A dynamic finite element surface model for segmentation and tracking in multidimensional medical images with application to cardiac 4D image analysis
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Differential geometry of curves and surfaces
(2011) · Choice Reviews Online · doi:10.5860/choice.48-3330 · Cited by 3,706
On active contour models and balloons
Cohen, L. D. (1991) · CVGIP: Image Understanding · doi:10.1016/1049-9660(91)90028-n · Cited by 2,153
Drebin, R. A., Carpenter, L., & Hanrahan, P. (1988) · ACM SIGGRAPH Computer Graphics · doi:10.1145/378456.378484 · Cited by 1,612
Dynamic 3D models with local and global deformations: deformable superquadrics
Terzopoulos, D., & Metaxas, D. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.85659 · Cited by 781
Self-citationConstraints on deformable models:Recovering 3D shape and nonrigid motion
Terzopoulos, D., Witkin, A., & Kass, M. (1988) · Artificial Intelligence · doi:10.1016/0004-3702(88)90080-x · Cited by 774
Self-citationRegularization of Inverse Visual Problems Involving Discontinuities
Terzopoulos, D. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767807 · Cited by 767
Self-citationSternberg, S. R. (1986) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(86)90004-6 · Cited by 716
Heart wall motion: improved method of spatial modulation of magnetization for MR imaging.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.172.2.2748813 · Cited by 597
Cited by
Snakes, shapes, and gradient vector flow
Xu, C., & Prince, J. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661186 · Cited by 4,001
“Snakes are widely used in many applications, including edge detection [1], shape modeling [2], [3], segmentation [4], [5], and motion tracking [4], [6].”
BackgroundMethod4D Spatio-Temporal ConvNets: Minkowski Convolutional Neural Networks
Choy, C., Gwak, J., & Savarese, S. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00319 · Cited by 2,043
Deformable models in medical image analysis: a survey
McInerney, T., & Terzopoulos, D. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80007-7 · Cited by 1,913
Self-citationLane detection and tracking using B-Snake
Wang, Y., Teoh, E. K., & Shen, D. (2004) · Image and Vision Computing · doi:10.1016/j.imavis.2003.10.003 · Cited by 778
Generalized gradient vector flow external forces for active contours
Xu, C., & Prince, J. L. (1998) · Signal Processing · doi:10.1016/s0165-1684(98)00140-6 · Cited by 698
Zheng, Y., Barbu, A., Georgescu, B., Scheuering, M., & Comaniciu, D. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004421 · Cited by 546
Three-dimensional modeling for functional analysis of cardiac images, a review
Frangi, A. F., Niessen, W. J., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906421 · Cited by 533
Patient-Specific Modeling of Cardiovascular Mechanics
Taylor, C. A., & Figueroa, C. A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160521 · Cited by 451
T-snakes: Topology adaptive snakes
McInerney, T., & Terzopoulos, D. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00008-6 · Cited by 418
Self-citationAn algorithmic overview of surface registration techniques for medical imaging
Audette, M. A., Ferrie, F. P., & Peters, T. M. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00014-1 · Cited by 406
Active Contour External Force Using Vector Field Convolution for Image Segmentation
Li, B., & Acton, S. T. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.899601 · Cited by 393
Frangi, A. F., Rueckert, D., Schnabel, J. A., & Niessen, W. J. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804426 · Cited by 380
A review on brain tumor segmentation of MRI images
Wadhwa, A., Bhardwaj, A., & Singh Verma, V. (2019) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2019.05.043 · Cited by 374
Automatic Model-Based Segmentation of the Heart in CT Images
Ecabert, O., Peters, J., Schramm, H., Lorenz, C., von Berg, J., Walker, M. J., Vembar, M., Olszewski, M. E., Subramanyan, K., Lavi, G., et al. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.918330 · Cited by 368
Efficient and generalizable statistical models of shape and appearance for analysis of cardiac MRI
Andreopoulos, A., & Tsotsos, J. K. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.12.003 · Cited by 360
Deformable models in medical image analysis
McInerney, T., & Terzopoulos, D. (1996) · Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis · doi:10.1109/mmbia.1996.534069 · Cited by 329
Self-citationMa, Z., Tavares, J. M. R. S., Jorge, R. N., & Mascarenhas, T. (2010) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840903131878 · Cited by 316
An Adaptive Mesh Algorithm for Evolving Surfaces: Simulations of Drop Breakup and Coalescence
Cristini, V., Bławzdziewicz, J., & Loewenberg, M. (2001) · Journal of Computational Physics · doi:10.1006/jcph.2001.6713 · Cited by 223
“Adaptive mesh restructuring has applications in diverse fields, including medical imaging [ 32 , 33], computer graphics [11, 12], and geographical information systems [34].”
BackgroundComputational anatomy: shape, growth, and atrophy comparison via diffeomorphisms
Miller, M. I. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.021 · Cited by 196
“Automatic methods for maximum likelihood and Bayesian segmentation are being developed across the whole brain as well as focussing on particular gyri (Collins et al., 1995; CrespoFacorro et al., 2000; Dumoulin et al., 2003; Fischl et al., 2002, 2004a,b; Han et al., 2002; Joshi et al., 1999; Kikinis et al., 1996; McIne…”
BackgroundMethodInfluentialComputational modeling of cardiac hemodynamics: Current status and future outlook
Mittal, R., Seo, J. H., Vedula, V., Choi, Y. J., Liu, H., Huang, H. H., Jain, S., Younes, L., Abraham, T., & George, R. T. (2016) · Journal of Computational Physics · doi:10.1016/j.jcp.2015.11.022 · Cited by 194
“The mapping can in‐principle be accomplished by a variety of surface matching algorithms [62, 72, 73, 74, 75, 76, 77] but methods such as Iterative Closest Point (ICP) [78] and elastic deformation algorithms [79, 80] are not diffeomorphic and are only suitable for”
MethodProstate boundary segmentation from 2D ultrasound images
Ladak, H. M., Mao, F., Wang, Y., Downey, D. B., Steinman, D. A., & Fenster, A. (2000) · Medical Physics · doi:10.1118/1.1286722 · Cited by 177
Unsupervised Segmentation Based on Robust Estimation and Color Active Contour Models
Yang, L., Meer, P., & Foran, D. J. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.847515 · Cited by 169
Lynch, M., Ghita, O., & Whelan, P. F. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904681 · Cited by 164
“In the 4-D segmentation work described in Bardinet et al. [30] and also in McInerney et al. [ 31 ], the temporal dimension was considered in a sequential approach where the segmentation from the previous time frame was used as the initialization for the current time frame.”
Method
Metadata
- Authors
- McInerney, T., & Terzopoulos, D.
- Venue
- Computerized Medical Imaging and Graphics
- Publisher
- Elsevier BV
- Published
- 1995-01
- Volume
- 19
- Issue
- 1
- Pages
- 69-83
- ISSN
- 0730-4862 (ISSN-L)
- 0895-6111
- OpenAlex
- W1977574189
- Cited by
- 358
- References
- 17
- FWCI
- 17.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.