Biomaterial biocompatibility and the macrophage
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
The biocompatibility of biomaterials at implant sites is controlled by the tissue/material interaction. A major cell in the tissue reaction is the macrophage. A summary is presented on macrophage mediation of cellular and humoral regulatory pathways in inflammatory and immune responses.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Activated macrophages are thought to orchestrate the FBR by secreting a number of molecules that are involved in inflammation, degradation of the foreign object and surrounding tissue, and recruiting non-inflammatory cells which eventually lead to the formation of a fibrous capsule.12,13”
From Student award winner in the undergraduate category for the society of biomaterials 9th World Biomaterials Congress, Chengdu, China, June 1–5, 2012: The effects of substrate stiffness on the in vitro activation of macrophages and in vivo host response to poly(ethylene glycol)‐based hydrogels (2012) · cites this paper as [13]
Citations
Cites
Interleukin 1, a potential regulator of fibroblast proliferation.
Schmidt, J. A., Mizel, S. B., Cohen, D., & Green, I. (1982) · The Journal of Immunology · doi:10.4049/jimmunol.128.5.2177 · Cited by 831
Baracos, V., Rodemann, H. P., Dinarello, C. A., & Goldberg, A. L. (1983) · New England Journal of Medicine · doi:10.1056/nejm198303103081002 · Cited by 690
Craddock, P. R., Hammerschmidt, D., White, J. G., Dalmosso, A. P., & Jacob, H. S. (1977) · Journal of Clinical Investigation · doi:10.1172/jci108763 · Cited by 685
Corticosteroids inhibit murine macrophage Ia expression and interleukin 1 production.
Snyder, D. S., & Unanue, E. R. (1982) · The Journal of Immunology · doi:10.4049/jimmunol.129.5.1803 · Cited by 649
A macrophage-dependent factor that stimulates the proliferation of fibroblasts in vitro.
Leibovich, S. J., & Ross, R. (1976) · PubMed Central · Cited by 576
Sutton, J. S., & Weiss, L. (1966) · The Journal of Cell Biology · doi:10.1083/jcb.28.2.303 · Cited by 444
Interleukin 1 stimulation of collagenase production by cultured fibroblasts.
Postlethwaite, A. E., Lachman, L. B., Mainardi, C. L., & Kang, A. H. (1983) · The Journal of experimental medicine · doi:10.1084/jem.157.2.801 · Cited by 368
Rennard, S. I., Hunninghake, G. W., Bitterman, P. B., & Crystal, R. G. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.11.7147 · Cited by 340
Werb, Z., Banda, M. J., & Jones, P. A. (1980) · The Journal of experimental medicine · doi:10.1084/jem.152.5.1340 · Cited by 311
Fibronectin fragment(s) are chemotactic for human peripheral blood monocytes.
Norris, D. A., Clark, R. A. F., Swigart, L. M., Huff, J. C., Weston, W. L., & Howell, S. E. (1982) · The Journal of Immunology · doi:10.4049/jimmunol.129.4.1612 · Cited by 288
Research works printed but not linked: 4
- Atkinson, 1980, Vol. 1, 219
- Becker, 1980, Vol. 1, 272
- Allison, 1982, Vol. 1, 101
- Gordon, 1978, Vol. 2, 33.1
Cited by
Items 201–300 of 404
The tissue response to photopolymerized PEG‐p(HPMAm‐lactate)‐based hydrogels
Censi, R., van Putten, S., Vermonden, T., Martino, P. D., van Nostrum, C. F., Harmsen, M. C., Bank, R. A., & Hennink, W. E. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33048 · Cited by 28
Cellular reaction on the intraperitoneal injection of four types of polylactide particulates
van Sliedregt, A., Knook, M., Hesseling, S. C., Koerten, H. K., de Groot, K., & van Blitterswijk, C. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90174-m · Cited by 26
Gretzer, C., Eriksson, A., Alldén, B., Ericson, L. E., & Thomsen, P. (1996) · Biomaterials · doi:10.1016/0142-9612(96)83279-0 · Cited by 30
Schulte, V. A., Díez, M., Hu, Y., Möller, M., & Lensen, M. C. (2010) · Biomacromolecules · doi:10.1021/bm100881y · Cited by 26
Haemocompatiblity of controlled release glass
Cartmell, S. H., Doherty, P., Rhodes, N., Hunt, J. A., Healy, D. M., & Gilchrist, T. (1998) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008830025416 · Cited by 25
Immune response against polyester implants is influenced by the coating substances
Wilhelm, L., Zippel, R., von Woedtke, T., Kenk, H., Hoene, A., Patrzyk, M., & Schlosser, M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31209 · Cited by 25
In vivo testing of crosslinked polyethers. I. Tissue reactions and biodegradation
Pol, B. J. M., van der Does, L., Bantjes, A., van Wachem, P. B., & van Luyn, M. J. A. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199611)32:3<307::aid-jbm3>3.0.co;2-w · Cited by 27
The effect of hydrocortisone acetate loaded poly(DL-lactide) films on the inflammatory response
Spilizewski, K. L., Marchant, R. E., Hamlin, C. R., Anderson, J. M., Tice, T. R., Dappert, T. O., & Meyers, W. E. (1985) · Journal of Controlled Release · doi:10.1016/0168-3659(85)90045-8 · Cited by 27
Self-citationThèrin, M., Christel, P., & Meunier, A. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820281104 · Cited by 24
How does the pathophysiological context influence delivery of bone growth factors?
