Optogenetic reporters
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Fluorescent protein technology has evolved to include genetically-encoded biosensors that can monitor levels of ions, metabolites, and enzyme activities as well as protein conformation and even membrane voltage. They are well suited to live-cell microscopy and quantitative analysis, and they can be used in multiple imaging modes, including one or two-photon fluorescence intensity or lifetime microscopy. Although not nearly complete, there now exists a substantial set of genetically-encoded reporters that can be used to monitor many aspects of neuronal and glial biology, and these biosensors can be used to visualize synaptic transmission and activity-dependent signaling in vitro and in vivo. In this review we present an overview of design strategies for engineering biosensors, including sensor designs using circularly-permuted fluorescent proteins and using fluorescence resonance energy transfer (FRET) between fluorescent proteins. We also provide examples of indicators that sense small ions (e.g., pH, chloride, zinc), metabolites (e.g., glutamate, glucose, ATP, cAMP, lipid metabolites), signaling pathways (e.g., G protein coupled receptors, Rho GTPases), enzyme activities (e.g., protein kinase A, caspases), and reactive species. We focus on examples where these genetically-encoded indicators have been applied to brain-related studies and used with live-cell fluorescence microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Neuronal Subsets in Transgenic Mice Expressing Multiple Spectral Variants of GFP
Feng, G., Mellor, R. H., Bernstein, M., Keller-Peck, C., Nguyen, Q. T., Wallace, M., Nerbonne, J. M., Lichtman, J. W., & Sanes, J. R. (2000) · Neuron · doi:10.1016/s0896-6273(00)00084-2 · Cited by 3,042
Visualizing secretion and synaptic transmission with pH-sensitive green fluorescent proteins
Miesenböck, G., De Angelis, D. A., & Rothman, J. E. (1998) · Nature · doi:10.1038/28190 · Cited by 2,563
Reconciling the chemistry and biology of reactive oxygen species
Winterbourn, C. C. (2008) · Nature Chemical Biology · doi:10.1038/nchembio.85 · Cited by 2,504 · cited 1×
“Reactive Oxygen Species and Redox Potential Reactive oxygen species (ROS) and free radicals are generated in diverse metabolic processes, and they can often act as messengers in signal transduction by altering the reduction-oxidation (redox) status of various signaling proteins (Winterbourn, 2008).”
BackgroundNemani, V. M., Lu, W., Berge, V., Nakamura, K., Onoa, B., Lee, M. K., Chaudhry, F. A., Nicoll, R. A., & Edwards, R. H. (2010) · Neuron · doi:10.1016/j.neuron.2009.12.023 · Cited by 1,056
Nagai, T., Yamada, S., Tominaga, T., Ichikawa, M., & Miyawaki, A. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0400417101 · Cited by 1,030 · cited 1×
“Interestingly, cpFPs have been used to improve the dynamic range of the FRET response (Nagai et al., 2004).”
MethodPrinciples of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027 · cited 1×
“Combining GEIs with multiphoton imaging can be a powerful, non-invasive method for visualizing signaling dynamics in intact networks (Svoboda and Yasuda, 2006).”
MethodReducing the Environmental Sensitivity of Yellow Fluorescent Protein
Griesbeck, O., Baird, G. S., Campbell, R. E., Zacharias, D. A., & Tsien, R. Y. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m102815200 · Cited by 1,023
Hanson, G. T., Aggeler, R., Oglesbee, D., Cannon, M., Capaldi, R. A., Tsien, R. Y., & Remington, S. J. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m312846200 · Cited by 988 · cited 3×
“As reporters of general cellular redox status, redox-sensitive yellow FPs (rxYFPs) (Ostergaard et al., 2001) and redox-sensitive green FPs (roGFPs) (Hanson et al., 2004) have been created by engineering two surface-exposed cysteine residues near the chromophore.”
BackgroundMethodInfluentialReal-time imaging of the intracellular glutathione redox potential
Gutscher, M., Pauleau, A.-L., Marty, L., Brach, T., Wabnitz, G. H., Samstag, Y., Meyer, A. J., & Dick, T. P. (2008) · Nature Methods · doi:10.1038/nmeth.1212 · Cited by 894 · cited 1×
“For instance, while roGFP2 by itself reports the general cellular redox status, by linking roGFP2 to a human thioltransferase Grx1, a fluorescent reporter specific for glutathione redox has been created (Gutscher et al., 2008).”
BackgroundVárnai, P., & Balla, T. (1998) · The Journal of Cell Biology · doi:10.1083/jcb.143.2.501 · Cited by 859 · cited 1×
“PHPLCδ1-EGFP binds PIP2 in the membrane, but upon PIP2 hydrolysis to DAG and inositol-(1,4,5)-trisphosphate (IP3), PHPLCδ1-EGFP translocates to the cytoplasm (Stauffer et al., 1998; Varnai and Balla, 1998).”
