The DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Recent trends in carbon nanomaterial-based electrochemical sensors for biomolecules: A review
Open accessAbstract
Carbon nanomaterials are advantageous for electrochemical sensors because they increase the electroactive surface area, enhance electron transfer, and promote adsorption of molecules. Carbon nanotubes (CNTs) have been incorporated into electrochemical sensors for biomolecules and strategies have included the traditional dip coating and drop casting methods, direct growth of CNTs on electrodes and the use of CNT fibers and yarns made exclusively of CNTs. Recent research has also focused on utilizing many new types of carbon nanomaterials beyond CNTs. Forms of graphene are now increasingly popular for sensors including reduced graphene oxide, carbon nanohorns, graphene nanofoams, graphene nanorods, and graphene nanoflowers. In this review, we compare different carbon nanomaterial strategies for creating electrochemical sensors for biomolecules. Analytes covered include neurotransmitters and neurochemicals, such as dopamine, ascorbic acid, and serotonin; hydrogen peroxide; proteins, such as biomarkers; and DNA. The review also addresses enzyme-based electrodes that are used to detect non-electroactive species such as glucose, alcohols, and proteins. Finally, we analyze some of the future directions for the field, pointing out gaps in fundamental understanding of electron transfer to carbon nanomaterials and the need for more practical implementation of sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
Geim, A. K., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1849 · Cited by 39,979
Two-dimensional gas of massless Dirac fermions in graphene
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Katsnelson, M. I., Grigorieva, I. V., Dubonos, S. V., & Firsov, A. A. (2005) · Nature · doi:10.1038/nature04233 · Cited by 21,611
Advanced Carbon Electrode Materials for Molecular Electrochemistry
McCreery, R. L. (2008) · Chemical Reviews · doi:10.1021/cr068076m · Cited by 2,729
Poland, C. A., Duffin, R., Kinloch, I., Maynard, A., Wallace, W. A. H., Seaton, A., Stone, V., Brown, S., MacNee, W., & Donaldson, K. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.111 · Cited by 2,645 · cited 1×
“Currently, many studies of CNT toxicity have examined the effects of inhalation of CNTs and these studies suggest that CNTs aggregates may act similarly to asbestos.[156] MWCNTs have been shown to be more resistant to phagocytosis and longer CNTs are more difficult to clear than short CNTs.”
BackgroundMacroscopic Fibers and Ribbons of Oriented Carbon Nanotubes
Vigolo, B., Pénicaud, A., Coulon, C., Sauder, C., Pailler, R., Journet, C., Bernier, P., & Poulin, P. (2000) · Science · doi:10.1126/science.290.5495.1331 · Cited by 1,851
Reducing Sugar: New Functional Molecules for the Green Synthesis of Graphene Nanosheets
Zhu, C., Guo, S., Fang, Y., & Dong, S. (2010) · ACS Nano · doi:10.1021/nn1002387 · Cited by 1,442
Review: Carbon nanotube based electrochemical sensors for biomolecules
Jacobs, C. B., Peairs, M. J., & Venton, B. J. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.01.009 · Cited by 987
Self-citationNanomaterials based electrochemical sensors for biomedical applications
Chen, A., & Chatterjee, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35518g · Cited by 956
Sheng, Z.-H., Zheng, X.-Q., Xu, J.-Y., Bao, W.-J., Wang, F.-B., & Xia, X.-H. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.01.030 · Cited by 748
Cited by
Molecular imprinting: perspectives and applications
Chen, L., Wang, X., Lu, W., Wu, X., & Li, J. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00061d · Cited by 2,460
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Microbial fuel cells: An overview of current technology
Slate, A. J., Whitehead, K. A., Brownson, D. A. C., & Banks, C. E. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.09.044 · Cited by 725
Review—Recent Advances in Carbon Nanomaterials as Electrochemical Biosensors
Kour, R., Arya, S., Young, S.-J., Gupta, V., Bandhoria, P., & Khosla, A. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab6bc4 · Cited by 424
Qian, L., Durairaj, S., Prins, S., & Chen, A. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112836 · Cited by 396
Bolotsky, A., Butler, D., Dong, C., Gerace, K., Glavin, N. R., Muratore, C., Robinson, J. A., & Ebrahimi, A. (2019) · ACS Nano · doi:10.1021/acsnano.9b03632 · Cited by 381
Zhang, R., & Chen, W. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.01.080 · Cited by 368
Recent advances in carbon nanomaterials-based electrochemical sensors for food azo dyes detection
Karimi-Maleh, H., Beitollahi, H., Senthil Kumar, P., Tajik, S., Mohammadzadeh Jahani, P., Karimi, F., Karaman, C., Vasseghian, Y., Baghayeri, M., Rouhi, J., et al. (2022) · Food and Chemical Toxicology · doi:10.1016/j.fct.2022.112961 · Cited by 367
Fundamentals of fast-scan cyclic voltammetry for dopamine detection
Venton, B. J., & Cao, Q. (2020) · The Analyst · doi:10.1039/c9an01586h · Cited by 357
Self-citationZhang, X., Zhang, Y.-C., & Ma, L.-X. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.12.073 · Cited by 339
Recent Advances in Sensing Applications of Graphene Assemblies and Their Composites
Tung, T. T., Nine, M. J., Krebsz, M., Pasinszki, T., Coghlan, C. J., Tran, D. N. H., & Losic, D. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702891 · Cited by 294
Balanced Resistive Matrix Array for High-Density Electrochemical Sensor Array
Park, H., Sun, Y., & Jung, S. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3274645 · Cited by 4
Metadata
- Authors
- Yang, C., Denno, M. E., Pyakurel, P., & Venton, B. J.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2015-08
- Volume
- 887
- Pages
- 17-37
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W768012932
- Cited by
- 577
- References
- 95
- FWCI
- 22.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.