Yu, X., Suárez-González, D., Khalil, A. S., & Murphy, W. L. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.10.010 · Cited by 26
Bartnikowski, M., Moon, H., & Ivanovski, S. (2018) · Biomedical Materials · doi:10.1088/1748-605x/aad916 · Cited by 25
Erfani, A., Hanna, A., Zarrintaj, P., Manouchehri, S., Weigandt, K. M., Aichele, C. P., & Ramsey, J. D. (2021) · Soft Matter · doi:10.1039/d1sm00154j · Cited by 23
Evaluation of Cell Behaviour on Atmospheric Plasma Deposited Siloxane and Fluorosiloxane Coatings
Ardhaoui, M. E., Naciri, M., Mullen, T., Brugha, C. M., KEENAN, A. K., Al‐Rubeai, M., & Dowling, D. P. (2010) · Journal of Adhesion Science and Technology · doi:10.1163/016942409x12598231567943 · Cited by 23
Oberdiek, F., Vargas, C. I., Rider, P., Batinic, M., Görke, O., Radenković, M. B., Najman, S. J., Baena, J. M., Jung, O., & Barbeck, M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22073588 · Cited by 25
Smith, M. J., Smith, D. C., White, K. L., & Bowlin, G. L. (2007) · Journal of Engineered Fibers and Fabrics · doi:10.1177/155892500700200205 · Cited by 24
“C5a, C3b, and iC3b) can promote macrophage activation and opsonization [10, 11]; macrophages can be stimulated to release a wide variety of signals (cytokines), including interleukins (IL), interferons (IFN), and tumor necrosis factors (TNF), which in turn mediate other processes, including maintaining inflammation, p…”
BackgroundEarly inflammatory response in soft tissues induced by thin calcium phosphates
Rydén, L., Molnar, D., Esposito, M. A., Johansson, A., Suska, F., Palmquist, A., & Thomsen, P. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34571 · Cited by 23
In vivo fluorescence imaging of apoptosis during foreign body response
Bartsch, I., Willbold, E., Yarmolenko, S. N., & Witte, F. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.039 · Cited by 22
“[16,17], the distraction of an intact tissue evokes inflammation when placing a biomaterial in the in vivo environment and is followed by wound healing and a foreign body reaction as parts of the tissue response.”
