Brain-computer interfaces: Definitions and principles
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Throughout life, the central nervous system (CNS) interacts with the world and with the body by activating muscles and excreting hormones. In contrast, brain-computer interfaces (BCIs) quantify CNS activity and translate it into new artificial outputs that replace, restore, enhance, supplement, or improve the natural CNS outputs. BCIs thereby modify the interactions between the CNS and the environment. Unlike the natural CNS outputs that come from spinal and brainstem motoneurons, BCI outputs come from brain signals that represent activity in other CNS areas, such as the sensorimotor cortex. If BCIs are to be useful for important communication and control tasks in real life, the CNS must control these brain signals nearly as reliably and accurately as it controls spinal motoneurons. To do this, they might, for example, need to incorporate software that mimics the function of the subcortical and spinal mechanisms that participate in normal movement control. The realization of high reliability and accuracy is perhaps the most difficult and critical challenge now facing BCI research and development. The ongoing adaptive modifications that maintain effective natural CNS outputs take place primarily in the CNS. The adaptive modifications that maintain effective BCI outputs can also take place in the BCI. This means that the BCI operation depends on the effective collaboration of two adaptive controllers, the CNS and the BCI. Realization of this second adaptive controller, the BCI, and management of its interactions with concurrent adaptations in the CNS comprise another complex and critical challenge for BCI development. BCIs can use different kinds of brain signals recorded in different ways from different brain areas. Decisions about which signals recorded in which ways from which brain areas should be selected for which applications are empirical questions that can only be properly answered by experiments. BCIs, like other communication and control technologies, often face artifacts that contaminate or imitate their chosen signals. Noninvasive BCIs (e.g., EEG- or fNIRS-based) need to take special care to avoid interpreting nonbrain signals (e.g., cranial EMG) as brain signals. This typically requires comprehensive topographical and spectral evaluations. In theory, the outputs of BCIs can select a goal or control a process. In the future, the most effective BCIs will probably be those that combine goal selection and process control so as to distribute control between the BCI and the application in a fashion suited to the current action. Through such distribution, BCIs may most effectively imitate natural CNS operation. The primary measure of BCI development is the extent to which BCI systems benefit people with neuromuscular disorders. Thus, BCI clinical evaluation, validation, and dissemination is a key step. It is at the same time a complex and difficult process that depends on multidisciplinary collaboration and management of the demanding requirements of clinical studies. Twenty-five years ago, BCI research was an esoteric endeavor pursued in only a few isolated laboratories. It is now a steadily growing field that engages many hundreds of scientists, engineers, and clinicians throughout the world in an increasingly interconnected community that is addressing the key issues and pursuing the high potential of BCI technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Self-citationNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Self-citationElectroencephalographic (EEG) control of three-dimensional movement
McFarland, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/3/036007 · Cited by 454
Self-citationIndependent home use of a brain-computer interface by people with amyotrophic lateral sclerosis
Wolpaw, J. R., Bedlack, R. S., Reda, D. J., Ringer, R. J., Banks, P. G., Vaughan, T. M., Heckman, S. M., McCane, L. M., Carmack, C. S., Winden, S., et al. (2018) · Neurology · doi:10.1212/wnl.0000000000005812 · Cited by 170
Self-citationThe Cybathlon BCI race: Successful longitudinal mutual learning with two tetraplegic users
Perdikis, S., Tonin, L., Saeedi, S., Schneider, C., & Millán, J. D. R. (2018) · PLOS Biology · doi:10.1371/journal.pbio.2003787 · Cited by 166
Self-citationRegulation of spine and synapse formation by activity-dependent intracellular signaling pathways
Saneyoshi, T., Fortin, D. A., & Soderling, T. R. (2010) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2009.09.013 · Cited by 133
Brain-Machine Interfaces: The Perception-Action Closed Loop: A Two-Learner System
Millan, J. D. R. (2015) · IEEE Systems, Man, and Cybernetics Magazine · doi:10.1109/msmc.2014.2386901 · Cited by 19
Cited by
Implantable brain machine interfaces: first-in-human studies, technology challenges and trends
Rapeaux, A. B., & Constandinou, T. G. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.10.001 · Cited by 119
The ethical significance of user-control in AI-driven speech-BCIs: a narrative review
van Stuijvenberg, O. C., Samlal, D. P. S., Vansteensel, M. J., Broekman, M. L. D., & Jongsma, K. R. (2024) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2024.1420334 · Cited by 13
“Guidance control would thus go beyond selecting goals and initiating processes as done by executory control but would rather govern the implementation of speech (Rainey et al., 2019; Wolpaw et al., 2020; Maslen and Rainey, 2021).”
Background
Metadata
- Venue
- Handbook of Clinical Neurology
- Publisher
- Elsevier
- Published
- 2020
- Volume
- 168
- Pages
- 15-23
- ISSN
- 0072-9752 (ISSN-L)
- OpenAlex
- W3011231084
- Cited by
- 178
- References
- 9
- FWCI
- 46.87
- Type
- book chapter
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Brain-computer interfaces: Definitions and principles. https://app.cochat.ai/papers/10.1016/b978-0-444-63934-9.00002-0
- The paper
- Brain-computer interfaces: Definitions and principles. (2020). Handbook of Clinical Neurology. https://doi.org/10.1016/b978-0-444-63934-9.00002-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.