First-pass nuclear magnetic resonance imaging studies using gadolinium-DTPA in patients with coronary artery disease
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Nuclear magnetic resonance (NMR) imaging has been shown to accurately portray cardiac anatomy and function. To investigate the potential of NMR imaging for the assessment of coronary stenosis in patients with chest pain, ultrafast NMR imaging in conjunction with a T1 (longitudinal relaxation time) contrast agent was performed in 17 patients with chest pain who had undergone cardiac catheterization. These included 12 patients with significant coronary artery stenoses and 4 who underwent repeat NMR study after myocardial revascularization. Cardiac images at rest were obtained during rapid intravenous injection of gadolinium-DTPA (0.04 mM/kg). Electrocardiographic-gated images were acquired over 380 ms, with repetitive images obtained every 3 to 4 s. After contrast injection, there was pronounced signal enhancement in the right ventricular cavity, followed by enhancement in the left ventricular cavity and myocardium. Regional myocardium perfused by a diseased vessel demonstrated a lower peak signal intensity (p = 0.001) and lower rate of signal increase (p = 0.001) than did myocardium perfused by coronary arteries without stenosis. Repeat NMR study after revascularization showed an increase in peak signal intensity (p less than 0.002). These results demonstrate the clinical potential of dynamic gadolinium-DTPA-enhanced NMR imaging for the assessment of coronary artery disease in patients with chest pain. In combination with anatomic and functional NMR imaging, this technique has the potential to provide a comprehensive noninvasive cardiac evaluation of patients with suspected coronary artery disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent
Weinmann, H., Brasch, R., Press, W., & Wesbey, G. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.142.3.619 · Cited by 1,231
First-pass cardiac perfusion: evaluation with ultrafast MR imaging.
Atkinson, D. J., Burstein, D., & Edelman, R. R. (1990) · Radiology · doi:10.1148/radiology.174.3.2305058 · Cited by 359
Self-citationKrivokapich, J., Smith, G. T., Huang, S. C., Hoffman, E. J., Ratib, O., Phelps, M. E., & Schelbert, H. R. (1989) · Circulation · doi:10.1161/01.cir.80.5.1328 · Cited by 280
Perfusion imaging by nuclear magnetic resonance.
Rosen, B. R., Belliveau, J. W., & Chien, D. (1989) · PubMed · Cited by 273
Estimation of human myocardial mass with MR imaging.
Katz, J., Milliken, M. C., Stray-Gundersen, J., Buja, L. M., Parkey, R. W., Mitchell, J. H., & Peshock, R. M. (1988) · Radiology · doi:10.1148/radiology.169.2.2971985 · Cited by 259
Shapiro, E. P., Rogers, W. J., Beyar, R., Soulen, R. L., Zerhouni, E. A., Lima, J. A., & Weiss, J. L. (1989) · Circulation · doi:10.1161/01.cir.79.3.706 · Cited by 163
Nissen, S. E., Elion, J. L., Booth, D. C., Evans, J. M., & DeMaria, A. N. (1986) · Circulation · doi:10.1161/01.cir.73.3.562 · Cited by 117
Left ventricular mass as determined by magnetic resonance imaging in male endurance athletes
Milliken, M. C., Stray-Gundersen, J., Peshock, R. M., Katz, J., & Mitchell, J. H. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)90228-7 · Cited by 106
Smith, F. W. (1989) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(89)90336-6 · Cited by 101
0.3‐second flash mri of the human heart
Frahm, J., Merboldt, K. D., Bruhn, H., Gyngell, M. L., Hänicke, W., & Chien, D. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130114 · Cited by 93
Current status of MR imaging contrast agents: special report.
Wolf, G. L. (1989) · Radiology · doi:10.1148/radiology.172.3.2672095 · Cited by 35
Cited by
Wu, K. C., Zerhouni, E. A., Judd, R. M., Lugo-Olivieri, C. H., Barouch, L. A., Schulman, S. P., Blumenthal, R. S., & Lima, J. A. C. (1998) · Circulation · doi:10.1161/01.cir.97.8.765 · Cited by 1,357
Edelman, R. R., & Warach, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303183281109 · Cited by 1,206
Self-citationSchwitter, J., Nanz, D., Kneifel, S., Bertschinger, K., Büchi, M., Knüsel, P. R., Marincek, B., Lüscher, T. F., & von Schulthess, G. K. (2001) · Circulation · doi:10.1161/01.cir.103.18.2230 · Cited by 663
Al-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000) · Circulation · doi:10.1161/01.cir.101.12.1379 · Cited by 578
A Preliminary Report Comparing Magnetic Resonance Coronary Angiography with Conventional Angiography
Manning, W. J., Li, W., & Edelman, R. R. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303253281202 · Cited by 544
Self-citation
Metadata
- Authors
- Manning, W. J., Atkinson, D. J., Grossman, W., Paulin, S., & Edelman, R. R.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1991-10
- Volume
- 18
- Issue
- 4
- Pages
- 959-965
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2021579596
- Cited by
- 305
- References
- 11
- FWCI
- 12.49
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.