BackgroundPolymeric Scaffolds for Tissue Engineering Applications
(2007) · CRC Press eBooks · doi:10.1201/9781420008333-14 · Cited by 22
In vitro cytotoxicity of dental casting alloys over 8 months
Wataha, J. C., Lockwood, P. E., Nelson, S. K., & Rakich, D. R. (1999) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.1999.00398.x · Cited by 25
Jacob‐LaBarre, J. T., Assouline, M., Byrd, T. J., & McDonald, M. B. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280607 · Cited by 25
Ni(II) ions dysregulate cytokine secretion from human monocytes
Lewis, J. B., Messer, R. L. W., Pitts, L., Hsu, S., Hansen, J. M., & Wataha, J. C. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31063 · Cited by 21
Soft tissue findings above submerged titanium implants—a histological and spectroscopic study
Schlegel, K. A., Eppeneder, S., & Wiltfang, J. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00423-9 · Cited by 21
Laquerrière, P., Grandjean-Laquerriere, A., Guenounou, M., Laurent‐Maquin, D., Frayssinet, P., & Nardin, M. (2003) · Colloids and Surfaces B Biointerfaces · doi:10.1016/s0927-7765(03)00083-3 · Cited by 21
Creep of a poly(etherurethane urea) in an oxidative environment
Wu, Y.-T., Lodoen, G. A., Anderson, J. M., Baer, E., & Hiltner, A. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280414 · Cited by 21
Self-citationRedox responsive albumin autogenic nanoparticles for the delivery of cancer drugs
Raja, S. T. K., Prakash, T., & Gnanamani, A. (2017) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2017.01.044 · Cited by 20
Saad, B., Ciardelli, G., Matter, S., Welti, M., Uhlschmid, G. K., Neuenschwander, P., & Suter, U. W. (1996) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00121191 · Cited by 20
Titanates deliver metal ions to human monocytes
Wataha, J. C., Hobbs, D. T., Wong, J. J., Dogan, S., Zhang, H. F., Chung, K.-H., & Elvington, M. C. (2009) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-009-3941-8 · Cited by 19
“mation, and biological response to materials [5, 6].”
BackgroundMethodHsieh, C. Y. C., Hu, F.-W., Chen, W., & Tsai, W. (2014) · ISRN Biomaterials · doi:10.1155/2014/718432 · Cited by 22
“Thus, it is suggested that reduction of macrophage adhesion and activation may reduce the formation of the foreign body reaction and capsule formation [1, 7, 8].”
Backgroundde Souza, G. L., de Rosatto, C. M. P., Silva, M. J. B., da Silva, M. V., Rodrigues, D. B. R., & Moura, C. C. G. (2018) · International Endodontic Journal · doi:10.1111/iej.13036 · Cited by 19
“After colonization of the wound site by neutrophils, monocyte migration occurs (Anderson & Miller 1984).”
BackgroundMechanisms Underlying Anti-Inflammatory and Anti-Cancer Properties of Stretching—A Review
Król, M., Kupnicka, P., Bosiacki, M., & Chlubek, D. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms231710127 · Cited by 23
Laquerrière, P., Grandjean-Laquerriere, A., Kilian, L., Beorchia, A., Guenounou, M., Jallot, É., Balossier, G., & Frayssinet, P. (2003) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2003.08.012 · Cited by 22
Dolatshahi‐Pirouz, A., Jensen, T., Vorup‐Jensen, T., Bech, R., Chevallier, J., Besenbacher, F., Foss, M., & Sutherland, D. S. (2010) · Advanced Engineering Materials · doi:10.1002/adem.201000120 · Cited by 19
Zhu, X., Yuan, Z., Yan, P., Li, Y., Jiang, H., & Huang, S. (2017) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2017.03.010 · Cited by 22
Cytotoxic reaction and TNF-α response of macrophages to polyurethane particles
Nan, N., Petit, A., Yahia, L., Huk, O. L., & Tabrizian, M. (2002) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856202320176510 · Cited by 21
Rosengren, A., Bjursten, L. M., & Danielsen, N. (1998) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1013239731256 · Cited by 19
Environmental Stress Cracking in Implanted Polyurethane Devices
Stokes, K., & Davis, M. W. (1987) · Springer eBooks · doi:10.1007/978-1-4613-1829-3_16 · Cited by 18
Review of Medical Biosensors and Associated Materials Problems
Regnault, W. F., & Picciolo, G. L. (1987) · Journal of Biomedical Materials Research · doi:10.1002/j.1097-4636.1987.tb00016.x · Cited by 18
Chen, Y., Yang, T., Wang, S., Tong, D., Liu, X., Li, Y., Zhao, W., & Zhao, C. (2025) · Journal of Materials Chemistry B · doi:10.1039/d4tb01952k · Cited by 17
Circulating blood monocytes traffic to and participate in the periprosthetic tissue inflammation
Zhang, K., Jia, T., McQueen, D. A., Gong, W., Markel, D. C., Wooley, P. H., & Yang, S. (2009) · Inflammation Research · doi:10.1007/s00011-009-0051-5 · Cited by 17
“during the aseptic loosening process [9, 10], the molecular mechanisms of the circulating monocytes homing to the prosthetic joint and forming the periprosthetic tissue have yet to be fully understood.”
