The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Technical aspects and challenges of colorimetric detection with microfluidic paper-based analytical devices (μPADs) - A review
Open accessAbstract
Paper-based devices are a leading alternative among the main analytical tools for point-of-care testing, due to their portability, low-cost, and ease-of-use. Colorimetric readouts are the most common method of detection in these microfluidic devices, enabling qualitative, semi-quantitative and fully quantitative analysis of multiple analytes. There is a multitude of ways to obtain a colorimetric output in such devices, including nanoparticles, dyes, redox and pH indicators, and each has unique drawbacks and benefits. There are also multiple variables that impact the analysis of colorimetric reactions in microfluidic paper-based systems, including color homogeneity, image capture methods, and the data handling itself. Here, we present a critical review of recent developments and challenges of colorimetric detection on microfluidic paper-based analytical devices (μPADs), and present thoughts and insights towards future perspectives in the area to improve the use of colorimetric readouts in conjunction with μPADs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new and rapid colorimetric determination of acetylcholinesterase activity
Ellman, G. L., Courtney, K. D., Andres, V., & Featherstone, R. M. (1961) · Biochemical Pharmacology · doi:10.1016/0006-2952(61)90145-9 · Cited by 27,126
Kelly, K. L., Coronado, E., Zhao, L. L., & Schatz, G. C. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp026731y · Cited by 10,594
Surface Plasmon Spectroscopy of Nanosized Metal Particles
Mulvaney, P. (1996) · Langmuir · doi:10.1021/la9502711 · Cited by 3,681
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Self-citationHuang, X., & El-Sayed, M. A. (2010) · Journal of Advanced Research · doi:10.1016/j.jare.2010.02.002 · Cited by 2,192
X. The Bakerian Lecture. —Experimental relations of gold (and other metals) to light
Faraday, M. (1857) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1857.0011 · Cited by 2,123
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Spot Tests in Organic Analysis
(1966) · Elsevier eBooks · doi:10.1016/c2009-0-07233-x · Cited by 1,759
Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Self-citationCharacteristics of the Iodide/Triiodide Redox Mediator in Dye-Sensitized Solar Cells
Boschloo, G., & Hagfeldt, A. (2009) · Accounts of Chemical Research · doi:10.1021/ar900138m · Cited by 1,468
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Self-citationSynthesis and applications of silver nanoparticles
Abou El-Nour, K. M. M., Eftaiha, A., Al-Warthan, A., & Ammar, R. A. A. (2010) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2010.04.008 · Cited by 1,354
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Synthesis and Study of Silver Nanoparticles
Mulfinger, L., Solomon, S. D., Bahadory, M., Jeyarajasingam, A. V., Rutkowsky, S. A., & Boritz, C. (2007) · Journal of Chemical Education · doi:10.1021/ed084p322 · Cited by 1,154
Josephy, P. D., Eling, T., & Mason, R. P. (1982) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)34832-4 · Cited by 966
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
A perspective on paper-based microfluidics: Current status and future trends
Li, X., Ballerini, D. R., & Shen, W. (2012) · Biomicrofluidics · doi:10.1063/1.3687398 · Cited by 813
The use of gold nanoparticles in diagnostics and detection
Wilson, R. (2008) · Chemical Society Reviews · doi:10.1039/b712179m · Cited by 671
Factors affecting short-term and long-term stabilities of proteins
