potentials were corrected as described by Nehr (1992).”
MethodPennartz, C. M. A., Bierlaagh, M. A., & Geurtsen, A. M. S. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.4.1811 · Cited by 113
Budde, T., Caputi, L., Kanyshkova, T. G., Staak, R., Abrahamczik, C., Munsch, T., & Pape, H. (2005) · Journal of Neuroscience · doi:10.1523/jneurosci.2590-05.2005 · Cited by 127
“A liquid junction potential of 10 1 mV (n 6) was measured and taken into account (Neher, 1992).”
MethodYu, G.-H., Zou, J., Feng, J. Q., Peng, X., Wu, J.-Y., Wu, Y.-L., Palanivelu, R., & Sun, M.-X. (2014) · Journal of Experimental Botany · doi:10.1093/jxb/eru171 · Cited by 111
“The membrane was held at a holding potential of 0 mV and liquid junction potentials were corrected according to a previous method (Neher, 1992; Wu et al., 2011).”
MethodFunctional Roles of a Ca 2+ -Activated K + Channel in Atrioventricular Nodes
Zhang, Q., Timofeyev, V., Lü, L., Li, N., Singapuri, A., Long, M., Bond, C. T., Adelman, J. P., & Chiamvimonvat, N. (2007) · Circulation Research · doi:10.1161/circresaha.107.161778 · Cited by 110
Optogenetically induced sleep spindle rhythms alter sleep architectures in mice
Kim, A., Latchoumane, C., Lee, S., Kim, G. B., Cheong, E., Augustine, G. J., & Shin, H.-S. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1217897109 · Cited by 102
Metadata
- Authors
- Neher, E.
- Affiliations
- Max Planck Society (DE)
- Corresponding author
- Neher, Erwin
- ORCID
- Neher, Erwin
- Venue
- Methods in Enzymology
- Publisher
- Elsevier
- Published
- 1992
- Volume
- 207
- Pages
- 123-131
- ISSN
- 0076-6879 (ISSN-L)
- OpenAlex
- W1561818412
- Cited by
- 1,132
- References
- 6
- Citations by year
- 2026: 14 · 2025: 17 · 2024: 11 · 2023: 13 · 2022: 19 · 2021: 19 · 2020: 35 · 2019: 26 · 2018: 25 · 2017: 21 · 2016: 24 · 2015: 29 · 2014: 25 · 2013: 31 · 2012: 28
- FWCI
- 27.85
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- Methods in enzymology on CD-ROM/Methods in enzymology (publishedVersion)
- PubMed (publishedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- liquid junction potential, patch clamp, reference electrode, Ag/AgCl electrodes, salt bridges, microperfusion
- MeSH terms
- Amplifiers, Electronic, Electrophysiology, Membrane Potentials, Microelectrodes, Potentiometry, Solutions, Artifacts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.