Multi-dimensional treatment planning: II. Beam's eye-view, back projection, and projection through CT sections
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conversion of complex contour line definitions into polygonal element mosaics
Christiansen, H. N., & Sederberg, T. W. (1978) · Proceedings of the 5th annual conference on Computer graphics and interactive techniques · doi:10.1145/800248.807388 · Cited by 317
Conversion of complex contour line definitions into polygonal element mosaics
Christiansen, H. N., & Sederberg, T. W. (1978) · ACM SIGGRAPH Computer Graphics · doi:10.1145/965139.807388 · Cited by 231
Cited by
Intensity-modulated radiotherapy: current status and issues of interest
(2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01749-7 · Cited by 767
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“5d) (Goitein et al., 1983).”
Proton therapy – Present and future
Mohan, R., & Grosshans, D. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.11.006 · Cited by 608
Proton radiation therapy for chordomas and chondrosarcomas of the skull base
Hug, E. B., Loredo, L. N., Slater, J. D., Devries, A., Grove, R. I., Schaefer, R. A., Rosenberg, A. E., & Slater, J. M. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.91.3.0432 · Cited by 510
Image guidance for precise conformal radiotherapy
Mackie, T. R., Kapatoes, J., Ruchala, K., Lu, W., Wu, C., Olivera, G., Forrest, L., Tome, W., Welsh, J., Jeraj, R., et al. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00090-7 · Cited by 484
St. Clair, W. H., Adams, J. A., Bues, M., Fullerton, B. C., La Shell, S., Kooy, H. M., Loeffler, J. S., & Tarbell, N. J. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)01574-8 · Cited by 363
Mutic, S., Palta, J. R., Butker, E. K., Das, I. J., Huq, M. S., Loo, L.-N. D., Salter, B. J., McCollough, C. H., & Van Dyk, J. (2003) · Medical Physics · doi:10.1118/1.1609271 · Cited by 344
Austin-Seymour, M., Munzenrider, J., Goitein, M., Verhey, L., Urie, M., Gentry, R., Birnbaum, S., Ruotolo, D., McManus, P., Skates, S., et al. (1989) · Journal of Neurosurgery · doi:10.3171/jns.1989.70.1.0013 · Cited by 306
Self-citationPhase II Study of High-Dose Photon/Proton Radiotherapy in the Management of Spine Sarcomas
DeLaney, T. F., Liebsch, N. J., Pedlow, F. X., Adams, J., Dean, S., Yeap, B. Y., McManus, P., Rosenberg, A. E., Nielsen, G. P., Harmon, D. C., et al. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.08.058 · Cited by 264
Fitzek, M. M., Thornton, A. F., Rabinov, J. D., Lev, M. H., Pardo, F. S., Munzenrider, J. E., Okunieff, P., Bussière, M., Braun, I., Hochberg, F. H., et al. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.91.2.0251 · Cited by 256
A review of proton therapy – Current status and future directions
Mohan, R. (2022) · Precision Radiation Oncology · doi:10.1002/pro6.1149 · Cited by 248
“in the early 1980s to develop a three-dimensional (3D) conformal radiotherapy planning for protons is most notable.[21,22] In the following two decades, the state-of-the-art of proton therapy planning remained relatively static.”
BackgroundDeLaney, T. F., Liebsch, N. J., Pedlow, F. X., Adams, J., Weyman, E. A., Yeap, B. Y., Depauw, N., Nielsen, G. P., Harmon, D. C., Yoon, S. S., et al. (2014) · Journal of Surgical Oncology · doi:10.1002/jso.23617 · Cited by 246
Brainstem tolerance to conformal radiotherapy of skull base tumors
Debus, J., Hug, E. B., Liebsch, N. J., O'Farrel, D., Finkelstein, D., Efird, J., & Munzenrider, J. E. (1997) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(97)00364-7 · Cited by 208
Pai, H. H., Thornton, A., Katznelson, L., Finkelstein, D. M., Adams, J. A., Fullerton, B. C., Loeffler, J. S., Leibsch, N. J., Klibanski, A., & Munzenrider, J. E. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)01387-0 · Cited by 196
Computation of digitally reconstructed radiographs for use in radiotherapy treatment design
Sherouse, G. W., Novins, K., & Chaney, E. L. (1990) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(90)90074-t · Cited by 193
Malignant astrocytomas: focal tumor recurrence after focal external beam radiation therapy
Liang, B. C., Thornton, A. F., Sandler, H. M., & Greenberg, H. S. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.75.4.0559 · Cited by 192
Compensating for heterogeneities in proton radiation therapy
Urie, M., Goitein, M., & Wagner, M. (1984) · Physics in Medicine and Biology · doi:10.1088/0031-9155/29/5/008 · Cited by 183
Self-citation3-D/2-D registration of CT and MR to X-ray images
Tomazevic, D., Likar, B., Slivnik, T., & Pernus, F. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819277 · Cited by 167
“Simulated X-ray projection images [17], called digitally reconstructed radiographs (DRRs), are produced from a CT image and the unknown pose of the CT volume relative to the X-ray image set is estimated by optimizing the similarity measure calculated from the DRR and X-ray image [8], [18].”
MethodConformal static field therapy for low volume low grade prostate cancer with rigid immobilization
Soffen, E. M., Hanks, G. E., Hwang, C. C., & Chu, J. C. H. (1991) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(91)90150-3 · Cited by 160
Wenkel, E., Thornton, A. F., Finkelstein, D., Adams, J., Lyons, S., De La Monte, S., Ojeman, R. G., & Munzenrider, J. E. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)01411-5 · Cited by 159
Single shot 2D3D image regisraton
Xie, Y., Meng, C., Guan, S., & Wang, Q. (2017) · 2017 10th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI) · doi:10.1109/cisp-bmei.2017.8302202 · Cited by 2
Metadata
- Authors
- Goitein, M., Abrams, M., Rowell, D., Pollari, H., & Wiles, J.
- Venue
- International Journal of Radiation Oncology*Biology*Physics
- Publisher
- Elsevier BV
- Published
- 1983-06
- Volume
- 9
- Issue
- 6
- Pages
- 789-797
- ISSN
- 0360-3016 (ISSN-L)
- OpenAlex
- W2116871808
- Cited by
- 392
- References
- 2
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.