Bangash, A., Khan, N., Sadiq, M., Hadi, A. U., & Hamid, H. (2010) · Saudi Journal of Gastroenterology · doi:10.4103/1319-3767.58761 · Cited by 17
“The amount of fibrosis and inflammatory reaction varies with the physiochemical properties of the mesh, the surface area and the type of protein absorbed.[18,19]”
BackgroundYang, J., Cao, X., Zhao, Y., Wang, L., Liu, B., Jia, J., Liang, H., & Chen, M. (2017) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2017.1279534 · Cited by 17
“However, its practical applications have been restricted by the following several drawbacks [5-18].”
BackgroundInfluentialHanson, S. R., Lalor, P., Niemi, S. M., NORTHUP, S. J., Ratner, B. D., Spector, M., Vale, B. H., & Willson, J. E. (1996) · Elsevier eBooks · doi:10.1016/b978-0-08-050014-0.50010-9 · Cited by 17
Metal Catalyzed Oxidative Degradation of Implanted Polyurethane Devices
Stokes, K., Berthelson, W. A., & Davis, M. W. (1987) · Springer eBooks · doi:10.1007/978-1-4613-1829-3_17 · Cited by 17
Biofunctionality and Biocompatibility
Williams, D. F. (2006) · Materials Science and Technology · doi:10.1002/9783527603978.mst0160 · Cited by 17
Diamond-like carbon (DLC) as a biocompatible coating in orthopaedic and cardiac medicine
Ma, W., Ruys, A. J., & Zreiqat, H. (2009) · Elsevier eBooks · doi:10.1533/9781845695477.2.391 · Cited by 18
Low dose metal particles can induce monocyte/macrophage survival
Lacey, D. C., de Kok, B., Clanchy, F. I. L., Bailey, M. J., Speed, K., Haynes, D. R., Graves, S. E., & Hamilton, J. A. (2009) · Journal of Orthopaedic Research® · doi:10.1002/jor.20914 · Cited by 16
Sadtler, K., & Elisseeff, J. H. (2019) · Biomaterials Science · doi:10.1039/c9bm00349e · Cited by 17
Inflammatory Response to a Titanium Surface with Potential Bioactive Properties: An In Vitro Study
Göransson, A., Gretzer, C., Johansson, A., Sul, Y., & Wennerberg, A. (2006) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2006.00021.x · Cited by 16
Fulzele, S. V., Satturwar, P. M., & Dorle, A. K. (2006) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20730 · Cited by 16
Chemotaxis and the inhibition of chemotaxis of human neutrophils in reponse to metal ions
Remes, A., & Williams, D. F. (1990) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00705350 · Cited by 16
The role of Toll-like receptor signaling in the macrophage response to implanted materials
McKiel, L. A., Woodhouse, K. A., & Fitzpatrick, L. E. (2020) · MRS Communications · doi:10.1557/mrc.2019.154 · Cited by 18
Kochanowski, A., Hoene, A., Patrzyk, M., Walschus, U., Finke, B., Luthringer-Feyerabend, B., Feyerabend, F., Willumeit‐Römer, R., Lucke, S., & Schlosser, M. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4287-6 · Cited by 15
“their ability to phagocytize a foreign material and to subsequently cause attraction of neutrophils, monocytes, Tand B-lymphocytes by secretion of cytokines [28, 35].”
