Glucose detection through surface-enhanced Raman spectroscopy: A review
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Glucose detection is of vital importance to diabetes diagnosis and treatment. Optical approaches in glucose sensing have received much attention in recent years due to the relatively low cost, portable, and mini-invasive or non-invasive potentials. Surface enhanced Raman spectroscopy (SERS) endows the benefits of extremely high sensitivity because of enhanced signals and specificity due to the fingerprint of molecules of interest. However, the direct detection of glucose through SERS was challenging because of poor adsorption of glucose on bare metals and low cross section of glucose. In order to address these challenges, several approaches were proposed and utilized for glucose detection through SERS. This review article mainly focuses on the development of surface enhanced Raman scattering based glucose sensors in recent 10 years. The sensing mechanisms, rational design and sensing properties to glucose are reviewed. Two strategies are summarized as intrinsic sensing and extrinsic sensing. Four general categories for glucose sensing through SERS are discussed including SERS active platform, partition layer functionalized surface, boronic acid based sensors, and enzymatic reaction based biosensors. Finally, the challenges and outlook for SERS based glucose sensors are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Danaei, G., Finucane, M. M., Lu, Y., Singh, G. M., Cowan, M. J., Paciorek, C. J., Lin, J. K., Farzadfar, F., Khang, Y.-H., Stevens, G. A., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60679-x · Cited by 3,568
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137 · cited 1×
“For blood glucose monitoring, electrochemical based test strips and meter systems are the common methods [5,6].”
MethodToward a Glucose Biosensor Based on Surface-Enhanced Raman Scattering
Shafer-Peltier, K. E., Haynes, C. L., Glucksberg, M. R., & Van Duyne, R. P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028255v · Cited by 653 · cited 3×
“direct detection of glucose using surface-enhanced Raman spectroscopy [32].”
BackgroundMethodInfluentialYonzon, C. R., Haynes, C. L., Zhang, X., Walsh, & Van Duyne, R. P. (2004) · Analytical Chemistry · doi:10.1021/ac035134k · Cited by 376
Kong, K. V., Lam, Z., Lau, W. K. O., Leong, W. K., & Olivo, M. (2013) · Journal of the American Chemical Society · doi:10.1021/ja409230g · Cited by 173 · cited 2×
“[78] Bimetallic film over nanospheres 4-MPBA/Os-BA 0.”
Kong, K. V., Ho, C. J. H., Gong, T., Lau, W. K. O., & Olivo, M. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.12.062 · Cited by 81 · cited 1×
“This group later did a similar work, where alkyne structures featured as a secondary receptor with a distinct Raman peak at 1996 cm 1 [79].”
BackgroundJiang, L., Wang, L., Zhan, D.-S., Jiang, W.-R., Fodjo, E. K., Hafez, M. E., Zhang, Y.-M., Zhao, H., Qian, R.-C., & Li, D.-W. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112918 · Cited by 41 · cited 1×
“With the two-step approach, a variety of molecules (A in Equation (3)) were exploited such as Leucomalachite green (LMG) [34,87], 3-MPBA [88e90], 4-MPBA [91] 4-mercaptobenzoic acid [92], PATP [35,93,94], 3,305,50-tetramethylbenzidine (TMB) [95,96], Osmium clusters [97,98], 2-mercaptohydroquinone (2-MHQ) [99].”
Method
Metadata
- Authors
- Sun, X.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2022-05
- Volume
- 1206
- Pages
- 339226
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W3211023445
- Cited by
- 161
- References
- 7
- FWCI
- 4.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.