Arakawa, T., Prestrelski, S. J., Kenney, W. C., & Carpenter, J. F. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00144-7 · Cited by 640
Point-of-care colorimetric detection with a smartphone
Shen, L., Hagen, J. A., & Papautsky, I. (2012) · Lab on a Chip · doi:10.1039/c2lc40741h · Cited by 609
Rapid tests for sexually transmitted infections (STIs): the way forward
Peeling, R. W., Holmes, K. K., Mabey, D., & Ronald, A. (2006) · Sexually Transmitted Infections · doi:10.1136/sti.2006.024265 · Cited by 599
Nanoparticle-based lateral flow biosensors
Quesada-González, D., & Merkoçi, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.050 · Cited by 597
Bioactive paper provides a low-cost platform for diagnostics
Pelton, R. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.05.005 · Cited by 562
Chen, G.-H., Chen, W.-Y., Yen, Y.-C., Wang, C.-W., Chang, H.-T., & Chen, C.-F. (2014) · Analytical Chemistry · doi:10.1021/ac5008688 · Cited by 508
Electrochemical analysis of the interactions of laccase mediators with lignin model compounds
Bourbonnais, R., Leech, D., & Paice, M. G. (1998) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(97)00117-7 · Cited by 493
Colorimetric Sensor Arrays for Volatile Organic Compounds
Janzen, M. C., Ponder, J. B., Bailey, D. P., Ingison, C. K., & Suslick, K. S. (2006) · Analytical Chemistry · doi:10.1021/ac052111s · Cited by 491
Principles and Techniques of Diffuse‐Reflectance Spectroscopy
Kortüm, G., Braun, W., & Herzog, G. (1963) · Angewandte Chemie International Edition in English · doi:10.1002/anie.196303331 · Cited by 437
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Lopez-Ruiz, N., Curto, V. F., Erenas, M. M., Benito-Lopez, F., Diamond, D., Palma, A. J., & Capitan-Vallvey, L. F. (2014) · Analytical Chemistry · doi:10.1021/ac5019205 · Cited by 423
Steenken, S., & Neta, P. (1982) · The Journal of Physical Chemistry · doi:10.1021/j100215a033 · Cited by 414
The Absorption Spectra of I2, I3-, I-, IO3-, S4O6= and S2O3=. Heat of the Reaction I3- = I2 + I-
Awtrey, A. D., & Connick, R. E. (1951) · Journal of the American Chemical Society · doi:10.1021/ja01148a504 · Cited by 388
Use of multiple colorimetric indicators for paper-based microfluidic devices
Dungchai, W., Chailapakul, O., & Henry, C. S. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.06.019 · Cited by 364
Smartphone based health accessory for colorimetric detection of biomarkers in sweat and saliva
Oncescu, V., O'Dell, D., & Erickson, D. (2013) · Lab on a Chip · doi:10.1039/c3lc50431j · Cited by 362
Simple, distance-based measurement for paper analytical devices
Cate, D. M., Dungchai, W., Cunningham, J. C., Volckens, J., & Henry, C. S. (2013) · Lab on a Chip · doi:10.1039/c3lc50072a · Cited by 348
Recent developments in computer vision-based analytical chemistry: A tutorial review
Capitán-Vallvey, L. F., López-Ruiz, N., Martínez-Olmos, A., Erenas, M. M., & Palma, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.10.009 · Cited by 341
Spot tests in organic analysis
Feigl, F., ANGER, V., & Oesper, R. E. (1966) · Cited by 331
Charged Gold Nanoparticles in Non-Polar Solvents: 10-min Synthesis and 2D Self-Assembly
Martin, M. N., Basham, J. I., Chando, P., & Eah, S.-K. (2010) · Langmuir · doi:10.1021/la100591h · Cited by 328
A Paper-Based Multiplexed Transaminase Test for Low-Cost, Point-of-Care Liver Function Testing
Pollock, N. R., Rolland, J. P., Kumar, S., Beattie, P. D., Jain, S., Noubary, F., Wong, V. L., Pohlmann, R. A., Ryan, U. S., & Whitesides, G. M. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003981 · Cited by 326
Sola-Penna, M., & Meyer-Fernandes, J. R. (1998) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.1998.0906 · Cited by 319