BackgroundNatural and Synthetic Polymeric Scaffolds
Yoon, D. M., & Fisher, J. P. (2020) · Springer eBooks · doi:10.1007/978-3-030-49206-9_6 · Cited by 21
Dysregulation of monocytic cytokine secretion by endodontic sealers
Brackett, M. G., Lewis, J. B., Messer, R. L. W., Lei, L., Lockwood, P. E., & Wataha, J. C. (2011) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31785 · Cited by 18
Ung, D. Y., Woodhouse, K. A., & Sefton, M. V. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19990905)46:3<324::aid-jbm3>3.0.co;2-5 · Cited by 15
Giridhar, G., Gristina, A. G., & Myrvik, Q. N. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90180-a · Cited by 16
Development of In Vitro Biocompatibility Assays for Surgical Material
Charissoux, J.-L., Najid, A., Cook‐Moreau, J., Setton, D., & Rigaud, M. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199605000-00033 · Cited by 15
Désévaux, C., Girard, C. A., Lenaerts, V., & Dubreuil, P. (2002) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(01)00912-7 · Cited by 15
Lignin nanoparticle–based nanocomposite hydrogels for biomedical applications
Ribeiro, A. M., Santos, A. I., Veiga, F., & Figueiras, A. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-99638-9.00003-4 · Cited by 15
Rouxhet, L., Legras, R., & Schneider, Y. (1998) · Macromolecular Symposia · doi:10.1002/masy.19981300130 · Cited by 14
Divakar, P., Moodie, K. L., Demidenko, E., Hoopes, P. J., & Wegst, U. G. K. (2019) · Biomedical Materials · doi:10.1088/1748-605x/ab316a · Cited by 14
Polymeric Scaffolds for Tissue Engineering Applications
Yoon, D. M., & Fisher, J. P. (2007) · CRC Press eBooks · doi:10.1201/9781420008333.sec2 · Cited by 24
Biocompatibility evaluation of laser-induced AAm and HEMA grafted EPR. Part 1: In-vitro study
Mirzadeh, H., Khorasani, M. T., Katbab, A. A., Burford, R. P., Soheili, Z., Golestani, A., & Goliaei, B. (1994) · Clinical Materials · doi:10.1016/0267-6605(94)90115-5 · Cited by 15
Lee, D., Park, J., & Suh, H. (2001) · Journal of Biomedical Materials Research · Cited by 14
Morphometric Evaluation of Tissue-Implant Reaction Associated With ALCAP and TCP Bioceramics In Vivo
Butler, K. R., Benghuzzi, H., & Puckett, A. D. (2001) · Journal of Investigative Surgery · doi:10.1080/089419301300343291 · Cited by 14
Biological Properties of Chitosan/Collagen Composites
Sionkowska, A., Kaczmarek, B., Stalińska, J., & Osyczka, A. M. (2013) · Key engineering materials · doi:10.4028/www.scientific.net/kem.587.205 · Cited by 13
“Due to their application, they have to be biocompatible, biodegradable and non-toxic for living organism [8-10].”
BackgroundMicrodialysis sampling techniques applied to studies of the foreign body reaction
Sides, C. R., & Stenken, J. A. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2013.11.002 · Cited by 20
“…Cells While the functions of different cell types involved in the various stages of the FBR have been investigated, the macrophage is a predominant cell that has attracted the most attention due to its role in significantly directing the FBR (Anderson and Miller, 1984; Anderson et al., 2008).”
BackgroundNanomaterials based flexible devices for monitoring and treatment of cardiovascular diseases (CVDs)
Xiang, Z., Han, M., & Zhang, H. (2022) · Nano Research · doi:10.1007/s12274-022-4551-8 · Cited by 13
Furcellaran Surface Deposition and Its Potential in Biomedical Applications
Štěpánková, K., Özaltın, K., Pelková, J., Pištěková, H., Karakurt, I., Káčerová, S., Lehocký, M., Humpolíček, P., Vesel, A., & Mozetič, M. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23137439 · Cited by 14
“The current problem that can be encountered with biomaterials used for implants and other devices may be acute and chronic inflammatory responses, ultimately leading to fibrous capsule formation and thereby impairing normal tissue growth [19,20].”
BackgroundGretzer, C., Thomsen, P., Jansson, S. K. G., & Nilsson, M. (2000) · Cytokine · doi:10.1006/cyto.1999.0523 · Cited by 13
Bryan, N., Battersby, C. L. F., Smart, N. J., & Hunt, J. A. (2014) · Hernia · doi:10.1007/s10029-014-1307-8 · Cited by 13
“Over the proceeding days, neutrophils are accompanied by macrophages and famed debridement through phagocytosis, and these cells also signal and are arguably the most rate limiting cell throughout tissue healing [5].”
