[6] Correction for liquid junction potentials in patch clamp experiments
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This chapter describes corrections that have to be applied to measured membrane potentials in patch clamp experiments. Some of them [Eqs. (1)-(3)] are required regardless of the nature of the reference electrode (in the Ringer's solution bath) whenever the pipette-filling solution is different from the bath solution. They represent the liquid junction potentials that are present at the pipette tip before patch formation. In addition, corrections have to be applied when the bath solution is being changed during a measurement (i.e., after seal formation). In that case the following rules apply. (1) The new solution should never get into contact with the bare silver/silver chloride wire of the reference electrode. This requirement is best met by using a salt bridge. (2) The "best" salt bridge is a 3 M KCl bridge with an abrupt KCl-bath fluid boundary at its tip (see above). This bridge does not require any additional potential corrections, but it may lead to KCl poisoning of the bath or become contaminated by solutions used previously. (3) Local solution changes (microperfusion by puffer pipette, U tool or sewer pipe arrangements) as well as recessed KCl bridges require additional corrections, which (together with the simple liquid junction potential correction) are approximately given by Eqs. (6)-(8). It should be stressed that all equations given here represent approximate corrections, since liquid junction potentials are thermodynamically ill-defined. This is particularly relevant for Eqs. (6) and (7) where the sum of two liquid junction potentials appears.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Automated reconstructions were then extensively manually corrected and curated using a range of tools (e.g., virtual finger, polyline) in the Mozak extension (Zoran Popovic, Center for Game Science, University of Washington) of Terafly tools50,53 in Vaa3D.”
From Classification of electrophysiological and morphological neuron types in the mouse visual cortex (2019) · cites this paper as [50]
Citations
Cites
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Self-citationAshcroft, F. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90114-3 · Cited by 982
A patch-clamp study of bovine chromaffin cells and of their sensitivity to acetylcholine
Fenwick, E. M., Marty, A., & Neher, E. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014393 · Cited by 812
Self-citationRates of diffusional exchange between small cells and a measuring patch pipette
Pusch, M., & Neher, E. (1988) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00582316 · Cited by 703
Self-citationLiquid junction potentials and small cell effects in patch-clamp analysis
Barry, P. H., & Lynch, J. W. (1991) · The Journal of Membrane Biology · doi:10.1007/bf01870526 · Cited by 672
Barry, P. H., & Diamond, J. M. (1970) · The Journal of Membrane Biology · doi:10.1007/bf01868010 · Cited by 201
Research works printed but not linked: 2
- P. H. Barry, this series, Vol. 171, p. 678.
- Bockris, 1970, Vol. 1.
Cited by
Items 501–600 of 1,002
Neuromodulation of Ih in Layer II Medial Entorhinal Cortex Stellate Cells: A Voltage-Clamp Study
Heys, J. G., & Hasselmo, M. E. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.0868-12.2012 · Cited by 44
“Liquid junction potential was measured to be between 5 and 6 mV using the technique of Neher (1992) and Dickson et al. (2000).”
MethodLi, W., Zuo, W., Wu, W., Zuo, Q., Fu, R., Wu, L., Zhang, H., Ndukwe, M., & Ye, J.-H. (2019) · Neuropharmacology · doi:10.1016/j.neuropharm.2019.107688 · Cited by 43
“A liquid junction potential correction was subtracted off-line from all recordings (Pages 123–131 at Neher (1992).”
MethodRegulation of the V-type ATPase by redox modulation
Seidel, T., Scholl, S., Krebs, M., Rienmüller, F., Marten, I., Hedrich, R., Hanitzsch, M., Janetzki, P., Dietz, K., & Schumacher, K. (2012) · Biochemical Journal · doi:10.1042/bj20120976 · Cited by 40
Permeant Anions Control Gating of Calcium-dependent Chloride Channels
Pérez‐Cornejo, P., de Santiago, J. A., & Arreola, J. (2004) · The Journal of Membrane Biology · doi:10.1007/s00232-004-0659-x · Cited by 40
“tentials of +6 mV were experimentally determined (Neher, 1992)”
Wilson, J. R., Duncan, N. A., Giles, W. R., & Clark, R. B. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.058883 · Cited by 40
“Use of unequal [Cl−] in the patch pipette and bath solution (see below) produced a liquid junction potential which resulted in an approximately +10 mV offset of the recorded membrane potentials (Neher, 1992).”
