Abstract
OBJECTIVE: To assess the reliability and usefulness of an EEG-based brain-computer interface (BCI) for patients with advanced amyotrophic lateral sclerosis (ALS) who used it independently at home for up to 18 months. METHODS: Of 42 patients consented, 39 (93%) met the study criteria, and 37 (88%) were assessed for use of the Wadsworth BCI. Nine (21%) could not use the BCI. Of the other 28, 27 (men, age 28-79 years) (64%) had the BCI placed in their homes, and they and their caregivers were trained to use it. Use data were collected by Internet. Periodic visits evaluated BCI benefit and burden and quality of life. RESULTS: Over subsequent months, 12 (29% of the original 42) left the study because of death or rapid disease progression and 6 (14%) left because of decreased interest. Fourteen (33%) completed training and used the BCI independently, mainly for communication. Technical problems were rare. Patient and caregiver ratings indicated that BCI benefit exceeded burden. Quality of life remained stable. Of those not lost to the disease, half completed the study; all but 1 patient kept the BCI for further use. CONCLUSION: The Wadsworth BCI home system can function reliably and usefully when operated by patients in their homes. BCIs that support communication are at present most suitable for people who are severely disabled but are otherwise in stable health. Improvements in BCI convenience and performance, including some now underway, should increase the number of people who find them useful and the extent to which they are used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“EEG spellers based on oddball potentials or motor imagery typically achieve 1–5 characters per minute28–32.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [32]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Brain–computer interface–based communication in the completely locked-in State
Chaudhary, U., Xia, B., Silvoni, S., Cohen, L. G., & Birbaumer, N. (2017) · PLOS Biology · doi:10.1371/journal.pbio.1002593 · Cited by 235
RetractedEl Escorial revisited: revised criteria for the diagnosis of amyotrophic lateral sclerosis
Brooks, B. R., Miller, R. G., Swash, M., & Munsat, T. L. (2000) · Amyotrophic Lateral Sclerosis and Other Motor Neuron Disorders · doi:10.1080/146608200300079536 · Cited by 5,433
Cedarbaum, J. M., Stambler, N., Malta, E., Fuller, C., Hilt, D., Thurmond, B., & Nakanishi, A. (1999) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(99)00210-5 · Cited by 3,307
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“Thus, BCIs that can preserve communication might affect clinical recommendations and patient decisions.(1,11,12)”
BackgroundBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Self-citationA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Brain–Computer InterfacesPrinciples and Practice
Wolpaw, J., & Wolpaw, E. W. (2012) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195388855.001.0001 · Cited by 1,104
Self-citationAmerican Electroencephalographic Society Guidelines for Standard Electrode Position Nomenclature
&NA; (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199104000-00007 · Cited by 1,050
Brain–computer interfaces for communication and rehabilitation
Chaudhary, U., Birbaumer, N., & Ramos-Murguialday, A. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.113 · Cited by 928
American Electroencephalographic Society guidelines for standard electrode position nomenclature
Sharbrough, F. W. (1991) · Journal of Clinical Neurophysiology · Cited by 918
Research works printed but not linked: 3
- Institute of Medicine. Amyotrophic Lateral Sclerosis in Veterans: Review of the Scientific Literature. Washington: National Academies Press; 2006.
- US Department of Veterans Affairs, National Center for Veterans Analysis and Statistics. Available at: va.gov/vetdata/veteranpopulation.asp (table 6L). Accessed June 2018.
- Ball LJ, Nordness AS, Fager SK, et al. Eye-gaze access to AAC technology for people with amyotrophic lateral sclerosis. J Med Speech Lang Pathol 2010;18:11–23.
Cited by
High-performance brain-to-text communication via handwriting
Willett, F. R., Avansino, D. T., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2021) · Nature · doi:10.1038/s41586-021-03506-2 · Cited by 1,024
“Commonly used BCIs for restoring communication are either flashing electroencephalogram (EEG) spellers 18,28–32 or intracortical point-and-click BCIs 6,7,33 .”
BackgroundMethodNeuroprosthesis for Decoding Speech in a Paralyzed Person with Anarthria
Moses, D. A., Metzger, S. L., Liu, J. R., Anumanchipalli, G. K., Makin, J. G., Sun, P. F., Chartier, J., Dougherty, M. E., Liu, P. M., Abrams, G. M., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2027540 · Cited by 582
“In previously reported brain–computer interface applications, decoding models often require daily recalibration before deployment with a user,(6,35) which can increase the variability of decoder performance across days and impede longterm adoption of the interface for real-world use.(35,36) Because of the relatively h…”
BackgroundBrain-computer interfaces: Definitions and principles
(2020) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-63934-9.00002-0 · Cited by 178
Self-citationCurrent State and Future Directions in the Therapy of ALS
Tzeplaeff, L., Wilfling, S., Requardt, M. V., & Herdick, M. (2023) · Cells · doi:10.3390/cells12111523 · Cited by 148
Chaudhary, U., Vlachos, I., Zimmermann, J. B., Espinosa, A., Tonin, A., Jaramillo-Gonzalez, A., Khalili-Ardali, M., Topka, H., Lehmberg, J., Friehs, G. M., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-28859-8 · Cited by 139
Metadata
- Authors
- Wolpaw, J. R., Bedlack, R. S., Reda, D. J., Ringer, R. J., Banks, P. G., Vaughan, T. M., Heckman, S. M., McCane, L. M., Carmack, C. S., Winden, S., McFarland, D. J., Sellers, E. W., Shi, H., Paine, T., Higgins, D. S., Lo, A. C., Patwa, H. S., Hill, K. J., Huang, G. D., & Ruff, R. L.
- Affiliations
- New York State Department of Health (US)
- ORCID
- Venue
- Neurology
- Published
- 2018-07-17
- Volume
- 91
- Issue
- 3
- Pages
- e258-e267
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- PMC
- PMC6059033
- OpenAlex
- W2810837951
- Cited by
- 170
- References
- 45
- Citations by year
- 2026: 9 · 2025: 41 · 2024: 13 · 2023: 14 · 2022: 21 · 2021: 26 · 2020: 24 · 2019: 18 · 2018: 4
- FWCI
- 10.70
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Neurology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Digital Commons - East Tennessee State University (East Tennessee State University) (submittedVersion)
- Funders
- U.S. Department of Veterans Affairs
- National Institute of Biomedical Imaging and Bioengineering (P41EB018783)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Keywords
- brain-computer interface, amyotrophic lateral sclerosis, EEG-based BCI, communication aids, caregiver education, quality of life, severely disabled patients
- MeSH terms
- Adult, Aged, Amyotrophic Lateral Sclerosis, Electroencephalography, Home Care Services, Humans, Male, Middle Aged, Self Care, Therapy, Computer-Assisted, United States, United States Department of Veterans Affairs, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Independent home use of a brain-computer interface by people with amyotrophic lateral sclerosis. https://app.cochat.ai/papers/10.1212/wnl.0000000000005812
- The paper
- Wolpaw, J. R., Bedlack, R. S., Reda, D. J., Ringer, R. J., Banks, P. G., Vaughan, T. M., Heckman, S. M., McCane, L. M., Carmack, C. S., Winden, S., McFarland, D. J., Sellers, E. W., Shi, H., Paine, T., Higgins, D. S., Lo, A. C., Patwa, H. S., Hill, K. J., Huang, G. D., & Ruff, R. L. (2018). Independent home use of a brain-computer interface by people with amyotrophic lateral sclerosis. Neurology. https://doi.org/10.1212/wnl.0000000000005812
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.