Hossain, S. M. Z., Luckham, R. E., McFadden, M. J., & Brennan, J. D. (2009) · Analytical Chemistry · doi:10.1021/ac901714h · Cited by 316
Yen, C.-W., de Puig, H., Tam, J. O., Gómez-Márquez, J., Bosch, I., Hamad-Schifferli, K., & Gehrke, L. (2015) · Lab on a Chip · doi:10.1039/c5lc00055f · Cited by 308
Paper-based analytical devices for environmental analysis
Meredith, N. A., Quinn, C., Cate, D. M., Reilly, T. H., Volckens, J., & Henry, C. S. (2016) · The Analyst · doi:10.1039/c5an02572a · Cited by 299
β-Galactosidase-Based Colorimetric Paper Sensor for Determination of Heavy Metals
Hossain, S. M. Z., & Brennan, J. D. (2011) · Analytical Chemistry · doi:10.1021/ac202290d · Cited by 297
Mobile phone-based biosensing: An emerging “diagnostic and communication” technology
Quesada-González, D., & Merkoçi, A. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.062 · Cited by 272
de Tarso Garcia, P., Garcia Cardoso, T. M., Garcia, C. D., Carrilho, E., & Tomazelli Coltro, W. K. (2014) · RSC Adv. · doi:10.1039/c4ra07112c · Cited by 241
Self-citationLisowski, P., & Zarzycki, P. K. (2013) · Chromatographia · doi:10.1007/s10337-013-2413-y · Cited by 239
Gabriel, E. F. M., Garcia, P. T., Cardoso, T. M. G., Lopes, F. M., Martins, F. T., & Coltro, W. K. T. (2016) · The Analyst · doi:10.1039/c6an00430j · Cited by 204
Yang, K., Peretz-Soroka, H., Liu, Y., & Lin, F. (2016) · Lab on a Chip · doi:10.1039/c5lc01524c · Cited by 198
Optimization of a Paper-Based ELISA for a Human Performance Biomarker
Murdock, R. C., Shen, L., Griffin, D. K., Kelley-Loughnane, N., Papautsky, I., & Hagen, J. A. (2013) · Analytical Chemistry · doi:10.1021/ac403040a · Cited by 184
Determination of nitrite in saliva using microfluidic paper-based analytical devices
Bhakta, S. A., Borba, R., Taba, M., Garcia, C. D., & Carrilho, E. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.11.044 · Cited by 173
Self-citationModification of microfluidic paper-based devices with silica nanoparticles
Evans, E., Moreira Gabriel, E. F., Benavidez, T. E., Tomazelli Coltro, W. K., & Garcia, C. D. (2014) · The Analyst · doi:10.1039/c4an01147c · Cited by 173
“Fluidic batteries” as low-cost sources of power in paper-based microfluidic devices
Thom, N. K., Yeung, K., Pillion, M. B., & Phillips, S. T. (2012) · Lab on a Chip · doi:10.1039/c2lc40126f · Cited by 161
Kadnikova, E. N., & Kostić, N. M. (2002) · Journal of Molecular Catalysis B Enzymatic · doi:10.1016/s1381-1177(02)00057-7 · Cited by 151
Wang, H., Li, Y., Wei, J., Ji-run, X., Wang, Y., & Zheng, G. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7715-x · Cited by 125
Lan, J., Xu, W.-M., Wan, Q., et al. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.040 · Cited by 125
Applications of everyday IT and communications devices in modern analytical chemistry: A review
Grudpan, K., Kolev, S. D., Lapanantnoppakhun, S., McKelvie, I. D., & Wongwilai, W. (2015) · Talanta · doi:10.1016/j.talanta.2014.12.042 · Cited by 120
A simple and smart telemedicine device for developing regions: a pocket-sized colorimetric reader
Lee, D.-S., Jeon, B. G., Ihm, C., Park, J., & Jung, M. Y. (2010) · Lab on a Chip · doi:10.1039/c0lc00209g · Cited by 112
Thom, N. K., Lewis, G. G., Yeung, K., & Phillips, S. T. (2013) · RSC Advances · doi:10.1039/c3ra44717k · Cited by 109
Paper-based glucose biosensing system utilizing a smartphone as a signal reader
Chun, H. J., Park, Y. M., Han, Y. D., Jang, Y. H., & Yoon, H. C. (2014) · BioChip Journal · doi:10.1007/s13206-014-8308-7 · Cited by 104
Paper-based tuberculosis diagnostic devices with colorimetric gold nanoparticles
Tsai, T., Shen, S., Cheng, C., & Chen, C. (2013) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/14/4/044404 · Cited by 102