BackgroundSibarov, D. A., Abushik, P. A., Poguzhelskaya, E. E., Bolshakov, K. V., & Antonov, S. M. (2015) · Journal of Pharmacology and Experimental Therapeutics · doi:10.1124/jpet.115.227173 · Cited by 40
“For NMDA 1 Gly 1 KBR, the control was measured in the external bathing solution 1 KBR. I-V relationships and membrane holding voltages were corrected for the liquid junction potential (approximately 215 mV; see Neher, 1992).”
MethodIon channels in the vacuoles of the seagrassPosidonia oceanica
Carpaneto, A., Cantù, A. M., Busch, H., & Gambale, F. (1997) · FEBS Letters · doi:10.1016/s0014-5793(97)00786-2 · Cited by 40
Bai, D., & Renaud, L. P. (1998) · Neuroscience · doi:10.1016/s0306-4522(97)00435-1 · Cited by 45
Mori, A., Takahashi, T., Miyashita, Y., & Kasai, H. (1994) · The Journal of Physiology · doi:10.1113/jphysiol.1994.sp020125 · Cited by 44
Mechanisms Shaping the Slow Nicotinic Synaptic Current at the Motoneuron-Renshaw Cell Synapse
d’Incamps, B. L., Krejci, É., & Ascher, P. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.0181-12.2012 · Cited by 43
“Membrane potentials were corrected for the liquid junction potential (Vj 15 mV) measured as indicated by Neher (1992).”
MethodLiu, P. W., Blair, N. T., & Bean, B. P. (2017) · Journal of Neuroscience · doi:10.1523/jneurosci.1703-17.2017 · Cited by 41
Electrodiffusion Phenomena in Neuroscience and the Nernst–Planck–Poisson Equations
Jasielec, J. J. (2021) · Electrochem · doi:10.3390/electrochem2020014 · Cited by 44
“The analysis of the time-dependent LJP response is also important for the practical applications in methods of analytical potentiometry, such as patch-clamp analysis [81] or fully automatic clinical electrolyte analyzers [82–84].”
MethodViemari, J., Garcia, A. J., Doi, A., Elsen, G. E., & Ramirez, J. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2013.00179 · Cited by 39
KATPchannel conductance of descending vasa recta pericytes
Cao, C., Lee‐Kwon, W., Silldorff, E. P., & Pallone, T. L. (2005) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00111.2005 · Cited by 40
“All data have been corrected for junction potentials (39, 45, 46).”
Yu, B., & Shinnick-Gallagher, P. (1998) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(24)37223-4 · Cited by 39
Takahata, T., Hayashi, M., & Ishikawa, T. (2003) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00250.2002 · Cited by 39
Liu, J., & Misler, S. (1998) · Journal of Neuroscience · doi:10.1523/jneurosci.18-16-06113.1998 · Cited by 41
“This “threshold value” of cytosolic Ca resembles that seen when patchclamped chromaffin cells are dialyzed with patch pipette solutions of known Ca concentration (Augustine and Neher, 1992).”
BackgroundMethodInfluentialWegner, L. H., & BOER, A. H. D. (1997) · Planta · doi:10.1007/s004250050220 · Cited by 39
Papp, Z. L., Sipido, K. R., Callewaert, G., & Carmeliet, E. E. (1995) · The Journal of Physiology · doi:10.1113/jphysiol.1995.sp020588 · Cited by 39
Blind patch clamp recordings in embryonic and adult mammalian brain slices
Castañeda-Castellanos, D. R., Flint, A. C., & Kriegstein, A. R. (2006) · Nature Protocols · doi:10.1038/nprot.2006.75 · Cited by 44
A Unifying Mechanism for Cancer Cell Death through Ion Channel Activation by HAMLET
Storm, P., Klausen, T. K., Trulsson, M., Ho, J. C. S., Dosnon, M., Westergren, T., Chao, Y., Rydström, A., Yang, H. H., Pedersen, S. F., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0058578 · Cited by 42
“Before calculations, Vrev was corrected for liquid junction potentials [31] (VLJ) as:”
Presynaptic Inhibition of Primary Nociceptive Signals to Dorsal Horn Lamina I Neurons by Dopamine
Lu, Y., Doroshenko, M., Lauzadis, J., Kanjiya, M. P., Rebecchi, M. J., Kaczocha, M., & Puopolo, M. (2018) · Journal of Neuroscience · doi:10.1523/jneurosci.0323-18.2018 · Cited by 39
Acid‐sensing ion channels in neurones of the rat suprachiasmatic nucleus
Chen, C., Hsu, Y., Chen, C., & Huang, R. (2009) · The Journal of Physiology · doi:10.1113/jphysiol.2008.166918 · Cited by 38
“The measured liquid junction potential was −12 mV (Neher, 1992) and was corrected for in the presentation of data.”