Background
Cited by
Biosensor reveals multiple sources for mitochondrial NAD +
Cambronne, X. A., Stewart, M. L., Kim, D., Jones-Brunette, A. M., Morgan, R. K., Farrens, D. L., Cohen, M. S., & Goodman, R. H. (2016) · Science · doi:10.1126/science.aad5168 · Cited by 407
The ketogenic diet: metabolic influences on brain excitability and epilepsy
Lutas, A., & Yellen, G. (2013) · Trends in Neurosciences · doi:10.1016/j.tins.2012.11.005 · Cited by 321
Self-citationOptogenetic Tools for Subcellular Applications in Neuroscience
Rost, B. R., Schneider-Warme, F., Schmitz, D., & Hegemann, P. (2017) · Neuron · doi:10.1016/j.neuron.2017.09.047 · Cited by 317
Glucose, lactate, and shuttling of metabolites in vertebrate retinas
Hurley, J. B., Lindsay, K. J., & Du, J. (2015) · Journal of Neuroscience Research · doi:10.1002/jnr.23583 · Cited by 275
“New advances in fluorescent metabolite sensors may facilitate this (Tantama et al., 2012).”
BackgroundGlucose Regulates Mitochondrial Motility via Milton Modification by O-GlcNAc Transferase
Pekkurnaz, G., Trinidad, J. C., Wang, X., Kong, D., & Schwarz, T. L. (2014) · Cell · doi:10.1016/j.cell.2014.06.007 · Cited by 274
Juhas, M., Engelmayr, G. C., Fontanella, A. N., Palmer, G. M., & Bursac, N. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1402723111 · Cited by 246
“) (33, 34), we expect that similar experimental frameworks could allow real-time in vivo studies of various cellular processes of importance for the fields of stem-cell and cancer biology, tissue engineering, immunology, and others.”
BackgroundConnolly, N. M. C., Theurey, P., Adam-Vizi, V., Bazan, N. G., Bernardi, P., Bolaños, J. P., Culmsee, C., Dawson, V. L., Deshmukh, M., Duchen, M. R., et al. (2018) · Cell Death & Differentiation · doi:10.1038/s41418-017-0020-4 · Cited by 204
“Caveats for all genetically encoded fluorescent reporters include; sensitivity to environmental factors such as pH (can be corrected for with simultaneous use of a pH sensor), buffering of the target molecule (especially relevant for low abundance molecules), non-specificity (availability of negative controls is impor…”
BackgroundGenetic Approaches to Neural Circuits in the Mouse
Josh Huang, Z., & Zeng, H. (2013) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-062012-170307 · Cited by 200
Channel-Mediated Lactate Release by K+-Stimulated Astrocytes
Sotelo-Hitschfeld, T., Niemeyer, M. I., Mächler, P., Ruminot, I., Lerchundi, R., Wyss, M. T., Stobart, J., Fernández-Moncada, I., Valdebenito, R., Garrido-Gerter, P., et al. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.5036-14.2015 · Cited by 189
“Detailed protocols for the use of the fluorescent sensors are available (Hou et al., 2011; Tantama et al., 2012; Barros et al., 2014; San Martín et al., 2014b).”
MethodGenetically Encoded Voltage Indicators: Opportunities and Challenges
Yang, H. H., & St-Pierre, F. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.1095-16.2016 · Cited by 168
“Other indicators that could be paired with GEVIs for multimodal interrogation of brain tissue include sensors of neurotransmitters, pH, small-molecule metabolites, and enzymatic activity (Ibraheem and Campbell, 2010; Tantama et al., 2012; Broussard et al., 2014; Hochreiter et al., 2015).”
BackgroundAkt regulation of glycolysis mediates bioenergetic stability in epithelial cells
Hung, Y. P., Teragawa, C., Kosaisawe, N., Gillies, T. E., Pargett, M., Minguet, M., Distor, K., Rocha-Gregg, B. L., Coloff, J. L., Keibler, M. A., et al. (2017) · eLife · doi:10.7554/elife.27293 · Cited by 74
Self-citationMolecular neuroanatomy: a generation of progress
Pollock, J. D., Wu, D.-Y., & Satterlee, J. S. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2013.11.001 · Cited by 36
Metadata
- Authors
- Tantama, M., Hung, Y. P., & Yellen, G.
- Venue
- Progress in Brain Research
- Publisher
- Elsevier
- Published
- 2012
- Volume
- 196
- Pages
- 235-263
- ISSN
- 0079-6123 (ISSN-L)
- OpenAlex
- W1559330503
- Cited by
- 61
- References
- 18
- FWCI
- 10.00
- Type
- book chapter
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.