Lee, S., Mehta, S., & Erickson, D. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01828 · Cited by 101
Microfluidic Paper-Based Devices for Bioanalytical Applications
Santhiago, M., Nery, E. W., dos Santos, G. P., & Kubota, L. T. (2013) · Bioanalysis · doi:10.4155/bio.13.296 · Cited by 99
Choleva, T. G., Kappi, F. A., Giokas, D. L., & Vlessidis, A. G. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.12.025 · Cited by 88
Biomedical imaging and sensing using flatbed scanners
Göröcs, Z. S., & Özcan, A. (2014) · Lab on a Chip · doi:10.1039/c4lc00530a · Cited by 61
Mobile App-Based Quantitative Scanometric Analysis
Wong, J. X. H., Liu, F. S. F., & Yu, H. (2014) · Analytical Chemistry · doi:10.1021/ac5035727 · Cited by 61
Development and statistical assessment of a paper-based immunoassay for detection of tumor markers
Mazzu-Nascimento, T., Morbioli, G. G., Milan, L. A., Donofrio, F. C., Mestriner, C. A., & Carrilho, E. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.11.011 · Cited by 53
Self-citationPaper-based standard addition assays
Chaplan, C. A., Mitchell, H. T., & Martinez, A. W. (2014) · Analytical Methods · doi:10.1039/c4ay00205a · Cited by 52
Sample Preparation: An Analytical Perspective
Mitra, S., & Brukh, R. (2003) · Wiley eBooks · doi:10.1002/0471457817.ch1 · Cited by 51
McCracken, K. E., Angus, S. V., Reynolds, K. A., & Yoon, J. (2016) · Scientific Reports · doi:10.1038/srep27529 · Cited by 47
Thermal stability of bioactive enzymatic papers
Khan, M. S., Li, X., Shen, W., & Garnier, G. (2009) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2009.08.042 · Cited by 45
Paper-Based Systems for Point-of-Care Biosensing
Cheung, S. F., Cheng, S. K. L., & Kamei, D. T. (2015) · SLAS TECHNOLOGY · doi:10.1177/2211068215577197 · Cited by 43
A novel enzymatic technique for determination of sarcosine in urine samples
Burton, C., Gamagedara, S., & Ma, Y. (2011) · Analytical Methods · doi:10.1039/c1ay05541k · Cited by 39
Detection of propranolol in pharmaceutical formulations by diffuse reflectance spectroscopy
Gotardo, M. A., Tognolli, J. O., Pezza, H. R., & Pezza, L. (2007) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2007.06.010 · Cited by 39
Quantitative Detection of Bioassays with a Low‐Cost Image‐Sensor Array for Integrated Microsystems
Vykoukal, D. M., Stone, G. P., Gascoyne, P. R. C., Alt, E., & Vykoukal, J. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901814 · Cited by 28
Reprint of 'Evaluating organophosphate poisoning in human serum with paper'
Yen, T., Chen, K., Hsu, M., Fan, S.-T., Huang, Y., Chang, C., Wang, Y.-P., & Cheng, C. (2015) · Talanta · doi:10.1016/j.talanta.2015.09.041 · Cited by 8
Morbioli, G. G. (2015) · doi:10.11606/d.75.2015.tde-23062015-105938 · Cited by 4
Self-citation
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Beyond the lateral flow assay: A review of paper-based microfluidics
Carrell, C., Kava, A., Nguyen, M., Menger, R., Munshi, Z., Call, Z., Nussbaum, M., & Henry, C. (2019) · Microelectronic Engineering · doi:10.1016/j.mee.2018.12.002 · Cited by 336
Electrochemical paper-based devices: sensing approaches and progress toward practical applications
Noviana, E., McCord, C. P., Clark, K. M., Jang, I., & Henry, C. S. (2020) · Lab on a Chip · doi:10.1039/c9lc00903e · Cited by 321
Metadata
- Authors
- Morbioli, G. G., Mazzu-Nascimento, T., Stockton, A. M., & Carrilho, E.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2017-06
- Volume
- 970
- Pages
- 1-22
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2601303661
- Cited by
- 434
- References
- 78
- FWCI
- 16.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.