MethodBot, C. T., Kherlopian, A. R., Ortega, F. A., Christini, D. J., & Krogh‐Madsen, T. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00421 · Cited by 41
“For statistical analysis,we used”
Almog, M., & Korngreen, A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004841 · Cited by 42
“voltage offset due to electrode and liquid junction potentials [21] was measured as 211 mV.”
Johansson, S., Druzin, M., Haage, D., & Wang, M. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0625e.x · Cited by 38
“The liquid-junction potential was measured as described by Neher (1992) and has been subtracted from all potential values given.”
MethodThomine, S., Guern, J., & Barbier‐Brygoo, H. (1997) · The Journal of Membrane Biology · doi:10.1007/s002329900270 · Cited by 38
“The liquid junction potential was measured according to Neher (1992).”
MethodHayashi, M., Kunii, C., Takahata, T., & Ishikawa, T. (2004) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00283.2003 · Cited by 38
de la Prida, L. M., & Gal, B. (2004) · Journal of Neuroscience · doi:10.1523/jneurosci.0309-04.2004 · Cited by 39
“The junction potential ( 7 mV for K-based solution and 10 mV for Cs-based solution) was corrected (Neher, 1994).”
BackgroundCa 2+ -Induced Current Oscillations in Rabbit Ventricular Myocytes
Laflamme, M. A., & Becker, P. L. (1996) · Circulation Research · doi:10.1161/01.res.78.4.707 · Cited by 38
Trommer, B. L., Liu, Y.-B., & Pasternak, J. F. (1996) · Developmental Brain Research · doi:10.1016/0165-3806(96)00104-6 · Cited by 40
Amakhin, D. V., Malkin, S. L., Ergina, J. L., Kryukov, K. A., Veniaminova, E. A., Zubareva, O. E., & Zaitsev, A. V. (2017) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2017.00264 · Cited by 38
“The liquid junction potential was estimated as described previously (Neher, 1992), and the holding potential was compensated offline for voltage-clamp recordings by subtracting 7mV.”
MethodTwo‐pore domain K+ channels regulate membrane potential of isolated human articular chondrocytes
Clark, R. B., Kondo, C. S., Belke, D. D., & Giles, W. R. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2011.210757 · Cited by 37
“Ten millivolts was subtracted from membrane potentials recorded by the patch-clamp amplifier in order to compensate for the liquid junction potential between the bath and pipette solutions (Neher, 1992).”
MethodÁlvarez, Y. D., Ibañez, L. I., Uchitel, O. D., & Marengo, F. D. (2007) · Cell Calcium · doi:10.1016/j.ceca.2007.04.014 · Cited by 37
Steinhausen, K., Stumpff, F., Strauß, O., Thieme, H., & Wiederholt, M. (2000) · Experimental Eye Research · doi:10.1006/exer.1999.0785 · Cited by 37
Hogg, D. W., Pamenter, M. E., Dukoff, D. J., & Buck, L. T. (2015) · The Journal of Physiology · doi:10.1113/jp270474 · Cited by 43
Activation of Bestrophin Cl– Channels Is Regulated by C-terminal Domains
Qu, Z. Q., Yu, K., Cui, Y., Ying, C., & Hartzell, C. (2007) · Journal of Biological Chemistry · doi:10.1074/jbc.m701043200 · Cited by 37
Wang, H., & Huang, R. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00061.2004 · Cited by 41
“The measured liquid junction potential was Ϫ17 mV (Neher 1992) and was not corrected for in the measurements of voltages.”
Jackson, A. C., & Bean, B. P. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.0935-07.2007 · Cited by 39
“Reported membrane potentials are corrected for a liquid junction potential of 8 mV between the internal solution and the Tyrode’s solution in which current was zeroed before sealing onto the cell, measured using a flowing 3 M KCl reference electrode (Neher, 1992).”
