A planar IrO multichannel stimulating electrode for use in neural prostheses
Open accessThe claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Anodic Iridium Oxide Films: XPS‐Studies of Oxidation State Changes and
Kötz, R., Neff, H., & Stucki, S. (1984) · Journal of The Electrochemical Society · doi:10.1149/1.2115548 · Cited by 405 · see citing works
Activated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 228 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- F. T. Hambrecht and J. Reswick (eds.), Functional Electrical Stimulation: Amlication in Neutral Prostheses. Marcel Dekker, New Y&k, 1977.
Cited by
Sorted by citations
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276 · see citing works
Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1747881 · Cited by 154 · see citing works
Flexible Nerve Stimulation Electrode With Iridium Oxide Sputtered on Liquid Crystal Polymer
Wang, K., Liu, C.-C., & Durand, D. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.926691 · Cited by 57 · see citing works
- Authors
- Tanghe, S. J., Najafi, K., & Wise, K. D.
- Affiliations
- University of Michigan (US)
- ORCID
- Tanghe, S.J.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 1990-01
- Volume
- 1
- Issue
- 1-6
- Pages
- 464-467
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2162915851
- Cited by
- 47
- References
- 2
- Citations by year
- 2021: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2015: 1 · 2013: 1 · 2012: 1
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- Sensors and Actuators B Chemical (publishedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- National Institutes of Health
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- iridium oxide, neurostimulation, stimulating electrodes, neural prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review