ISFET based enzyme sensors
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of pH: Theory and Practice
Bates, R. G., & Vijh, A. K. (1973) · Journal of The Electrochemical Society · doi:10.1149/1.2403829 · Cited by 1,389 · cited 1×
“THE GLASS ELECTRODE pH-Glass electrodes (Bates, 1973) are based on the properties of a glass membrane which is contacted on both sides by an electrolyte solution.”
BackgroundBousse, L., De Rooij, N. F., & Bergveld, P. (1983) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1983.21284 · Cited by 574 · cited 1×
“The operational mechanism of the ISFET originates from the pH sensitivity of the inorganic gate oxide, such as SiOZ, A1203, Si3N4 or Ta,O+ This mechanism is purely a surface phenomenon which can be explained by the site dissociation model (Bousse et al., 1983).”
BackgroundSelf-citationField effect transistor sensitive to penicillin
Caras, S., & Janata, J. (1980) · Analytical Chemistry · doi:10.1021/ac50062a035 · Cited by 514 · cited 2×
“As a consequence of this pH dependent activity, the dynamic range of enzyme electrodes is limited, as was already described by Caras & Janata (1980) in their first ENFET paper.”
BackgroundThe operation of an ISFET as an electronic device
Bergveld, P. (1981) · Sensors and Actuators · doi:10.1016/0250-6874(81)80004-2 · Cited by 179 · cited 1×
“The so-called threshold voltage of the transistor is, however, a function of the pH of the analyte which contains a reference electrode contacted to the common of the specially developed ISFET amplifier (Bergveld, 1981).”
BackgroundSelf-citationDiabetes mellitus: biosensors for research and management
Turner, A. P. F., & Pickup, J. C. (1985) · Biosensors · doi:10.1016/0265-928x(85)85006-9 · Cited by 120 · cited 1×
“Also, for in-vitro applications, these sensors have serious competition from amperometrically operating devices (Turner & Pickup, 1985).”
BackgroundpH-based enzyme potentiometric sensors. Part 2. Glucose-sensitive field effect transistor
Caras, S. D., Petelenz, D., & Janata, J. (1985) · Analytical Chemistry · doi:10.1021/ac00286a028 · Cited by 119
Chemically Sensitive Field Effect Transistors
Janata, J., & Huber, R. J. (1980) · Springer eBooks · doi:10.1007/978-1-4684-3776-8_3 · Cited by 115
An ISFET-based microlitre titrator: integration of a chemical sensor—actuator system
van der Schoot, B., & Bergveld, P. (1985) · Sensors and Actuators · doi:10.1016/0250-6874(85)80020-2 · Cited by 95 · cited 1×
“Previously, the present authors have shown the practical value of such a system for rapid acid-base titrations (Van der Schoot & Bergveld, 1985) and in a new type of carbon dioxide sensor with an excellent long-term stability (Van der Schoot & Bergveld, 1986).”
BackgroundSelf-citationA microsensor for urea based on an ion-selective field effect transistor
Karbue, I., Tamiya, E., Dicks, J. M., & Gotoh, M. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80046-0 · Cited by 74
pH-based enzyme potentiometric sensors. Part 3. Penicillin-sensitive field effect transistor
Caras, S. D., & Janata, J. (1985) · Analytical Chemistry · doi:10.1021/ac00286a029 · Cited by 73
Cited by
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Self-citationDiverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Detection principles of biological and chemical FET sensors
Kaisti, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.010 · Cited by 577
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Very High Density Sensing Arrays
LaFratta, C. N., & Walt, D. R. (2008) · Chemical Reviews · doi:10.1021/cr0681142 · Cited by 205
Transducer Technologies for Biosensors and Their Wearable Applications
Polat, E. O., Cetin, M. M., Tabak, A. F., Bilget Güven, E., Uysal, B. Ö., Arsan, T., Kabbani, A., Hamed, H., & Gül, S. B. (2022) · Biosensors · doi:10.3390/bios12060385 · Cited by 200
Biosensors Based on Mechanical and Electrical Detection Techniques
Chalklen, T., Jing, Q., & Kar-Narayan, S. (2020) · Sensors · doi:10.3390/s20195605 · Cited by 133
Metadata
- Authors
- van der Schoot, B. H., & Bergveld, P.
- Venue
- Biosensors
- Publisher
- Elsevier BV
- Published
- 1987-01
- Volume
- 3
- Issue
- 3
- Pages
- 161-186
- ISSN
- 0265-928X (ISSN-L)
- OpenAlex
- W2167038741
- Cited by
- 177
- References
- 16
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.