MethodA short motif in the C‐terminus of mouse bestrophin 4 inhibits its activation as a Cl channel
Qu, Z., Cui, Y., & Hartzell, C. (2006) · FEBS Letters · doi:10.1016/j.febslet.2006.03.025 · Cited by 37
“Electrophysiology Recordings were performed at 22–24 C using the whole-cell configuration of the patch clamp [6].”
MethodShi, W., & Zhang, X.-X. (2003) · Journal of Pharmacology and Experimental Therapeutics · doi:10.1124/jpet.102.046359 · Cited by 39
“A similar junction potential was reported by previous studies using similar solutions (e.g., Neher, 1992).”
ResultBretschneider, F., Wrisch, A., Lehmann‐Horn, F., & Grissmer, S. (1999) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.1999.00659.x · Cited by 37
“Liquid junction potentials measured as described by Neher (1992) were 3 mV and were not corrected for.”
MethodRole of the Na+/K+‐ATPase in regulating the membrane potential in rat peritoneal mast cells
Friis, U. G., Prætorius, H. A., Knudsen, T., & Johansen, T. (1997) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0701414 · Cited by 37
“The liquid junction potential between the normal internal and external solution was about 10 mV, mainly because of the di erent mobilities of the Cl7 and glutamate anions (Neher, 1992).”
BackgroundCrivellaro, G., Tottene, A., Vitale, M., Melone, M., Casari, G., Conti, F., Santello, M., & Pietrobon, D. (2021) · Neurobiology of Disease · doi:10.1016/j.nbd.2021.105419 · Cited by 37
“Liquid junction potentials (LJP) measured at the pipette tip was − 10 mV; this value should be added to all voltages to obtain the correct membrane potentials (Neher, 1992).”
Yang, N. J., Isensee, J., Neel, D. V., de Quadros, A. U., Zhang, H.-X. B., Lauzadis, J., Liu, S. M., Shiers, S. I., Belu, A., Palan, S., et al. (2021) · Nature Neuroscience · doi:10.1038/s41593-021-00973-8 · Cited by 39
Membrane Properties Related to the Firing Behavior of Zebrafish Motoneurons
Buss, R. R., Bourque, C. W., & Drapeau, P. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00324.2002 · Cited by 35
“A liquid junction potential of –10 mV was experimentally determined according to (Barry and Lynch 1991; Neher 1992) and records were corrected for this potential.”
MethodGreenwood, I. A., & Large, W. A. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0365v.x · Cited by 36
Qiu, D., Shirasaka, T., Chu, C.-P., Watanabe, S., Yu, N.-S., Katoh, T., & Kannan, H. (2003) · Neuroscience Letters · doi:10.1016/j.neulet.2003.11.002 · Cited by 39
Female Snake Sex Pheromone Induces Membrane Responses in Vomeronasal Sensory Neurons of Male Snakes
Huang, G., Zhang, J.-J., Wang, D., Mason, R. T., & Halpern, M. (2006) · Chemical Senses · doi:10.1093/chemse/bjj056 · Cited by 38
“Liquid junction potentials were measured with a microelectrode containing 3MKCl (Neher, 1992).”
MethodGunn, B. G., Cox, C. D., Chen, Y., Frotscher, M., Gall, C. M., Baram, T. Z., & LYNCH, G. S. (2017) · Cerebral Cortex · doi:10.1093/cercor/bhx103 · Cited by 40
“A liquid junction potential of 14mV was corrected for in the recordings as previously described (Neher 1992).”
MethodMechanisms of coronary artery depolarization by uridine triphosphate
Welsh, D. G., & Brayden, J. E. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.280.6.h2545 · Cited by 36
“Liquid junction potentials were measured as previously described (27) and were ,2 mV with any solution change.”
MethodIsoforms of α1E voltage-gated calcium channels in rat cerebellar granule cells
Schramm, M., Vajna, R., Pereverzev, A., Tottene, A., Klöckner, U., Pietrobon, D., Hescheler, J., & Schneider, T. (1999) · Neuroscience · doi:10.1016/s0306-4522(99)00013-5 · Cited by 36
Sørensen, J. B., Nielsen, M. S., Gudme, C. N., Larsen, E. H., & Nielsen, R. L. (2001) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240000493 · Cited by 36
Sandler, V. M., & Ross, W. N. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.1.216 · Cited by 40
Puopolo, M., & Belluzzi, O. (2001) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2001.01365.x · Cited by 36
Chiou, L. (1999) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0702746 · Cited by 36
“A liquid junction potential of 11 mV was corrected in o -line analysis (Neher, 1992).”
