Automated three-dimensional finite element modelling of bone: a new method
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Three-dimensional finite element stress analysis of bone is a key to understanding bone remodelling, assessing fracture risk, and designing prostheses; however, the cost and complexity of predicting the stress field in bone with accuracy has precluded the routine use of this method. A new, automated method of generating patient-specific three-dimensional finite element models of bone is presented--it uses digital computed tomographic (CT) scan data to drive the geometry of the bone and to estimate its inhomogeneous material properties. Cubic elements of a user-specified size are automatically defined and then individually assigned the CT scan-derived material properties. The method is demonstrated by predicting the stress, stain, and strain energy in a human proximal femur in vivo. Three-dimensional loading conditions corresponding to the stance phase of gait were taken from the literature and applied to the model. Maximum principal compressive stresses of 8-23 MPa were computed for the medial femoral neck. Automated generation of additional finite element models with larger numbers of elements was used to verify convergence in strain energy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Changes in Trabecular Pattern of the Upper End of the Femur as an Index of Osteoporosis
SINGH, M., NAGRATH, A. R., & MAINI, P. S. (1970) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197052030-00005 · Cited by 1,151
Precise Measurement of Vertebral Mineral Content Using Computed Tomography
Cann, C. E., & Genant, H. K. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198008000-00018 · Cited by 540
A survey of finite element analysis in orthopedic biomechanics: The first decade
Huiskes, R., & Chao, E. Y. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90072-6 · Cited by 539
Bone Deformation Recorded in vivo from Strain Gauges Attached to the Human Tibial Shaft
Lanyon, L. E., Hampson, W. G. J., Goodship, A. E., & Shah, J. S. (1975) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677508989216 · Cited by 475
Prediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
On the mathematical analysis of stress in the human femur
Rybicki, E. F., Simonen, F. A., & Weis, E. B. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90056-5 · Cited by 286
Mechanical Property Distributions in the Cancellous Bone of the Human Proximal Femur
Brown, T. D., & Ferguson, A. B. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990819 · Cited by 282
Three dimensional stress analysis of the human femur
Valliappan, S., Svensson, N. L., & Wood, R. D. (1977) · Computers in Biology and Medicine · doi:10.1016/0010-4825(77)90031-2 · Cited by 77
Fast Contour Detection Algorithm for High Precision Quantitative CT
Seitz, P., & Ruegsegger, P. (1983) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1983.4307627 · Cited by 46
Cited by
Additive manufacturing of tissues and organs
Melchels, F. P. W., Domingos, M. A. N., Klein, T. J., Malda, J., Bartolo, P. J., & Hutmacher, D. W. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.11.007 · Cited by 1,213
Application of finite element analysis in implant dentistry: A review of the literature
Geng, J.-P., Tan, K. B. C., & Liu, G.-R. (2001) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2001.115251 · Cited by 1,106
Relations of mechanical properties to density and CT numbers in human bone
Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)97314-f · Cited by 822
Prediction of femoral fracture load using automated finite element modeling
Keyak, J. H., Rossi, S. A., Jones, K. A., & Skinner, H. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00123-1 · Cited by 682
Self-citationMathematical relationships between bone density and mechanical properties: A literature review
Helgason, B., Perilli, E., Schileo, E., Taddei, F., Brynjólfsson, S., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.024 · Cited by 589
Crawford, R. P., Cann, C. E., & Keaveny, T. M. (2003) · Bone · doi:10.1016/s8756-3282(03)00210-2 · Cited by 547
Femoral strength is better predicted by finite element models than QCT and DXA
Cody, D. D., Gross, G. J., J. Hou, F., Spencer, H. J., Goldstein, S. A., & P. Fyhrie, D. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00099-8 · Cited by 440
Taddei, F., Schileo, E., Helgason, B., Cristofolini, L., & Viceconti, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.10.014 · Cited by 339
A biomechanical perspective on bone quality
Hernandez, C. J., & Keaveny, T. M. (2006) · Bone · doi:10.1016/j.bone.2006.06.001 · Cited by 319
Improved prediction of proximal femoral fracture load using nonlinear finite element models
Keyak, J. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00045-5 · Cited by 314
Self-citationFinite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older Men
Orwoll, E. S., Marshall, L. M., Nielson, C. M., Cummings, S. R., Lapidus, J., Cauley, J. A., Ensrud, K., Lane, N., Hoffmann, P. R., Kopperdahl, D. L., et al. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081201 · Cited by 265
Keyak, J. H., & Falkinstein, Y. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00081-x · Cited by 259
Self-citationFinite element models in tissue mechanics and orthopaedic implant design
Prendergast, P. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00018-1 · Cited by 255
Keyak, J. H., & Rossi, S. A. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00152-9 · Cited by 250
Self-citationThree-dimensional finite element modelling of non-invasively assessed trabecular bone structures
Müller, R., & Rüegsegger, P. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)91884-j · Cited by 240
A comparative study on different methods of automatic mesh generation of human femurs
Viceconti, M., Bellingeri, L., Cristofolini, L., & Toni, A. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00049-0 · Cited by 217
“[11–13] proposed a new method to directly generate a mesh from a dataset of stacked images (CT scans, etc.”
MethodBiomechanical 3-D finite element modeling of the human breast using MRI data
Samani, A., Bishop, J., Yaffe, M. J., & Plewes, D. B. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.921476 · Cited by 217
Material properties assignment to finite element models of bone structures: a new method
Zannoni, C., Mantovani, R., & Viceconti, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00081-2 · Cited by 210
“Two different methods are generally reported for automatic FE model generation: in house developed voxelbased methods on one hand [14], and methods based on commercially available mesh generation routines on the other [15].”
MethodPrediction of fracture location in the proximal femur using finite element models
Keyak, J. H., Rossi, S. A., Jones, K. A., Les, C. M., & Skinner, H. B. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00094-7 · Cited by 199
“A threedimensional FE mesh was automatically created for each femur by deriving the outer contour of the bone from each image using a semi-automated edge detection algorithm and then generating linear, eight-noded, cubeshaped elements according to the derived bone geometry [12].”
BackgroundMethodSelf-citationThe Accuracy of Digital Image-Based Finite Element Models
Guldberg, R. E., Hollister, S. J., & Charras, G. T. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2798314 · Cited by 180
Convergence Behavior of High-Resolution Finite Element Models of Trabecular Bone
Niebur, G. L., Yuen, J. C., Hsia, A. C., & Keaveny, T. M. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2800865 · Cited by 165
Dried plum prevents bone loss in a male osteoporosis model via IGF-I and the RANK pathway.
Franklin, M., Bu, S. Y., Lerner, M. R., Lancaster, E. A., Bellmer, D., Marlow, D., Lightfoot, S. A., Arjmandi, B. H., Brackett, D. J., Lucas, E. A., et al. (2006) · Bone · doi:10.1016/j.bone.2006.05.024 · Cited by 120
Metadata
- Authors
- Keyak, J. H., Meagher, J. M., Skinner, H. B., & Mote, C. D.
- Venue
- Journal of Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 1990-09-01
- Volume
- 12
- Issue
- 5
- Pages
- 389-397
- ISSN
- 0141-5425 (ISSN-L)
- OpenAlex
- W2103374920
- Cited by
- 383
- References
- 11
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.