BackgroundAntigenicity of Polyester (Dacron) Vascular Prostheses in an Animal Model
Zippel, R., Wilhelm, L., Marusch, F., Koch, A., Urban, G., & Schlosser, M. (2001) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.2000.1298 · Cited by 13
Effects of bioactive glass particles and their ionic products on intracellular concentrations
Laquerrière, P., Jallot, É., Kilian, L., Benhayoune, H., & Balossier, G. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10498 · Cited by 13
A Review of Complications and Their Treatments in Facial Aesthetic Surgery
Guthrie, A., Kadakia, S., Cranford, J., Sawhney, R., & Ducic, Y. (2017) · The American Journal of Cosmetic Surgery · doi:10.1177/0748806816689619 · Cited by 12
“This capsule serves as a barrier between the host (the patient) and the implant.(22,23) Complications of facial implants commonly occur as a result of a chronic, unresolved inflammatory response to the implant material.”
BackgroundPseudointima in inflow conduits of left ventricular assist devices
Hoüel, R., MOCZAR, M., Clerin, V. M., & Loisance, D. Y. (1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(99)00527-5 · Cited by 12
Quantification of the inflammatory response in exudates to three polymers implantedin vivo
Fabre, T., Bertrand-Barat, J., Freyburger, G., Rivel, J., Dupuy, B., Durandeau, A., & Baquey, C. (1998) · Journal of Biomedical Materials Research · Cited by 12
Cytotoxicity of endodontic sealers after one year of aging in vitro
Brackett, M. G., Lewis, J. B., Kious, A. R., Messer, R. L. W., Lockwood, P. E., Brackett, W. W., & Wataha, J. C. (2012) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.32739 · Cited by 16
Macrophage retrieval from 3D biomaterials: A detailed comparison of common dissociation methods
Feuerer, N., Morschl, J., Daum, R., Weiß, M., Hinderer, S., Schenke‐Layland, K., & Shipp, C. (2020) · Journal of Immunology and Regenerative Medicine · doi:10.1016/j.regen.2020.100035 · Cited by 16
Sustained Release of Antibacterial Lipopeptides from Biodegradable Polymers against Oral Pathogens
Eckhard, L. H., Houri‐Haddad, Y., Sol, A., Zeharia, R., Shai, Y., Beyth, S., Domb, A. J., Bachrach, G., & Beyth, N. (2016) · PLoS ONE · doi:10.1371/journal.pone.0162537 · Cited by 11
Macrophage responses to a Zr-based bulk metallic glass.
Huang, L., Tao, Z., Liaw, P., & He, W. (2013) · Journal of Biomedical Materials Research. Part A · doi:10.1002/jbm.a.35009 · Cited by 13
Continuous Intra-arterial Blood Gas Monitoring
Venkatesh, B. (1999) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)00124-2 · Cited by 11
Degradation and intrahepatic compatibility of albumin-heparin conjugate microspheres
Cremers, H. F. M., Wotf, R. F. E., BLAAUW, E. H., Schakenraad, J. M., Lam, K. H., Nieuwenhuis, P., Verrijk, R., Kwon, G. S., Bae, Y. H., Kim, S., et al. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90207-0 · Cited by 11
Adhesion Behavior of Peritoneal Cells on the Surface of Self-Assembled Triblock Copolymer Hydrogels
Tanaka, S., Ogura, A., Kaneko, T., Murata, Y., & Akashi, M. (2004) · Biomacromolecules · doi:10.1021/bm049653o · Cited by 12
Biocompatibility of poly(etherurethane urea) containing dehydroepiandrosterone
Collier, T. O., Tan, J., Shive, M. S., Hasan, S. M., Hiltner, A., & Anderson, J. (1998) · Journal of Biomedical Materials Research · Cited by 11
Self-citationImplant-Related Biological Reactions
Oshida, Y. (2007) · Elsevier eBooks · doi:10.1016/b978-008045142-8/50007-4 · Cited by 12
von Mentzer, U., Corciulo, C., & Stubelius, A. (2022) · Macromolecular Bioscience · doi:10.1002/mabi.202200037 · Cited by 11
Nocca, G., Sole, P. D., Gambarini, G., Palma, F. D., Parziale, V., Giardina, B., & Lupi, A. (2006) · Luminescence · doi:10.1002/bio.909 · Cited by 10
Influence des propriétés physicochimiques d'hydroxyapatites sur le comportement cellulaire
Laquerrière, P., Grandjean-Laquerriere, A., Jallot, É., Nardin, M., Frayssinet, P., Nédélec, J., & Laurent‐Maquin, D. (2005) · ITBM-RBM · doi:10.1016/j.rbmret.2005.04.007 · Cited by 10
“l’inflammation comme les cytokines et les métaloprotéinases qui peuvent ensuite interagir avec d’autres types cellulaires tel que les ostéoclastes [6].”