MethodSleep pressure accumulates in a voltage-gated lipid peroxidation memory
Rorsman, H. O., Müller, M. A., Liu, P. Z., Sanchez, L. G., Kempf, A., Gerbig, S., Spengler, B., & Miesenböck, G. (2025) · Nature · doi:10.1038/s41586-025-08734-4 · Cited by 36
Bigiani, A., & Cuoghi, V. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00716.2007 · Cited by 35
Qiu, D., Chu, C.-P., Shirasaka, T., Tsukino, H., Nakao, H., Kato, K., Kunitake, T., Katoh, T., & Kannan, H. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01325.2004 · Cited by 35
“The liquid junction potential (10 mV) was corrected according to the method described by Neher (1992).”
MethodSPONTANEOUS CA 2+ ACTIVATED CL − CURRENTS IN ISOLATED URETHRAL SMOOTH MUSCLE CELLS
Sergeant, G. P., Hollywood, M. A., McHale, N. G., & Thornbury, K. D. (2001) · The Journal of Urology · doi:10.1016/s0022-5347(05)65939-3 · Cited by 35
Characterization of Angiotensin II-regulated K+ Conductance in Rat Adrenal Glomerulosa Cells
Lotshaw, D. P. (1997) · The Journal of Membrane Biology · doi:10.1007/s002329900206 · Cited by 36
Lamas, J. A., Romero, M., Reboreda, A., Sánchez, E., & Ribeiro, S. J. (2009) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-009-0648-0 · Cited by 35
Hodgkin-Huxley analysis of a GCAC1 anion channel in the plasma membrane of guard cells
Kolb, H. ‐., Marten, I., & Hedrich, R. (1995) · The Journal of Membrane Biology · doi:10.1007/bf00233947 · Cited by 35
Qiu, D., Chu, C.-P., Shirasaka, T., Nabekura, T., Kunitake, T., Kato, K., Nakazato, M., Katoh, T., & Kannan, H. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00225.2003 · Cited by 37
Pau, D., Workman, A. J., Kane, K. A., & RANKIN, A. C. (2003) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0705553 · Cited by 44
Postnatal Development of Membrane Excitability in Taste Cells of the Mouse Vallate Papilla
Bigiani, A., Cristiani, R., Fieni, F., Ghiaroni, V., Bagnoli, P., & Pietra, P. (2002) · Journal of Neuroscience · doi:10.1523/jneurosci.22-02-00493.2002 · Cited by 35
“Leakage and capacitive currents were not subtracted from currents under voltage clamp, and all voltages have been corrected for liquid junction potential (LJP) ( 4 mV for KCl pipette solution and 10 mV for potassium gluconate pipette solution) (Neher, 1992).”
BackgroundFrachisse, J., Colcombet, J., Guern, J., & Barbier‐Brygoo, H. (2000) · The Plant Journal · doi:10.1046/j.1365-313x.2000.00689.x · Cited by 35
Strauß, O., Wiederholt, M., & Wienrich, M. (1996) · The Journal of Membrane Biology · doi:10.1007/s002329900069 · Cited by 35
Djouder, N., Prepens, U., Aktories, K., & Cavalié, A. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m001425200 · Cited by 35
Thio, L. L., Shanmugam, A., Isenberg, K. E., & Yamada, K. A. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00612.2002 · Cited by 37
“All holding potentials were corrected for junction potentials, which were measured empirically for each pipette solution (Neher 1992).”
MethodCalcium channel dysfunction in inferior colliculus neurons of the genetically epilepsy-prone rat
N’Gouemo, P., Faingold, C. L., & Morad, M. (2008) · Neuropharmacology · doi:10.1016/j.neuropharm.2008.11.005 · Cited by 34
“A liquid junction potential between the intracellular and extracellular solutions of ~11 mV, measured under current clamp mode (Neher 1992) and calculated with Clampex, was corrected off-line.”
MethodWegner, L. H., Flickinger, B., Eing, C., Berghöfer, T., Hohenberger, P., Frey, W., & Nick, P. (2011) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2011.01.016 · Cited by 35
“Liquid junction potentials were corrected for using the procedure of Neher [24].”
