An effective method for fast determination of artemisinin in Artemisia annua L. by high performance liquid chromatography with evaporative light scattering detection
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Artemisinin isolated from the aerial parts of Artemisia annua L., is a promising and potent antimalarial drug, which meets the dual challenge posed by drug-resistant parasites and rapid progression of malarial illness. The aim of the current study was to develop a reliable and fast analytical procedure for the determination of artemisinin in A. annua using high performance liquid chromatography (HPLC) with evaporative light scattering detection (ELSD) in couple with microwave-assisted extraction (MAE) as an efficient sample preparation technique. The HPLC conditions were Agilent C18 column using water:acetonitrile (40:60 v/v) mixture as mobile phase at a flow rate of 1 mL min(-1). ELSD conditions were optimized at nebulizer-gas flow rate of 2.0 L min(-1) and drift tube temperature of 70 degrees C under the impactor off-mode, and the gain was set at 2. Afterwards, method validation system for HPLC-ELSD analysis was developed. Calibration range was 0.2-1.0 mg mL(-1) and correlation coefficient r was above 0.9990. Precision experiments showed relative standard deviation (R.S.D.) of retention time was less than 0.5% and R.S.D. of peak area was less than 1.30%. Inter-day and intra-day variabilities showed that R.S.D. was ranged from 1.01% to 4.66%. Limit of detection was less than 40 microg mL(-1) and limit of quantification was less than 100 microg mL(-1). Accuracy validation showed that average recovery was between 98.23% and 104.97%. The developed analytical procedure was successfully applied to determine the contents of artemisinin in the different parts of A. annua plants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ferreira, J., Simon, J., & Janick, J. (1995) · Planta Medica · doi:10.1055/s-2006-958040 · Cited by 128
Cited by
Bagade, S. B., & Patil, M. (2021) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2019.1686966 · Cited by 322
Chemical markers for the quality control of herbal medicines: an overview
Li, S., Han, Q., Qiao, C., Song, J., Lung Cheng, C., & Xu, H. (2008) · Chinese Medicine · doi:10.1186/1749-8546-3-7 · Cited by 310
Sesquiterpene Lactones from Artemisia Genus: Biological Activities and Methods of Analysis
Ivanescu, B., Miron, A., & Corciova, A. (2015) · Journal of Analytical Methods in Chemistry · doi:10.1155/2015/247685 · Cited by 201
“On the other hand, its sensitivity is lower than other detection methods, such as ECD and MS [113, 138, 139].”
BackgroundMethodDevelopment of HPLC analytical protocols for quantification of artemisinin in biomass and extracts
Lapkin, A. A., Walker, A., Sullivan, N., Khambay, B., Mlambo, B., & Chemat, S. (2009) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2009.01.025 · Cited by 78
Sixt, M., Schmidt, A., Mestmäcker, F., Huter, M. J., Uhlenbrock, L., & Strube, J. (2018) · Processes · doi:10.3390/pr6090161 · Cited by 25
Metadata
- Authors
- Liu, C.-Z., Zhou, H.-Y., & Zhao, Y.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2007-01
- Volume
- 581
- Issue
- 2
- Pages
- 298-302
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2058902441
- Cited by
- 69
- References
- 1
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.