BackgroundSubcutaneous tissue reaction to synthetic auditory ossicle (Apaceram®) in rats
Cui, P., Ohsaki, K., Ii, K., Tenshin, S., & Kawata, T. (1995) · The Journal of Laryngology & Otology · doi:10.1017/s0022215100129135 · Cited by 10
“The biological response to an implant can be attributed to acute and chronic inflammatory changes, following the formation of a fibrous capsule, which occur over a period of time (Anderson and Miller, 1984).”
BackgroundIn vitro testing of dental materials by means of macrophage cultures I: Methodological aspects
Syrjänen, S., Nilner, K., & Hensten‐Pettersen, A. (1986) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820200805 · Cited by 10
Suvannapruk, W., Fisher, L. E., Luckett, J., Edney, M. K., Kotowska, A. M., Kim, D., Scurr, D. J., Ghaemmaghami, A. M., & Alexander, M. R. (2024) · Advanced Science · doi:10.1002/advs.202306000 · Cited by 9
Pintwala, R., Postnikoff, C., Molladavoodi, S., & Gorbet, M. (2014) · Journal of Biomaterials Applications · doi:10.1177/0885328214552711 · Cited by 9
In vitro effects of dental monomer exposure - Dependence on the cell culture model
Morisbak, E., Uvsløkk, S., & Samuelsen, J. T. (2020) · Toxicology in Vitro · doi:10.1016/j.tiv.2020.104906 · Cited by 9
Testarelli, L., Nocca, G., Lupi, A., Pacifici, L., Pompa, G., Vozza, I., & Gambarini, G. (2012) · European Journal of Inflammation · doi:10.1177/1721727x1201000112 · Cited by 9
Portela, A., Vasconcelos, M., Branco, R., Gärtner, F., Faria, M., & Cavalheiro, J. (2010) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-010-4093-6 · Cited by 12
Biocompatibility of Elastomers
Chauvel‐Lebret, D., Auroy, P., & Bonnaure‐Mallet, M. (2013) · CRC Press eBooks · doi:10.1201/b13757-15 · Cited by 10
Li, D.-J., Ohsaki, K., Ii, K., Ye, Q., Nobuto, Y., Tenshin, S., & Takano‐Yamamoto, T. (1997) · The Journal of Laryngology & Otology · doi:10.1017/s0022215100138411 · Cited by 9
Hg2+ and Ni2+ alter induction of heat shock protein‐72 in THP‐1 human monocytes
Noda, M., Wataha, J. C., Lewis, J. B., Lockwood, P. E., Komatsu, H., & Sano, H. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10100 · Cited by 9
Gretzer, C., Johansson, A., Björkman, U., Ericson, L. E., & Thomsen, P. (2002) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1016154504574 · Cited by 10
Xiang, Z., & Spector, M. (2005) · Wiley eBooks · doi:10.1002/0471732877.emd012 · Cited by 8
Metadata
- Authors
- Anderson, J. M., & Miller, K. M.
- Affiliations
- Case Western Reserve University (US)
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1984-01
- Volume
- 5
- Issue
- 1
- Pages
- 5-10
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2049941759
- Semantic Scholar
- 315a4df6e436ef2eccfd8976e1bc9ed267343deb
- Cited by
- 403
- References
- 48
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 6 · 2023: 6 · 2022: 8 · 2021: 10 · 2020: 11 · 2019: 10 · 2018: 7 · 2017: 10 · 2016: 12 · 2015: 8 · 2014: 10 · 2013: 14 · 2012: 15
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (HL-25239, HL-27277, HL-00779)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Life Sciences › Immunology and Microbiology › Immunology › Immune cells in cancer
- Keywords
- biomaterial biocompatibility, macrophages, implantation, inflammation, immune response, humoral regulation, cell regulation
- MeSH terms
- Biocompatible Materials, Chemotaxis, Humans, Inflammation, Macrophage Activation, Macrophages, Oxygen Consumption, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.