MethodVolume-Regulated Anion and Organic Osmolyte Channels in Mouse Zygotes1
Kolajova, M., & Baltz, J. M. (1999) · Biology of Reproduction · doi:10.1095/biolreprod60.4.964 · Cited by 34
Pathway-specificity in N-methyl-d-aspartate receptor-mediated synaptic inputs onto subplate neurons
Hirsch, S. J., & Luhmann, H. J. (2008) · Neuroscience · doi:10.1016/j.neuroscience.2008.01.068 · Cited by 37
Identification of K+ Channels in the Plasma Membrane of Maize Subsidiary Cells
Majore, I., Wilhelm, B., & Marten, I. (2002) · Plant and Cell Physiology · doi:10.1093/pcp/pcf104 · Cited by 34
“The clamped voltages were corrected for the liquid junction potential (Neher 1992).”
BackgroundChakraborty, S., Elvezio, V., Kaczocha, M., Rebecchi, M. J., & Puopolo, M. (2017) · The Journal of Physiology · doi:10.1113/jp273455 · Cited by 35
“Reported voltages for spontaneous and evoked EPSCs were corrected for junction potential (−8 mV) between the internal solution and the extracellular solution measured using a flowing 3 M KCl electrode (Neher, 1992).”
MethodPharmacological evidence for a KATP channel in renin‐secreting cells from rat kidney
Ruß, U., Rauch, U., & Quast, U. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0781s.x · Cited by 34
“All potentials given were corrected for a liquid junction potential of 10 mV (Neher, 1992).”
BackgroundAuxin augments conductance of K + inward rectifier in maize coleoptile protoplasts
Thiel, G., & Weise, R. (1999) · Planta · doi:10.1007/s004250050532 · Cited by 34
Lotshaw, D. P. (1997) · Endocrinology · doi:10.1210/endo.138.10.5463 · Cited by 36
“Membrane potentials were corrected for liquid junction potentials as described previously (23).”
MethodPei, Z., Baizabal-Aguirre, V. M., Allen, G. J., & Schroeder, J. I. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.11.6548 · Cited by 34
Heine, M., Ponimaskin, E. G., Bickmeyer, U., & Richter, D. W. (2002) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240100690 · Cited by 34
Bond, T. D., Valverde, M. A., & Higgins, C. F. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.333bq.x · Cited by 34
“Junction potentials which developed while testing the anion permeability were measured as described previously (Neher, 1992) for each experimental solution and used to correct for the reversal potential of membrane currents.”
MethodIntracellular pH Buffering Shapes Activity-Dependent Ca2+Dynamics in Dendrites of CA1 Interneurons
Tombaugh, G. C. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.80.4.1702 · Cited by 38
Electroporation of DC-3F Cells Is a Dual Process
Wegner, L. H., Frey, W., & Silve, A. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.01.038 · Cited by 33
Valente, P., Lignani, G., Medrihan, L., Bosco, F., Contestabile, A., Lippiello, P., Ferrea, E., Schachner, M., Benfenati, F., Giovedì, S., et al. (2016) · Journal of Cell Science · doi:10.1242/jcs.182089 · Cited by 37
“In all voltage-clamp experiments, the Vh was set at−70 mV (Neher, 1992; Fricker et al., 1999).”
MethodFunctional Properties of Human Stem Cell‐Derived Neurons in Health and Disease
Weick, J. P. (2016) · Stem Cells International · doi:10.1155/2016/4190438 · Cited by 37
“However, it is now known that a large family of two-pore forming KCNK channels is largely responsible for K + conductance that drives RMP [27].”
Amakhin, D. V., Soboleva, E. B., Ergina, J. L., Malkin, S. L., Chizhov, A. V., & Zaitsev, A. V. (2018) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2018.00486 · Cited by 34
“The liquid junction potential for the CsMeS04-based pipette solution was estimated as described previously (Neher, 1992), and the holding potential was compensated for offline for voltage-clamp recordings by subtracting 7 mV.”
MethodZheng, N., & Raman, I. M. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.1834-11.2011 · Cited by 33
“A 6 mV junction potential was subtracted from all data, measured by the technique of Neher (1992).”
MethodShevchenko, T. I., Teruyama, R., & Armstrong, W. E. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00431.2004 · Cited by 33
“Voltages were corrected for a liquid junction potential of 10 mV, measured empirically according to Neher (1992).”
