Cited by 222Tissue Engineering and Regenerative MedicineCardiac electrophysiology and arrhythmiasPluripotent Stem Cells Research

Engineered heart tissue models from hiPSC-derived cardiomyocytes and cardiac ECM for disease modeling and drug testing applications

Goldfracht, Idit, Efraim, Yael, Shinnawi, Rami, Kovalev, Ekaterina, Huber, Irit, Gepstein, Amira, Arbel, Gil, Shaheen, Naim +4 more·2019·Acta Biomaterialia

Abstract

Cardiac tissue engineering provides unique opportunities for cardiovascular disease modeling, drug testing, and regenerative medicine applications. To recapitulate human heart tissue, we combined human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) with a chitosan-enhanced extracellular-matrix (ECM) hydrogel, derived from decellularized pig hearts. Ultrastructural characterization of the ECM-derived engineered heart tissues (ECM-EHTs) revealed an anisotropic muscle structure, with embedded cardiomyocytes showing more mature properties than 2D-cultured hiPSC-CMs. Force measurements confirmed typical force-length relationships, sensitivity to extracellular calcium, and adequate ionotropic responses to contractility modulators. By combining genetically-encoded calcium and voltage indicators with laser-confocal microscopy and optical mapping, the electrophysiological and calcium-handling properties of the ECM-EHTs could be studied at the cellular and tissue resolutions. This allowed to detect drug-induced changes in contraction rate (isoproterenol, carbamylcholine), optical signal morphology (E-4031, ATX2, isoproterenol, ouabin and quinidine), cellular arrhythmogenicity (E-4031 and ouabin) and alterations in tissue conduction properties (lidocaine, carbenoxolone and quinidine). Similar assays in ECM-EHTs derived from patient-specific hiPSC-CMs recapitulated the abnormal phenotype of the long QT syndrome and catecholaminergic polymorphic ventricular tachycardia. Finally, programmed electrical stimulation and drug-induced pro-arrhythmia led to the development of reentrant arrhythmias in the ECM-EHTs. In conclusion, a novel ECM-EHT model was established, which can be subjected to high-resolution long-term serial functional phenotyping, with important implications for cardiac disease modeling, drug testing and precision medicine. STATEMENT OF SIGNIFICANCE: One of the main objectives of cardiac tissue engineering is to create an in-vitro muscle tissue surrogate of human heart tissue. To this end, we combined a chitosan-enforced cardiac-specific ECM hydrogel derived from decellularized pig hearts with human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) from healthy-controls and patients with inherited cardiac disorders. We then utilized genetically-encoded calcium and voltage fluorescent indicators coupled with unique optical imaging techniques and force-measurements to study the functional properties of the generated engineered heart tissues (EHTs). These studies demonstrate the unique potential of the new model for physiological and pathophysiological studies (assessing contractility, conduction and reentrant arrhythmias), novel disease modeling strategies ("disease-in-a-dish" approach) for studying inherited arrhythmogenic disorders, and for drug testing applications (safety pharmacology).

Integrity signals

Registry

Crossref · 10.1016/j.actbio.2019.05.016

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Conventional EHTs typically consist of a strip of cardiac tissue formed around straight elastomeric supports or wires.

    “These in vitro models typically consist of a strip of cardiac tissue formed around straight elastomeric supports or wires (Goldfracht et al., 2019;Nunes et al., 2013), consequently lacking the cavity that is necessary for fluid pumping function.”

    From A human engineered mini-heart platform for mimicking ventricular pump function (2025) · cites this paper as Goldfracht et al., 2019

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Goldfracht, I., Efraim, Y., Shinnawi, R., Kovalev, E., Huber, I., Gepstein, A., Arbel, G., Shaheen, N., Tiburcy, M., Zimmermann, W. H., Machluf, M., & Gepstein, L.
Affiliations
  • Technion – Israel Institute of Technology (IL)
  • Universitätsmedizin Göttingen (DE)
Corresponding author
Gepstein, Lior
Venue
Acta Biomaterialia
Publisher
Elsevier BV
Published
2019-07
Volume
92
Pages
145-159
ISSN
1742-7061 (ISSN-L)
OpenAlex
W2944700506
Cited by
222
References
10
Citations by year
2026: 19 · 2025: 29 · 2024: 41 · 2023: 37 · 2022: 35 · 2021: 30 · 2020: 29 · 2019: 2
FWCI
22.93
Type
journal article
Language
en
Open access
closed
Locations
  • Acta Biomaterialia (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Pluripotent Stem Cells Research
Keywords
engineered heart tissue, hiPSC-derived cardiomyocytes, chitosan, disease modeling, drug-induced arrhythmia, long QT syndrome, catecholaminergic polymorphic ventricular tachycardia, reentrant arrhythmias, calcium handling, optical mapping, genetically encoded calcium indicators, voltage indicators
MeSH terms
Action Potentials, Animals, Arrhythmias, Cardiac, Calcium, Cardiovascular Agents, Disease Models, Animal, Drug Evaluation, Preclinical, Extracellular Matrix, Heart, Humans, Models, Cardiovascular, Myocardial Contraction, Organ Specificity, Swine, Hydrogels, Tissue Engineering, Myocytes, Cardiac, Induced Pluripotent Stem Cells

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review