MethodDeveloping Fast Fluorescent Protein Voltage Sensors by Optimizing FRET Interactions
Sung, U., Rad, M. S., Piao, H. H., Jin, L., Hughes, T. E., Cohen, L. B., & Baker, B. J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0141585 · Cited by 33
“We calculated [23] the liquid junction potential for the pipette solution of 120 mM K-gluconate, 3 mM KCl, 7 mM NaCl, 4 mMMg-ATP, 0.”
MethodMechanisms of somatostatin‐evoked responses in neurons of the rat lateral amygdala
Meis, S., Sosulina, L., Schulz, S., Höllt, V., & Pape, H. (2005) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2005.03922.x · Cited by 35
“Correction for a liquid junction potential of 10 mV was applied (Neher, 1992).”
MethodInfluentialMienville, J., Lange, G. D., & Barker, J. L. (1994) · Developmental Brain Research · doi:10.1016/0165-3806(94)90216-x · Cited by 34
Baufreton, J., Garret, M., Doveró, S., DUFY, B., Bioulac, B. H., & Taupignon, A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.86.1.75 · Cited by 36
Chloride channels activated by hypotonicity in N2A neuroblastoma cell line
Carpaneto, A., Accardi, A., Pisciotta, M., & Gambale, F. (1999) · Experimental Brain Research · doi:10.1007/s002210050614 · Cited by 33
Haage, D., Karlsson, U., & Johansson, S. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.077bu.x · Cited by 33
“The liquid-junction potential, measured as described by Neher (1992), has been subtracted in all potential values given.”
BackgroundKepplinger, K. J. F., Förstner, G., Kahr, H., Leitner, K., Pammer, P., Groschner, K., Soldatov, N. M., & Romanin, C. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00119.x · Cited by 33
“This value should be subtracted from all voltages in whole-cell recordings (Neher, 1992).”
BackgroundSynaptic Conductances during Interictal Discharges in Pyramidal Neurons of Rat Entorhinal Cortex
Amakhin, D. V., Ergina, J. L., Chizhov, A. V., & Zaitsev, A. V. (2016) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2016.00233 · Cited by 37
“The liquid junction potentials were measured as described (Neher, 1992), and the holding potential was compensated for offline for voltage-clamp recordings by subtracting 7mV for iS-2 and 5mV for iS-3.”
MethodWerginz, P., Raghuram, V., & Fried, S. I. (2020) · Science Advances · doi:10.1126/sciadv.abb6642 · Cited by 32
Hodin, J., Lind, C., Marmagne, A., Espagne, C., Bianchi, M. W., Angeli, A. D., Abou-Choucha, F., Bourge, M., Chardon, G., Thomine, S., et al. (2022) · The Plant Cell · doi:10.1093/plcell/koac325 · Cited by 32
Vertebrate OTOP1 is also an alkali-activated channel
Tian, L., Zhang, H., Yang, S., Luo, A., Kamau, P. M., Hu, J., Luo, L., & Lai, R. (2023) · Nature Communications · doi:10.1038/s41467-022-35754-9 · Cited by 32
Metadata
- Authors
- Neher, E.
- Affiliations
- Max Planck Society (DE)
- Corresponding author
- Neher, Erwin
- ORCID
- Neher, Erwin
- Venue
- Methods in Enzymology
- Publisher
- Elsevier
- Published
- 1992
- Volume
- 207
- Pages
- 123-131
- ISSN
- 0076-6879 (ISSN-L)
- OpenAlex
- W1561818412
- Cited by
- 1,132
- References
- 6
- Citations by year
- 2026: 14 · 2025: 17 · 2024: 11 · 2023: 13 · 2022: 19 · 2021: 19 · 2020: 35 · 2019: 26 · 2018: 25 · 2017: 21 · 2016: 24 · 2015: 29 · 2014: 25 · 2013: 31 · 2012: 28
- FWCI
- 27.85
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- Methods in enzymology on CD-ROM/Methods in enzymology (publishedVersion)
- PubMed (publishedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- liquid junction potential, patch clamp, reference electrode, Ag/AgCl electrodes, salt bridges, microperfusion
- MeSH terms
- Amplifiers, Electronic, Electrophysiology, Membrane Potentials, Microelectrodes, Potentiometry, Solutions, Artifacts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.